![AMA KE 6002-2 Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/ama/ke-6002-2/ke-6002-2_original-operating-manual_2915711070.webp)
Hydraulic hose lines must not be more than 6 years
old.
3.
Check the manufacturing date
1
.
CMS-I-00000532
4.
Have any worn, damaged or aged hydraulic
hose lines immediately replaced at a specialist
workshop.
5.
Retighten loose bolted connections.
10.1.4 Checking the tines
INTERVAL
Every 50 operating hours
1.
Determine the length of the tines.
2.
If the minimum length of the tines is undercut,
replace the tines.
150
mm
CMS-I-00003613
CMS-T-00005050-A.1
10 | Repairing the machine
Maintaining the machine
MG7512-EN-GB | C.1 | 29.09.2022 | © AMAZONE