PROGRAMMING MANUAL FOR THE AC 277-01 CONTROL UNIT
3. TECHNICAL SPECIFICATIONS
4. CONNECTION OF THE TRANSMITTER
Power supply:
Operating temperature:
Maximum output power:
Works exclusively with motors without built-in radio control.
Works with all AC series transmitters included in the ALUPROF S.A. offer.
Possibility to program up to 20 transmitters, Each next transmitter will erase the first one.
230 VAC / 50 Hz
~ -20°C - ~ +55°C
750 W
Frequency:
433.92 MHz
Company reserves the tolerance of catalog data due the different conditions usage.
Average range:
120 meters (in open space), 20 meters (inside buildings)
L
E
N
UP
DOWN
COM
+24
S/STOP
GND
+15
- phase wire
- protective wire
- neutral wire
- UP direction
- DOWN direction
- power connector
- Power supply: +24 V
- STOP
- ground
- Power supply: +15 V
If no external switches are connected to the control unit, you must put the jumper between “STOP” and “GND”.
POWER
MOTOR
PHOTOCELL
MASTER CONTROL
EXT-MANUAL
SAFETY EDGE
- power connectors
- motor connectors
- photocell connectors
- external switch connectors
- external switch connectors
- safety edge connectors