background image

(2) Outside of each separate dwelling unit 

sleeping area within 6.4 m (21 ft) of any 

door to a sleeping room, the distance 

measured along a path of travel

(3) On every level of a dwelling unit, 

including basements

(4) On every level of a residential board and 

care occupancy (small facility), including 

basements and excluding crawl spaces and 

unfinished attics

(5) In the living area(s) of a guest suite

(6) In the living area(s) of a residential board 

and care occupancy (small facility)

Are More Smoke Alarms Desirable? The 

required number of smoke detectors 

might not provide reliable early warning 

protection for those areas separated by 

a door from the areas protected by the 

required smoke detectors. For this reason, 

it is recommended that the householder 

consider the use of additional smoke 

detectors for those areas for increased 

protection. The additional areas include 

the basement, bedrooms, dining room, 

furnace room, utility room, and hallways not 

protected by the required smoke detectors. 

The installation of smoke detectors in 

kitchens, attics (finished or unfinished), or 

garages is not normally recommended, as 

these locations occasionally experience 

conditions that can result in improper 

operation.

The equipment should be installed using 

wiring methods in accordance with the 

National Fire Protection Association’s 

Standard 72, Chapter 11. (National Fire 

Protection Association, Batterymarch Park, 

Quincy, MA 02269).

IMPORTANT!

Specific requirements for Smoke Alarm 

installation vary from state to state and from 

region to region. Check with your local Fire 

Department for current requirements in 

your area.

SMOKE ALARMS

 (REx14 Series)

Sufficient smoke must enter your Smoke 

Alarm before it will respond. Your Smoke 

Alarm needs to be within 6.4 meters (21ft) 

of the fire to respond quickly. Smoke Alarms 

also need to be in positions where they can 

be heard throughout the property, so they 

can wake you and your family in time for 

everyone to escape. A single Smoke Alarm 

will give some protection if it is properly 

installed, but most homes will require two 

or more (preferably interconnected) to 

ensure that a reliable early warning is given. 

For recommended protection you should 

put individual Smoke Alarms in all rooms 

where fire is most likely to break out (apart 

from the kitchen and bathroom).

Your first Smoke Alarm should be located 

between the sleeping area and the most 

likely sources of fire (living room for 

example), but it should not be more than 

6.4 meters (21ft) from the door to any 

room where a fire may start and block your 

escape from the house.

Multi-Story Dwellings

If your home has more than one floor, at 

least one Alarm should be fitted on each 

level (see Figure 1). Preferably the Alarms 

should be interconnected (if feature is 

present on unit) so as to give sufficient 

warning throughout the property.

Figure 1 illustrates where Smoke and Heat 

Alarms should be located in a typical 

two story house. Note the spacings in 

“Protection Levels” which ensure the early 

detection of fire and that the warning will 

be heard.

Locate Heat Alarms in rooms adjoining 

escape routes - kitchens, garages, boiler 

houses etc. where Smoke Alarms are 

unsuitable.

Single Story Dwelling

If the premises is one story you should 

put your first Smoke Alarm in a corridor or 

hallway between the sleeping and living 

areas. Place it as near to the living area 

as possible, but make sure that it can be 

heard loudly enough in the bedroom to 

wake someone. See Figure 2 for placement 

example.

In houses with more than one sleeping area, 

Smoke Alarms should be placed between 

each sleeping area and the living area and 

it is recommended that Heat Alarms should 

be placed in the kitchen and garage.

Recommended Protection

Fire authorities recommend you put 

individual Smoke Alarms in or near all 

rooms where fire is most likely to break 

out (apart from the locations to avoid e.g 

bathrooms). The living room is the most 

likely place for a fire to start at night, 

followed by the kitchen (where a Heat Alarm 

is recommended) and then the dining room. 

