8. SETTING OF THE CONTINUOUS OPERATION TIME
Turn on the power of the
control unit.
Set switch 5 to
the “ON” position.
Press the “SUB” or “ADD”
button to set
the time in seconds.
The setting has been saved.
The setting has been saved.
10. PHOTOCELL SETTINGS
9. SETTING THE AUTOMATIC CLOSING TIME
Turn on the power of the
control unit.
Set switch 5 to
the “OFF” position.
Press the “SUB” or “ADD”
button to set
the time in seconds.
Set switch 1 to
the “ON” position.
Set switch 1 to
the “OFF” position.
active photocell
inactive photocell
11. SAFETY EDGE SETTINGS
Set switch 2 to
the “ON” position.
Set switch 2 to
the “OFF” position.
safety edge is active
safety edge is inactive