background image

Wiring Diagram 

 

Service Specifications 

April 2004 

16023133 

April 2004 

16023133 

© 2004 Maytag Services 

 

 

© 2004 Maytag Services 

 

!

WARNING

!

WARNING

 

 

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before 

servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires 
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. 

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before 
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires 
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. 

 

 

See Note below 
about alternate wiring 
of Refrigerator door harness 

Service Test 1 

 Defrost Thermostat & Defrost Circuit Test 

When selected this test will display the state of the defrost thermostat. In order to perform this test the defrost heater will 
be energized. The test is activated and deactivated using the Refrigerator Up 

 

 key. Once activated, this test must be 

de-activated to move to another test number. The Freezer Up

 

 / Down 

 

 keys allow selection of the test to be 

performed. 

Note

: When energy switch is in the “Off” position the fresh food mullion heater is energized and when the 

energy switch is in the “On” position the fresh food mullion heater is not powered. To avoid moisture from 
condensing on the fresh food mullion the energy switch should always be in the “Off” position. 

This test also allows observation and measurement of proper defrost function. You can observe defrost heat and voltages 
while the test is activated. 

 

Freezer Refrigerator

 

 

DEFROST THERMOSTAT OPEN 

Freezer Refrigerator

 

1

 

DEFROST THERMOSTAT SHORTED (CLOSED) 

Service Test 2 – Compressor/Condenser Fan Test 

When selected and activated this test will operate the Compressor/Condenser Fan circuit. You should evaluate proper 
operation of the compressor and condenser fan.

 

The Refrigerator Up 

 

 key will toggle between “O” / “F” (ON & OFF) 

the compressor drive circuit. The test must be “deactivated” or in the OFF position to move to another test selection. 

 

Freezer Refrigerator

2

 

 

2

Freezer Refrigerator

 

OBSERVE COMPRESSOR & CONDENSER FAN FUNCTION 

Service Test 3 – Evaporator/Freezer Fan Test 

When selected and activated this test will operate the freezer fan.  The Refrigerator Up 

 

 key will toggle between “O” / 

“F” (ON & OFF) the fan drive circuit.  You will have to inspect the fan for proper function. The test must be “deactivated” or 
in the OFF position to move to another test selection. 

 

Freezer

3

 Refrigerator

 

 

3

Freezer Refrigerator

 

OBSERVE FAN OPERATION 

 

Note: 

In the event of excessive moisture on fresh food door mullion. The red and blue cabinet wires to door 

harness can be reversed to power fresh food door mullion heater continuously. This will help to reduce 
moisture on fresh food door mullion. See wiring alternate above for wiring in mullion heater for continuous 
operation. When powered continuously Energy Switch is no longer in heater circuit. 

 

Содержание AFD2535DEB

Страница 1: ...or Center Compartment Average Food Temperature 3 F Freezer Compartment Average Food Temperature 3 F Ambient F 70 90 110 70 90 110 70 90 110 70 90 110 70 90 110 25 cu ft 1 0 1 60 2 3 28 48 65 35 39 25 38 36 35 0 0 0 or L 7 Once the desired mode is displayed confirm the forced defrost by pressing the Refrigerator down Key once The defrost will begin immediately and the display will return to a norma...

Страница 2: ... PE to confirm entry into the programming mode Freezer Refrigerator P E 4 Entry is confirmed by pressing the Freezer Down key once more Note All control functions will be turned off Compressor Defrost Evaporator Fan the damper will remain in its current position 5 The control will display the current Program Code This value should be validated with the Program Code printed on the unit serial plate...

Страница 3: ...ter is not powered To avoid moisture from condensing on the fresh food mullion the energy switch should always be in the Off position This test also allows observation and measurement of proper defrost function You can observe defrost heat and voltages while the test is activated 1 Freezer Refrigerator O DEFROST THERMOSTAT OPEN Freezer Refrigerator 1 S DEFROST THERMOSTAT SHORTED CLOSED Service Tes...

Страница 4: ...sconnect unit from power before servicing unless tests require power Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization Service Test 6 Open Damper Test When selected this test will indicate the current position O C OPEN CLOSED of the refrigerator damper The Refrigerato...

Отзывы: