![Amada TC-W100A Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/amada/tc-w100a/tc-w100a_operation-manual_2915854022.webp)
CHAPTER 2: INSTALLATION
TC-W100A - THERMOCOUPLE WELDER
2-4
990-070
Handpiece – Wire Clamping Jaws Installation
Wire Clamp Jaw Removal and Insertion
Loosen the set screws that hold each Wire Clamp Jaw in place. Pull each jaw straight out of the
Handpiece. See figure 2-2.
To replace the Upper Wire Clamp Assembly, open the Handpiece by sliding the black Loading Button
back toward the square part of the Handpiece. Insert the Wire Clamp Jaw, CONTAINING THE GUIDE
TUBE, into the upper half of the Handpiece. Line up the flat wedge shaped face on the Wire Clamp Jaw
with the flat surface on the upper Handpiece face. Tighten the set screw.
To replace the Lower Wire Clamp Assembly, insert the remaining Wire Clamp Jaw into the lower half
of the Handpiece. Line up the flat wedge shaped face on the Wire Clamp Jaw with the flat surface on
the upper Handpiece face. Tighten the set screw. Close the Handpiece by sliding the black Loading
Button forward. Both halves should be flush at the tip when the tip is closed.
Do not mix Wire Clamp sets. The identification code on the upper Wire Clamp Jaw must match the
identification code on the lower Wire Clamp Jaw.
Figure 2-2. Wire Clamp Jaw Assembly
Handpiece
Body
Lower Setscrew
Align Here
Lower Wire
Clamp Jaw
Upper Wire
Clamp Jaw
Upper Setscrew
Align Here
Содержание TC-W100A
Страница 1: ...THERMOCOUPLE WELDER TC W100A OPERATION MANUAL 990 070 Rev H...
Страница 12: ......
Страница 18: ......
Страница 30: ...AMADA WELD TECH INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...