INSTALLATION AND OPERATION MANUAL | CUL11 CONTROL UNIT
10
10
FAULTS AND RECOMMENDATIONS ON ThEIR ELIMINATION
the working area. While operating the leveller, monitor all movements of the leveller. Never
touch moving parts of the leveller. No one should be in the working area of leveller.
Turn the on-off switch
1
(
fig.
1) to the
I
position (‘
ON
’ position) to apply the supply voltage to
the control unit module.
Loading platform control:
•
press and hold
control button
2
(
fig.
1) to lift the platform. When lifting is completed,
release
button and the platform will stop.
•
after releasing
button press and hold
button
3
(
fig.
1) for 2 seconds.
The lip will extend.
Control of
button will be allowed only after control of
button for more than
2 seconds. If
button is pressed after more than 2 seconds since releasing
button, the platform will start lowering automatically. In this case press
button
again for at least 2 seconds for the ramp to restart extension.
button running time (holding)—60 seconds.
button running time (holding)—40 seconds.
•
after the required lip extension, depress
button and after 2 seconds dock leveller
starts automatically lowering in the intermediate position to the vehicle loading level
(floating position—platform follows the movements of vehicle floor).
Returning the leveller to the initial position:
•
in order to return the leveller to the initial position press and hold
control button
2
(
fig.
1) until the leveller lifts and the lip returns into the initial position (retracts back).
•
release
button and after 2 seconds the leveller automatically lowers into the initial
position.
•
switch the on-off switch
1
(
fig.
1) to ‘
0
’ position (‘
OFF
’ position).
The scheduled maintenance of the control unit should be performed as a part of loading equip-
ment service works in strict compliance with the current regulations.
7.
FAULTS AND RECOMMENDATIONS ON ThEIR
ELIMINATION
Fault
Fault
Possible cause
Possible cause
Recommendations
Recommendations
After turning the
switch
1
(
fig.
1) into
I
position,
LED 4
does not light up
No supply voltage
Check the mains voltage. Make sure that the
control unit is connected to the mains (section 4
‘Electric module’). Make sure and replace, if
necessary, the fuses. Check that the jumper is
set at
OUT
+ 24 V and
IN
+ 24 V contacts of J5
connector. Check that
LED 4
is connected
After turning the
switch
1
in
I
position,
LED 4
flashes rapidly
Incorrect mains
connection or low
supply voltage
Check the mains voltage. Check that all wires
of power cable are connected to the unit (no
broken wires). Switch wires for power cable
connection, for example, at
L1
and
L2
contacts
of
J1
connector (ensure the correct phase
sequence)
After turning the
switch
1
in
I
position,
LED 4
flashes rarely.
hL3
LED
lights up
No connection
of valves (valve)
Ensure that valves of the hydraulic unit are
connected