Component Specifications
Service Specifications
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Programming Mode:
Component
Specifications all parts
115VAC/60HZ unless noted
Compressor run capacitor
Volt.....................................................
Capacitance ......................................
220 VAC
15
µ
fd
±
10%
Compressor BTUH .................................................
Watt ...................................................
Current Lock rotor..............................
Current Full load ................................
Resistance Run windings ..................
Resistance Start windings .................
730 BTUH
60 Hz / 125 watts
19.0 amps
±
15%
1.09 amps
±
15%
3.33 ohms
±
15%
4.28 ohms
±
15%
Electric damper control
Maximum closing time
Temperature Rating
RPM
36 seconds
20
°
F- 110
°
F
1
Thermistor
Temperature
77
°
F....................................................
36
°
F ...................................................
0
°
F......................................................
Resistance
10,000 ohms
29,500 ohms
86,300 ohms
Condenser motor
Rotation (facing end opposite shaft)
RPM
Watt....................................................
Current ...............................................
Clockwise
1250 RPM
4.2 watts
±
15%@115VAC
0.63 amps
±
15%@115VAC
Evaporator fan motor
Rotation (facing end opposite shaft)
RPM……………………………………
Watt…………………………………….
Clockwise
2940 RPM
4.6
±
15% watts@115VAC
Overload/Relay
Ult. trip amps @ 158°F (70°C) ...........
Close temperature ...........................
Open temperature............................
Short time trip (seconds)....................
Short time trip (amps @77°F (25°C)..
2.67 amps
±
15%
142°F ±16°
284°F ±9°
10 seconds
±
5
11 amps
±
2amps
Control board
Volt.....................................................
See Control Board section for
diagnostics
120VAC, 60 HZ
Thermostat (Defrost)
Volt ....................................................
Watt ...................................................
Current ...............................................
Resistance across terminals:
Above 42°F ±5°..................................
Below 12°F ±7° ..................................
120/240 VAC
495 watts
10/5 amps
Open
Closed
Evaporator heater
Volt.....................................................
Wattage..............................................
Resistance .........................................
115 VAC
435
±
5% watts @ 115VAC
29
±
5% ohms
Mullion Assembly w/ Heater
Volt………………………………………
Wattage..............................................
Resistance .........................................
120 VAC
10
±
.5 watts @ 120VAC
1440
±
5% ohms
Resistance checked at leads at center of hinged side of Fresh
Food door.
Water valve, dual
Volt………………………………………
Watt....................................................
120 VAC
35 watts (Brown coil)
20 watts (Yellow coil)
Light switch
Type……………………………………..
Volt………………………………………
Current…………………………………..
SPST NC
125/250 VAC
8 / 6 amps
Light switch / Interlock
Type……………………………………..
Volt………………………………………
Current…………………………………..
SPDT NO/NC
125/250 VAC
5 / 2.5 amps
Energy Saver switch
Type……………………………………..
Volt………………………………………
Current…………………………………..
SPST NO
125/250 VAC
16 / 8 amps
Note:
The Program Code is located on the Serial Plate on this unit after the word Code.
1. Open the Fresh Food door and hold the Fresh Food door light switch closed while pushing the Freezer
Temperature Down
Key pad 3 times consecutively.
Note:
The 3 Keystrokes must be done consecutively and within 10 seconds.
2. Release the Fresh Food door light switch.
3. The control will display PE to confirm entry into the programming mode.
Freezer Refrigerator
P
E
4. Entry is confirmed by pressing the Freezer Down
key once more.
Note:
All control functions will be turned off (Compressor, Defrost, Evaporator Fan, the damper will
remain in its current position)
5. The control will display the current Program Code. This value should be validated with the Program Code
printed on the unit serial plate.
2
Freezer Refrigerator
5
Note:
If the Program Code is correct, the Programming Mode is exited by closing the Refrigerator door(s).
6. To set the desired Program Code number press the Freezer and Refrigerator UP
keys. The
corresponding digit will be advanced with each key press.
7. Once the desired Program Code is displayed, press the Freezer DOWN
Key until the Program Code
begins flashing indicating it has been saved.
Note:
If you attempt to enter an invalid Program Code the control will not save the new code, but will flash the old
code and this will be displayed. (The unit will NOT run with a Program Code of 00).
8. Once the Program Code has been saved the Programming Mode is exited by closing the Refrigerator
door(s). If the new code is incorrect this process should be repeated after closing the Refrigerator door(s).
The Programming mode can be exited at any time by closing the Refrigerator Door(s).
Defrost Operation:
The Control Board adapts the compressor run time between defrosts
to achieve optimum defrost intervals by
monitoring the length of time the defrost heater is on.
After initial power up, defrost interval is 4 hours compressor run time. Defrost occurs immediately after the 4 hours.
Note:
Once unit is ready to defrost there is a 4 minute wait time prior to the beginning of the defrost cycle.
Optimum defrost is 15 minutes. Each additional minute the defrost thermostat remains closed, 1 hr. is subtracted from
the previous defrost interval. Each minute the thermostat opens prior to optimum defrost, it extends the next defrost
interval 1 hr. When defrost thermostat opens there is a 4-6 minute drip time before compressor restarts or Control
Board will terminate defrost at 25 minutes if defrost thermostat has not opened and will reset the defrost interval to the
8 hr. minimum setting.
4 hours of continuous compressor run resets the next defrost interval to 8 hours and will initiate a defrost, if 8 hours of
compressor run time has also occurred.
Forced Defrost Mode:
Power up
Refrigeration mode will occur unless both the cold control and defrost terminator are open, in that case the
defrost mode will occur for 2 minutes.
The forced defrost function is performed using the refrigerator display and keypad. Enter the Forced Defrost
Mode by performing the following sequence of events:
1. Hold the refrigerator door light switch closed.
2. Press the Refrigerator Temperature Down
keypad 3 times consecutively.
Note:
The 3 keystrokes must be consecutive and within 10 seconds.
April 2004
2
16023133