Consideration should be given to installing 

Smoke Alarms in any bedrooms where fires 

might occur, for instance, where there is 

an electrical appliance such as an electric 

blanket or heater, or where the occupant is 

a smoker. In addition, consideration should 

be also given to installing Smoke Alarms in 

any rooms where the occupant is unable to 

respond very well to a fire starting in that 

room, such as an elderly or sick person or a 

very young child.

For placement of Heat and Smoke Alarms, 

see Figures 1 and 2. Locate Heat Alarms in 

rooms adjoining escape routes - kitchens, 

garages, boiler houses etc. where Smoke 

Alarms are unsuitable.

Figure 1

For minimum protection

- Smoke Alarm on each story

- in each sleeping area

- every 6.4 meters (21ft) of hallways and 

rooms

- within 3 meters (10ft) of all bedroom doors

- all units interconnected (where feature is 

present)

For recommended protection

(in addition to the above):

- Smoke Alarms in every room (except 

kitchens and bathrooms)

- Heat Alarms located in kitchens, 

garages etc. within 5.3m (17ft) of 

potential fire sources

3

Содержание RE617

Страница 1: ...st button until the Heat Alarm beeps 5 Remove the mounting plate and refer to Sections 2 and 5 for positioning and installation 6 After mounting plate is installed restore the Heat Alarm onto the mounting plate and fully test the Heat Alarm per Section 6 Alternate Enrollment Methods Scan the Heat Alarm s bar code using the Connect Installer app OR Enter the 8 character serial number on the interac...

Страница 2: ...ashes every 48 sec 3 Beeps Silence Sounding Alarm Press Release Button 1 Flash every 8 sec Off Off for 10 mins Silence End of Life indication up to 30 days Press Release Button Off Off for 72 hours Off for 72 hours Test Mode Action Red LED Yellow LED Sounder Test Heat Alarm Press Button Rapid Flashing Off Full Sound Alarm Memory Action Red Led Yellow LED Sounder 24 Hour Memory 2 Flashes every 48 s...

Страница 3: ...not be more than 6 4 meters 21ft from the door to any room where a fire may start and block your escape from the house Multi Story Dwellings If your home has more than one floor at least one Alarm should be fitted on each level see Figure 1 Preferably the Alarms should be interconnected if feature is present on unit so as to give sufficient warning throughout the property Figure 1 illustrates wher...

Страница 4: ...ng Alarms Can Be Heard With the Alarms sounding in their intended locations check that the alarm can be heard in each bedroom with the door closed above the sound of any TV audio systems The TV audio systems should be set to a reasonably loud conversation level If you cannot hear the alarm over the sound of the TV audio system the chances are it would not wake you This unit is required to be insta...

Страница 5: ...all screwdriver to release the catch push catch towards the ceiling and then twist off the Alarm see Figure 5b Figure 5a How to Tamperproof BREAK OFF SMALL PILLAR 3 Get out as fast as you can Do not stop for packing Have a prearranged meeting place outside for all family members Check everybody is there 4 Call the Fire Department from a neighbor s house or mobile phone Remember to give your name a...

Страница 6: ...conds with the yellow light flashing at the same time Replace the batteries 6 3 2 Battery Replacement When the batteries power is low and replacement is necessary the Heat Alarm will beep and the yellow light will flash at the same time about once every 48 seconds for at least 7 days The batteries must then be replaced Also replace the batteries if the Alarm does not sound when the Test Button is ...

Страница 7: ...y for further advice 7 Getting Your Alarm Serviced If your Alarm fails to work after you have read the sections on Installation and Testing Maintenance and Power Supply Monitoring contact Tech Support at the phone number provided at the end of this guide For product returns ensure the product is shipped with the batteries disconnected and return to Alula Attn RMA 2340 Energy Park Drive Suite 100 S...

Страница 8: ... FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference that may be received including interference that may cause undesired operation Changes or modifications not expressly approved by Alula could void the user s authority to operate this equipment FCC ID U5X RE314 IC NOTICE This device complies wi...

Отзывы: