![Alyseum MS-MATRIX Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/alyseum/ms-matrix/ms-matrix_user-manual_2915445010.webp)
MS-MATRIX – User’s manual © - Revision 1.8
Page 10
Pushing the INPUT/SAVE encoder will overwrite the current matrix connections to the
specific location and the previously saved matrix will be lost.
5.4.3
Saving a Preset Automatically
When Auto Save is activated (see paragraph 5.6.2) there is no need for any action in order
to save a Preset as any change made is automatically saved.
This means that by activating or deactivating a connection while in IN/OUT Mode you also
alter the matrix saved on the specific Preset location.
5.5
MIDI / CV Mode
To select the method of loading a Preset:
1. Select MIDI/CV mode (see paragraph 5.2)
2. Turn the INPUT/SAVE encoder to select one of the five
settings: (s
ee Operation Snapshot below).
A.
PGM XX
: Selects Preset by MIDI Program Change
messages (PGM CH) coming from the front panel MIDI port
(XX = MIDI channel 1 to16)
B.
NOTE XX
: Selects Preset by MIDI Note On messages
incoming from the front panel MIDI port (XX = MIDI channel
1 to 16)
C.
CV FR
: Selects Preset by CV coming from the front panel
input labeled CV (0 to +5 Volts)
D.
— —
: Selects Preset only manually (see paragraph
5.4.1.)
3. Push the INPUT / SAVE encoder to confirm your selection
4. Your selection has been saved as soon as the MIDI/CV Mode LED is turned Off.
When one of the five MIDI/CV Mode settings has been selected any incoming activity,
either from the MIDI IN input or the CV input, will be indicated by the flashing MIDI/CV
Mode LED.
All Preset changes due to midi or analog signals are ignored while IN/OUT Mode,
PRESET Mode or MIDI/CV Mode is active.
PGM 01
PGM 16
NOTE 01
NOTE 16
CV FRONT
__ __