Component Specifications 

Service Specifications

 

!

WARNING

 

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before 

servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires 
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. 

!

WARNING

 

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before 
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires 
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. 

Programming Mode: 

 

Component 

Specifications all parts 
115VAC/60HZ unless noted 

 

Compressor run capacitor 

Volt.....................................................  
Capacitance ......................................  

220 VAC 
15 

µ

fd 

±

 10% 

Compressor BTUH .................................................

Watt ...................................................  
Current Lock rotor..............................  
Current Full load ................................  
Resistance Run windings ..................  
Resistance Start windings .................  

 

730 BTUH 
60 Hz / 125  watts 
19.0 amps

±

 15% 

1.09 amps

±

 15% 

3.33 ohms

±

 15% 

4.28 ohms

±

 15% 

Electric damper control 

Maximum closing time 
Temperature Rating 
RPM 

36 seconds 
20

°

F- 110

°

Thermistor 

 

Temperature
77

°

F....................................................  

36

°

F ...................................................  

0

°

F......................................................  

Resistance 
10,000 ohms 
29,500 ohms 
86,300 ohms 

Condenser motor 

Rotation (facing end opposite shaft) 
RPM 
Watt....................................................  
Current ...............................................  

Clockwise 
1250 RPM 
4.2 watts

±

15%@115VAC 

0.63 amps

±

 15%@115VAC 

Evaporator fan motor 

Rotation (facing end opposite shaft)  
RPM…………………………………… 
Watt……………………………………. 

Clockwise  
2940 RPM 
4.6 

±

15% watts@115VAC 

Overload/Relay 

Ult. trip amps @ 158°F (70°C) ...........  
  Close temperature ...........................  
  Open temperature............................  
Short time trip (seconds)....................  
Short time trip (amps @77°F (25°C)..  

2.67 amps

±

 15% 

142°F ±16° 
284°F ±9° 
10 seconds 

±

11 amps 

±

2amps 

Control board 

Volt.....................................................  
See Control Board section for 
diagnostics 

120VAC, 60 HZ 

Thermostat (Defrost) 

Volt ....................................................  
Watt ...................................................  
Current ...............................................  
Resistance across terminals: 
Above 42°F ±5°..................................  
Below 12°F ±7° ..................................  

120/240 VAC 
495 watts 
10/5 amps 
 
Open 
Closed 

Evaporator heater  

Volt.....................................................  
Wattage..............................................  
Resistance .........................................  

115 VAC 
435 

±

5% watts @ 115VAC 

29 

±

5% ohms 

Mullion Assembly w/ Heater 

Volt……………………………………… 
Wattage..............................................  
Resistance .........................................  

120 VAC 
10

±

.5 watts @ 120VAC 

1440 

±

5% ohms 

Resistance checked at leads at center of hinged side of Fresh 
Food door. 

Water valve, dual 

Volt……………………………………… 
Watt....................................................  

120 VAC 
35 watts (Brown coil) 
20 watts (Yellow coil) 

Light switch 

Type…………………………………….. 
Volt……………………………………… 
Current………………………………….. 

SPST NC 
125/250 VAC 
8 / 6 amps 

Light switch / Interlock 

Type…………………………………….. 
Volt……………………………………… 
Current………………………………….. 

SPDT NO/NC 
125/250 VAC 
5 / 2.5 amps 

Energy Saver switch 

Type…………………………………….. 
Volt……………………………………… 
Current………………………………….. 

SPST NO 
125/250 VAC 
16 / 8 amps 

Note: 

The Program Code is located on the Serial Plate on this unit after the word Code. 

1. Open the Fresh Food door and hold the Fresh Food door light switch closed while pushing the Freezer 

Temperature Down 

 

 Key pad 3 times consecutively. 

Note:

 The 3 Keystrokes must be done consecutively and within 10 seconds. 

2. Release the Fresh Food door light switch. 
3. The control will display PE to confirm entry into the programming mode. 

 

Freezer Refrigerator

 

 

4. Entry is confirmed by pressing the Freezer Down 

 key once more. 

