10.1.8 Checking the oil level in the spur gear trough
INTERVAL
After initial operation
Every 50 operating hours
or
weekly
IMPORTANT
Damage due to impurities in the spur gear
trough
Clean the implement before performing
maintenance.
1.
Park the implement on a horizontal surface.
2.
Loosen and remove the nut
2
.
3.
Remove the cover bolt
1
.
4.
Remove the cover with ventilation pipe
4
.
NOTE
If oil types are mixed, warranty claims cannot be
accepted.
Do not mix oils.
Fill with new and clean gear oil.
5.
If the spur gears are not halfway covered with
gear oil in the spur gear trough,
refill oil according to the technical data.
6.
Check the fit of the gasket
3
.
7.
Install the cover with the ventilation pipe.
8.
Install the cover bolt.
9.
Install the nut and tighten it.
NOTE
There is no need to change the oil in the spur
gear trough.
3
1
4
2
CMS-I-00003467
CMS-T-00004838-B.1
10 | Repairing the machine
Maintaining the machine
MG7512-EN-GB | C.1 | 29.09.2022 | © AMAZONE