4. Operating
The Air-Control is the central control element of the Compressors.
ENTER
INFO
AIR CONTROL 1
Kompressoren
A
LUP
_
_
_
Automatik
bar
o
C
M
4.1 Display
The display permanently displays the line pressure, final compression
temperature and operating status of the compressor.
Restart
Automatic
Remote
bar
o
C
!
M
Network
pressure
Compressor
temperature
Error number,
Warning number,
Programming level
Symbol Error
Symbol Warning
!
Symbol Motor operates
Symbol Compressor compresses
Symbol Heating on
Automatic restart after power failure
M
Restart
Operation mode „Automatic“
Automatic
Flashing: Operation in „Remote On/Off mode“
Constant: Operation through lead / lag control
Remote
4.2 Key assignment
I
On key
The green lamp flashes: The compressor i ready for use
and may start automatically at any time
The green lamp is lit: The compressor is running
Warning and error display
The red lamp is lit: Compressor error
The red lamp flashes: Warning
O
Stop key
to shut down the compressor (via idling)
for input of codes
for acknowledgement of errors
INFO
Information
can be obtained on the set values by
pressing several times:
1x
Cut-in pressure (bar)
2x
Cut-out pressure (bar)
3x
Safety pressure (bar)
4x
Min. start temperature (5.0 °C)
5x
Max. compressor temperature (110 °C)
6x
Total operating hours (h)
7x
Load hours (h)
8x
Residual service life air filter (h)
9x
Residual service life oil and oil filter (h)
10x Residual service life oil separator (h)
11x Residual service life lubricant (h)
12x Residual service life to service (h)
ENTER
Confirm entered values and parameters
Change values and parameters
Only in case of emergency the system may be shut down with the
EMERGENCY STOP switch.
4.3 Warnings
The red lamp and the symbol
!
are flashing. The corresponding
warning number flashes:
2
High compressor final temperature
3
High network pressure
11
Residual service life air filter < 100 h
12
Residual service life oil/oil filter < 100 h
13
Residual service life oil separator < 100 h
14
Residual service life motor lubrication < 100 h
15
Residual service life to maintenance < 100 h
Realised maintenance have to be acknowledged with Code 21.