The table below lists the specifications of the main parameters of the OPS-HD-AC: 

 

OPS-HD-AC Specification

 

Input voltage 

100 – 240 VAC 

Input Frequency 

50 – 60 Hz 

Electrical 

Input Current  

1.5 A 

Output Voltage 

55 VDC 

Output 

Output Current 

1.0 A 

Environmental 

Operating Temperature 

-40 to 55 

o

C (-40 – 131 

o

F) 

 

Humidity 

100% Relative Humidity, Condensing  

Mechanical 

Dimensions 

20.3 x 36.7 x 11.5 cm / 8 x 14.5 x 4.5 in 
(excluding mounting plate) 

 

Weight 

(4.4 kg)  9.7 lb 

Safety 

TUV / UL 60950-1, EN 60950-1, CE 

Standard and 
Regulations 

EMC 

FCC Part 15 (Emission) 

 

 

Version Compatibility and Interoperability  

 

The OPS-HD-AC is fully compatible to the IDU that is used with the BreezeACCESS 

VL, BreezeNET B and DS11 (Rev 4.0 and above). 

 

Nevertheless, the OPS-HD-AC will not have the LED indications that are available in 

the regular IDU (Power, Ethernet and Wireless), instead it will have one Power led 

that can be seen under the service box in the RJ-45 connector that is marked: 

‘Radio-1’ 

 

Also the reset button that is available on the regular IDU is not available in the OPS-

HD-AC and the reset can be performed using the management application. 