LP2 Surface/Wall Installation Guide
LP2 Surface/Wall Installation Guide
7 of 12
102-000027 - IG121818-A.0
Installation: SMB - Surface/Back
Mount (Cont.)
Re-install heatsink/reflector screws to attach back to
housing.
11
Re-install Heatsink/Reflector Screws
Carefully re-install lens, ensuring lens sits properly within
Lens Clips.
12
Re-install Lens
Installation: Wall Mount
Carefully remove lens using suction cup or similar.
15
Remove Lens
WALL
ELECTRICAL WIRING:
A
WALL
T
MUST
1
AL
120V
MED/3000K
MED/3000K-0/10V/10%-EXT/R-AL-120V-NA
Follow steps 1-2 to prepare ceiling. (Install framing, J-Box,
if using, and wiring to J-Box or fixture).
14
Prepare Ceiling
SAMPLE DRAWING
Remove heatsink/reflector screws that attach to housing.
Set aside.
16
Remove Heatsink/Reflector Screws
Turn breaker ON and ensure that fixture operates as
intended and that there are no loose connections.
13
Turn Power On