HB1.25 Wall Mount Installation Guide
8 of 11
102-000018 - IG110218-A.0
11
Connect wiring
Connect wiring quick-connects.
It may require two
people to install joining sections.
12
Mount fixture to wall
14
Secure internal joiner brackets
Using philips screwdriver, fasten internal brackets. Re-
place heat sink and lens.
Position keyholes over mounting screws and slide fixture
down to ensure proper attachment. If fixture does not
slide down, unscrew mounting screw slightly. If fixture is
loose on keyhole, tighten mounting screw slightly.
Installation: Joining Straight Sections
SHOCK HAZARD! May result in serious injury or
death.
Turn power OFF at circuit breaker prior to
installation or servicing.
!
DO NOT PINCH OR PUT EXCESSIVE TENSION ON
WIRES
while joining sections or reattaching end
caps.
10
Prepare structure for connecting fixture
Install blocking, drywall, and mounting screws as dimen-
sioned in submittal drawings. All mounting points must be
level.
13
Remove lens and heat sink
Carefully remove lens and heat sink to access joiner
brackets.