Note: 

All control functions will be turned off (Compressor, Defrost, Evaporator Fan, the damper will  

remain in its current position) 

5. The control will display the current Program Code. This value should be validated with the Program Code 

printed on the unit serial plate. 

 

Freezer Refrigerator

 

Note: 

If the Program Code is correct, the Programming Mode is exited by closing the Refrigerator door(s). 

 

6. To set the desired Program Code number press the Freezer and Refrigerator UP 

 keys. The 

corresponding digit will be advanced with each key press. 

7. Once the desired Program Code is displayed, press the Freezer DOWN 

 

 Key until the Program Code 

begins flashing indicating it has been saved. 

Note:

 If you attempt to enter an invalid Program Code the control will not save the new code, but will flash the old 

code and this will be displayed. (The unit will NOT run with a Program Code of 00). 

8.  Once the Program Code has been saved the Programming Mode is exited by closing the Refrigerator 

door(s). If the new code is incorrect this process should be repeated after closing the Refrigerator door(s). 

The Programming mode can be exited at any time by closing the Refrigerator Door(s). 

Defrost Operation: 

The Control Board adapts the compressor run time between defrosts

 

to achieve optimum defrost intervals by 

monitoring the length of time the defrost heater is on. 

After initial power up, defrost interval is 4 hours compressor run time. Defrost occurs immediately after the 4 hours. 

Note:

 Once unit is ready to defrost there is a 4 minute wait time prior to the beginning of the defrost cycle.  

Optimum defrost is 15 minutes. Each additional minute the defrost thermostat remains closed, 1 hr. is subtracted from 
the previous defrost interval. Each minute the thermostat opens prior to optimum defrost, it extends the next defrost 
interval 1 hr. When defrost thermostat opens there is a 4-6 minute drip time before compressor restarts or Control 
Board will terminate defrost at 25 minutes if defrost thermostat has not opened and will reset the defrost interval to the 
8 hr. minimum setting. 
4 hours of continuous compressor run resets the next defrost interval to 8 hours and will initiate a defrost, if 8 hours of 
compressor run time has also occurred. 

Forced Defrost Mode: 

Power up  

Refrigeration mode will occur unless both the cold control and defrost terminator are open, in that case the 

defrost mode will occur for 2 minutes. 

The forced defrost function is performed using the refrigerator display and keypad. Enter the Forced Defrost 
Mode by performing the following sequence of events: 

1.  Hold the refrigerator door light switch closed. 

 

2.  Press the Refrigerator Temperature Down 

 keypad 3 times consecutively. 

Note:

 The 3 keystrokes must be consecutive and within 10 seconds. 

April 2004 

16023133 

April 2004 

16023133 

© 2004 Maytag Services 

 

 

© 2004 Maytag Services 

Содержание AFD2535DEB

Страница 1: ...or Center Compartment Average Food Temperature 3 F Freezer Compartment Average Food Temperature 3 F Ambient F 70 90 110 70 90 110 70 90 110 70 90 110 70 90 110 25 cu ft 1 0 1 60 2 3 28 48 65 35 39 25 38 36 35 0 0 0 or L 7 Once the desired mode is displayed confirm the forced defrost by pressing the Refrigerator down Key once The defrost will begin immediately and the display will return to a norma...

Страница 2: ... PE to confirm entry into the programming mode Freezer Refrigerator P E 4 Entry is confirmed by pressing the Freezer Down key once more Note All control functions will be turned off Compressor Defrost Evaporator Fan the damper will remain in its current position 5 The control will display the current Program Code This value should be validated with the Program Code printed on the unit serial plate...

Страница 3: ...ter is not powered To avoid moisture from condensing on the fresh food mullion the energy switch should always be in the Off position This test also allows observation and measurement of proper defrost function You can observe defrost heat and voltages while the test is activated 1 Freezer Refrigerator O DEFROST THERMOSTAT OPEN Freezer Refrigerator 1 S DEFROST THERMOSTAT SHORTED CLOSED Service Tes...

Страница 4: ...sconnect unit from power before servicing unless tests require power Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization Service Test 6 Open Damper Test When selected this test will indicate the current position O C OPEN CLOSED of the refrigerator damper The Refrigerato...

Отзывы: