background image

LP2 Surface/Wall Installation Guide

4 of 12 

102-000027 - IG121818-A.0

LUMINAIRE OVERVIEW

Drill
#2 phillips bit

Tools Required

Wire strippers

Input Voltage / Frequency:

See product label

Rated Power:

See product drawing

Ambient Temperature:

-

4° – 120°F (

-

20° – 50°C)

Environment:

Dry and damp locations

Quick Specs

Junction Box (Optional)

Parts (by others)

Wood Screws, #10, 1.5” 

long

Conduit/NM (non-metallic) 

cable (or similar) if not using 

J-Box

OPTIONAL HARDWARE COMPONENTS

Mounting Bracket

J-Box (Optional)

Blocking/Framing

To Building Power (High Voltage)

Wall Mount Plate (Optional)

Fixture Body

(w/ Integrated LED Driver)

Heatsink/Reflector

Lens

5/64” Hex Key (for Joining)
1/8” Hex Key (for Joining)

Содержание LIGHTPLANE 2

Страница 1: ...A 1035 22nd Avenue Unit 1 n Oakland CA 94606 P 510 489 2530 E TalkToUs alwusa com W alwusa com INSTALLATION INSTRUCTIONS LIGHTPLANE 2 LP2SMB W Surface and Wall Mount LED...

Страница 2: ...nuous row mounting 1 Lisez toutes les instructions 2 Installez conform ment la r glementation du code lectrique national et local 3 Ce produit est destin tre install et entretenu par un lectricien agr...

Страница 3: ...818 A 0 Table of Contents Troubleshooting 11 Wiring Diagrams 12 Installation 5 Prepare Ceiling 5 Connecting Multiple Sections 10 SMB Surface Back Mount 5 Wall Mount 7 Luminaire Overview 4 Diagrams 4 C...

Страница 4: ...4 120 F 20 50 C Environment Dry and damp locations Quick Specs Junction Box Optional Parts by others Wood Screws 10 1 5 long Conduit NM non metallic cable or similar if not using J Box OPTIONAL HARDW...

Страница 5: ...se run conduit NM cable to powerfeed location 2 Install Canopy J Box Wiring S A M P L E D R A W I N G Carefully remove lens using suction cup or similar 3 Remove Lens Remove heatsink reflector screws...

Страница 6: ...le Sections If Necessary Please see steps 28 through 33 for directions on connecting multiple sections 8 Raise Fixture to Ceiling Connect Wiring Raise entire fixture to ceiling and connect wiring insi...

Страница 7: ...Mount Carefully remove lens using suction cup or similar 15 Remove Lens WALL ELECTRICAL WIRING A T MUST 1 120V MED 3000K MED 3000K 0 10V 10 EXT R AL 120V NA Follow steps 1 2 to prepare ceiling Instal...

Страница 8: ...ns If Necessary Please see steps 27 through 32 for directions on connecting multiple sections 20 Raise Fixture to Wall Connect Wiring Raise entire fixture to wall and connect wiring inside fixture Ref...

Страница 9: ...6 Turn Power On Re install each heatsink reflector section CAUTION Do not pinch wires while reattaching 22 Re install Heatsink Reflector Re install heatsink reflector screws to attach back to housing...

Страница 10: ...and that there are no gaps between sections 31 Tighten Joiner Screws on Inner Corner Installation Connecting Multiple Sections Tighten joiner set screws as shown using a 5 64 hex key for the sides and...

Страница 11: ...stomer support Only a certified electrician can service and troubleshoot product field issues Always turn main power off before servicing fixture Fixture section s do not illuminate Possible loose low...

Страница 12: ...60Hz DIM DIM 0 10V Dimming Black White Green Clear Black DMX in shield DMX in Line Voltage Hot Line Voltage Neutral Ground L N AC 50 60Hz DMX In Shield DMX in Red DMX in DMX in Clear Black DMX out sh...