background image

CONNECTION AND OPERATIONAL MANUAL. CONTROL UNIT CUL01

3

3

GENERAL PROvISIONS AND SAfETy MEASURES

1. 

GENERAL PROvISIONS AND SAfETy MEASURES

 

Y

This manual contains important safety information. Read attentively the information 

written below before installation. Keep the manual for further use!

Do not start item installation or operation if you have any questions or you do not understand 

something. If necessary, contact the nearest ALUTECH Group of Companies service department 

or office. Follow the safety measures of the existing normative documents and of this manual. 

Always follow the safety regulations while working.

Skilled and trained specialists must install, plug in, conduct final tests, put into operation and 

service the item.
Item installation, connection, adjustment and operation in violation of rules is prohibited as it 

can lead to breakages, injuries and damage. Item construction elements mustn’t be altered 

or changed and the item mustn’t be misused. Manufacturer and supplier are not responsible 

for the damage due to unapproved item alteration, changing or misuse.
Potential risk degree should be evaluated (collision, squeezing, jamming and other hazards). 

It should decided which additional devices (accessories) are necessary for preventing potential 

risks and following the existing safety rules.

The item must not be used in acid, salty or explosive environments. The item must be far enough 

from a heat source and open fire. If not, the item can be damaged, function improperly, a fire 

can break out or other dangerous situations can happen. There mustn’t be any foreign objects or 

liquids inside during installation or operation, otherwise unplug the item and contact the service 

department. Item operation in such a case is dangerous. The control unit must be mounted with 

cable inlets pointing downwards so as to prevent water from filling its enclosure. 

Turn the power off when carrying out any works (installation, repair, service, cleaning etc.) and 

connecting the item. If the switching unit is out of sight, attach the notice plate: ‘Do not turn on. 

People are working’ and take measures to avoid unsanctioned restoring of the supply. If the power 

cable (power cord) is damaged, it must be replaced by the manufacturer or service department 

specialist. Follow safety measures when using a power cord: 

 •

insert the plug into the socket fully; 

 •

do not pull the cord when you remove the plug from the socket; 

 •

do not a the socket with poor contacts; 

 •

do not touch the plug with wet hands; 

 •

do not damage the power cord, do not twist, bend and stretch it forcibly; 

 •

do not put heavy objects on the power cord and do not place it near hot objects; 

 •

make it easy to reach the socket; 

 •

use only the power cord supplied; 

 •

it is forbidden to use a damaged or defective power cord.

Item installation place must be protected from collisions and impacts; installation surface must 

be strong enough. The control unit must be within sight of the equipment, at a height of not less 

than 1.5 m. Electrical network must be grounded for safety and security. Make sure the system is 

connected and works properly. Electrical network, to which the item is connected, must have a pro-

tection device (16 A circuit breaker). Space between circuit breaker contacts is not less than 3 mm.
Multicore electrical cables parameters (cross section, wire quantity, length etc.) must correspond 

to the connection diagram, item power, laying distance, laying method and external conditions. 

Electrical cables must be protected from coming into contact with rough and sharp surfaces; 

use ribbed, ducting and cable inlets when laying cables. The company has the right to change 

the manual and item construction without any reasonable notice maintaining the same func-

tionality. The instruments must be fault-free and correspond to the existing safety regulations, 

standards and instructions.

Содержание CUL01

Страница 1: ...CONNECTION AND OPERATIONAL MANUAL Control unit CUL01 English 2020 www alutech group com ...

Страница 2: ......

Страница 3: ... that you have made the right choice ALUTECH Group of companies has the right to change and complement item construction and this document without warning CONTENTS 1 General provisions and safety measures 3 2 Item description 4 3 Specifications 4 4 Packaged electronic circuit 5 5 Operation 8 6 Storage tranportation and utilisation 8 7 Warranty 8 8 Certificate of comissioning 9 9 Warranty repair 10...

Страница 4: ......

Страница 5: ...wards so as to prevent water from filling its enclosure Turn the power off when carrying out any works installation repair service cleaning etc and connecting the item If the switching unit is out of sight attach the notice plate Do not turn on People are working and take measures to avoid unsanctioned restoring of the supply If the power cable power cord is damaged it must be replaced by the manu...

Страница 6: ...contents of this manual cannot be used as grounds for legal challenges 2 ITEM DESCRIPTION The control unit is used for SL dock leveller with swing lip with 1 valve hydraulic unit There is a line circuit breaker 1 and control button 2 on the cover of the control unit body pic 1 The dimensions for mounting are also shown on pic 1 in millimetres 1 2 190 280 254 180 Pic 1 CUL01 control unit 3 SPECIFIC...

Страница 7: ...as a packaged electronic circuit installed to which electrical devices are connected pic 2 See the circuit elements list in Table 2 J11 J4 J3 J9 HPT IN W V U L1 L2 L3 N PE PE HPT OUT L1 L2 L3 J8 MOTOR REL1 U8 U9 U10 J7 230V 400V U11 U12 REL2 J10 24V Vent Sens GND GND J1 NPN PNP J12 LED1 J2 2A T 3 6 3A T Pic 2 Packaged electronic circuit ...

Страница 8: ...e jumper must be installed as in pic 2 J8 Line circuit breaker 1 adapters pic 1 pic 2 The plug of 015 3P N E 16A 6h type is used for network connection The socket must be of the same type for the plug using it J9 J10 The adapter of a hydraulic unit valve pic 5 and sectional doors position sensor pic 6 Security sensor supply voltage is 24 V DC If the security sensor has signaled sectional doors are...

Страница 9: ...J11 J4 W V U PE PE M 3 Pic 4 Electric motor connection Y If the platform does not move travel direction does not coincide with the required one when the control button 2 is pushed two electric motor phase wires are to change their positions J10 24V Vent Sens GND GND J10 24V Vent Sens GND GND BN BK BU BN коричневый BK черный BU синий Pic 5 Valve connection Pic 6 Security sensor connection sectional...

Страница 10: ... force in the country of the customer The item does not contain precious metals and substances dangerous for life health and environment Y The package must be utilised in accordance with existing legislation 7 WARRANTY The item works well if it is stored transported adjusted and run according to the existing rules if installation and technical service are provided by the organisation specialising ...

Страница 11: ...e for installation signature print name Consumer Applicant have checked the completeness of the set is aquianted and agrees with warranty conditions and terms has no complaints about the item design The item is installed and adjusted in accordance with the specified requirements and is suitable for operation Safety and operational instruction has been conducted Applicant consumer name address and ...

Страница 12: ...ganisation List of repair works Date of repair LS Responsible for repair signature ________________________________________________________ print name Repair organisation List of repair works Date of repair LS Responsible for repair signature _________________________________________________ print name ...

Страница 13: ...CONNECTION AND OPERATIONAL MANUAL CONTROL UNIT CUL01 11 11 COMMENTS COMMENTS ...

Страница 14: ......

Страница 15: ......

Страница 16: ...Art R7090126 03 2018 10 Selitskogo str 220075 Minsk Republic of Belarus Tel 375 17 330 11 00 Fax 375 17 330 11 01 www alutech group com ...

Отзывы: