![Alvarion BreezeNET BU Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/alvarion/breezenet-bu/breezenet-bu_quick-installation-manual_2915188003.webp)
- 3 -
8. Mount the indoor unit and connect the outdoor-to-indoor cable to
its RADIO port. Connect the indoor unit to the AC mains using the
power cord supplied with the unit.
NOTE:
The indoor unit should be connected to the power
source only after it has been connected to the outdoor
unit.
The color codes of the power cord are:
Brown
Phase ~
Blue
Neutral 0
Yellow/green
Grounding
9. Use a straight Ethernet cable to connect the ETHERNET port to a
Hub/Switch. Use a crossed Ethernet cable to connect directly to a
PC’s NIC.
Basic Configuration
1. Initial configuration can be performed either via Telnet or using
the configuration utility.
2. Connect a PC to the Ethernet port, using a crossed cable. The
default IP address is 10.0.0.1.
3. If you use Telnet for initial configuration, run the Telnet program.
Select your permitted access level and enter your password (the
default Installer password is “user”). Access the
Basic
Configuration
menu and configure the basic parameters required
to allow connectivity with the base station and to support remote
management of the unit. In many installations, most of these
parameters should not be changed from their default values. The
following list includes the basic parameters and their default
values:
Basic Configuration
Parameter
Default
Comment
Change Unit Type to
RB (in Unit Control
Menu)
If
necessary.
Reset before
continuing with
configuration.
Ethernet Port
Negotiation Mode
Auto
Negotiation
IP Address
10.0.0.1
Subnet Mask
255.0.0.0
Default Gateway
Address
0.0.0.0
DHCP Option
Disable
Access to DHCP
BU: From
Ethernet Only
RB: From
Wireless Only
ESSID ESSID1