4. Reading the Measured Value 

4-3 

 

  (3) Reading the Measured Value 

 

  Security Setting of Microsoft Excel 

Since the 

MA-716A

 uses the macro function of Microsoft Excel, the 

security

*1

 setting of Microsoft Excel 2003 is required. 

 

Select Tool 

 Macro 

 Security from the menu bar. Set the security level to 

Middle 

*2

 or Low 

*3

 

*1

 When the security level is set to Middle or Low, defense against a virus 

using the macro function weakens. Use software for virus so that it does 
not cause any trouble if a virus invades macro. 

 

*2

 When the security level is set to Middle, a warning message for macro 

appears when you open a file. 

 

*3

 When the security level is set to Low, a warning message does not appear. 

If a file which is not using macro is infected by a virus, a warning 
message is not displayed. 

 

 Opening a File 

Open the file copied in 

Chapter 4 (2)

 on Microsoft Excel. 

*4

 

When the security level is set to Middle, a warning message for macro 
appears when you open a file. Select Validate Macro. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 (Remarks) 

(a) Start 

(Starts reading the measured value) 

(b) Stop 

(Stops reading the measured value) 

(c)  End 

(Ends the measured-value-reading software) 

(d) Restart 

(Restarts the measured-value-reading software) 

 

*4

 For how to open files, see the operation manual for Microsoft Excel. 

(d) 

(a) 

(b) 

(c) 

Содержание MM-122A

Страница 1: ...U02M0697E 04 OPERATION MANUAL COMMUNICATION SOFTWARE FOR MM 122A MA 716A...

Страница 2: ...rior to use Store appropriately for ready reference Contents 1 Features 1 1 2 System Requirements 2 1 3 Connection 3 1 to 6 4 Reading the Measured Value 4 1 to 4 5 Changing the Setting 5 1 to 6 Micros...

Страница 3: ...on The MM 122A can be connected easily to PC using the MA 716A The connecting cable is optional Reading the measured data The value measured on MM 122A can be read in PC Changing the setting Each sett...

Страница 4: ...C is required 1GHz or higher CPU and 1GB or larger memory are recommended Hard Disk 10MB or larger space Serial Port At least one communication port for RS 232C and RS 485 Microsoft Excel Microsoft Ex...

Страница 5: ...er is not displayed on screen open My Computer For how to open My Computer see the operation manual for the operation system you use 2 When My Computer is opened double click the drive into which Setu...

Страница 6: ...MA 716A 3 Connection 3 2 7 When the setting screen for program group is opened click Continue 8 When the end screen is displayed click OK to end the setup...

Страница 7: ...y for the setting change or 232Fr for the measured value reading RS 485 Up to thirty one MM 122As can be connected when the communication method of the MM 122A is set to 485Sy for the setting change W...

Страница 8: ...to 232Fr When connecting with RS 485 set to 485Fr Set the transmission rate to 9600bps For details see the operation manual for the MM 122A ATTENTION Do not assign one number to more than one device...

Страница 9: ...king software f Clear Clears display Setting the Checking Software Set the communication port No and the transmission rate Set the communication port No connected with the communication cable for Comm...

Страница 10: ...Communication and the received data is displayed for each item of Data When communication is not made normally Nothing or ERROR is displayed for Communication Check the communication cable connection...

Страница 11: ...ssion Rate and current setting to be measured are the same settings as the MM 122A Example Current setting to be measured AC Transmission Rate 9600bps Communication Port No COM2 When the settings are...

Страница 12: ...2 xls Communication Port 3 excel_receive transister mode mon_tr_96_com3 xls Communication Port 4 excel_receive transister mode mon_tr_96_com4 xls When Transmission Rate is 19200bps Communication Port...

Страница 13: ...security level is set to Middle a warning message for macro appears when you open a file 3 When the security level is set to Low a warning message does not appear If a file which is not using macro i...

Страница 14: ...Step end 6 No current error 6 Pulsation error 6 5 The result of judgment is NOMAL N LOW L HIGH H or No Judgment S P space 6 NG is displayed when a trouble occurs Stopping reading the measured value P...

Страница 15: ...smission Rate and current setting to be measured are the same settings as the MM 122A Example Transmission Rate 9600bps Communication Port No COM1 When the settings are as above copy excel_schchange s...

Страница 16: ...e security level is set to Low a warning message does not appear If a file not using macro is infected by a virus a warning message is not displayed Opening a File Open the file copied in Chapter 5 2...

Страница 17: ...on the system setting screen reads the system settings from the MM 122A Read button on the schedule setting screen reads the schedule specified as system setting from the MM 122A Writing to the MM 12...

Страница 18: ...system setting screen Remarks a Measurement method b Measurement frequency c Cool time d No measurement time e Trigger level f Print g Communication Not changeable h Communication Speed Not changeable...

Страница 19: ...lect Schedule setting tab to display the schedule setting screen a Schedule No b RMS current c PEAK current d Current Upper limit e Current Lower limit f Current range g PEAK RMS h TP TH i Pulsation j...

Страница 20: ...MA 716A 5 Changing the Setting 5 6 Initializing Method Select Default setting tab and press Default button to initialize the settings Remarks a Default Initializes settings a...

Отзывы: