background image

chimney, in a wall cavity, or if the prevailing 

air draughts carry the smoke or heat away.  

Installing Smoke Alarms on both sides of closed 

doors and installing more than one Alarm as 

recommended in this leaflet very significantly 

improve the probability of early detection.

• The Smoke Alarms may not be heard.

• A Smoke Alarm may not wake a person who 

has taken drugs or alcohol.

• The Alarms may not detect every type of 

fire to give sufficient early warning. They 

are particularly ineffective with: fires caused 

by smoking in bed, escaping gas, violent 

explosions, poor storage of flammable rags 

and/or liquids, (for example petrol, paint, 

spirits etc), overloaded electrical circuits, arson, 

children playing with matches.

• Current studies have shown smoke alarms 

may not awaken all sleeping individuals, and 

that it is the responsibility of individuals in the 

household that are capable of assisting others 

to provide assistance to those who may not 

be awakened by the alarm sound, or to those 

who may be incapable of safely evacuating the 

area unassisted

Limitations of Heat Alarms

There are various situations where a Heat 

Alarm may not be effective:

• Fires where the victim is intimate with a 

flaming initiated fire; for example, when a 

person’s clothes catch fire while cooking.

• Fires where the heat is prevented from 

reaching the Heat Alarm due to a closed door 

or other obstruction.

• Incendiary fires where the fire grows so 

rapidly that an occupant’s egress is blocked 

even with properly located Heat Alarms

5. Getting Your Alarm Serviced

If your Alarm fails to work after you have 

read the sections on “Installation”, “Testing, 

Maintenance and Power Supply Monitoring”, 

then contact Customer Assistance at the nearest 

address given at the end of this leaflet. If it needs 

to be returned for repair or replacement put it 

in a padded box with the battery disconnected. 

Send it to “Customer Assistance” at the nearest 

address given on the Alarm or in this leaflet. State 

the nature of the fault, where the Alarm was 

purchased and the date of purchase.

6. Installation

Installation Procedure
1. Select a location complying with the advice 

in Section 2.
2. Lift off the mounting plate from the Smoke 

Alarm.

3. Place the mounting plate on the ceiling 

exactly where you want to mount the Alarm. 

With a pencil, mark the location of the two 

screw holes.
4. Taking care to avoid any electrical wiring in the 

ceiling, drill holes using a 5.0mm drill bit through 

the centre of the marked locations. Push the 

plastic screw anchors provided into the drilled 

holes. Screw the mounting plate to the ceiling.
5. Insert the battery or batteries as per the 

Quick Start Guide, ensuring the orientation 

is correct. If the battery is already installed in 

your Alarm just pull the battery tab to power 

the Alarm.

Figure 5

ROTATE UNIT ANTI-CLOCKWISE

UNIT WILL NOT TWIST OFF - IT MAY BE

TAMPERPROOFED - SEE FIGURE 8

6. Carefully line up the Alarm on to the 

mounting plate, gentle press home and twist 

clockwise. 
Install all the other Alarms similarly.
7. Press the Test button on each Alarm to ensure 

that the Alarm works (see Figure 6).  

Figure 6

Smoke Alarm

Tamperproofing the Alarm

The Alarm can be made tamperproof to prevent 

unauthorised removal of the Alarm.
Break off the small pillar on the base as shown 

in  Figure 7a.  To remove the Alarm from 

the ceiling it is now necessary to use a small 

screwdriver, to release the catch (push catch 

towards the ceiling) and then twist off the 

7

Содержание RE314

Страница 1: ...nd then holding down the smoke s test button until the smoke alarm beeps 5 Remove the mounting plate and refer to Sections 2 and 6 for positioning and installation 6 After mounting plate is installed restore the smoke alarm onto the mounting plate and fully test the smoke alarm per Section 7 To replace the battery detach the smoke alarm from its mounting plate and replace the batteries Attention T...

Страница 2: ...under Low Battery Off 1 Flash every 48 sec 1Beep Faulty Smoke Sensor Off 2Flashesevery48sec 2 Beeps Faulty Heat Sensor Off 2Flashesevery48sec 2 Beeps End of Life Off 3Flashesevery48sec 3 Beeps Silence Sounding Alarm Press ReleaseButton 1 Flash every 8 sec Off Off for 10 mins Silence End of Life indication up to 30 days Press ReleaseButton Off Off for 72 hours Off for 72 hours Test Mode Action Red ...

Страница 3: ...ed smoke detectors Theinstallationofsmokedetectorsinkitchens attics finished or unfinished or garages is notnormallyrecommended astheselocations occasionally experience conditions that can result in improper operation The equipment should be wired and installed in accordance with National Fire Protection Association s Standard 72 Chapter 11 and National Electric Code NFPA 70 Chapter 3 National Fir...

Страница 4: ...CORNER SMOKE ALARMS 610mm 24 FROM APEX DEAD AIR SPACE Wall Mounting Ifceilingmountingisimpractical SmokeAlarms may be mounted on a wall provided that a the top of the detection element is between 150mm 6 and305mm 12 belowtheceiling see Figure 3a b the bottom of the detection element is above the level of any door openings Wallmountingshouldonlybeconsideredwhere closespacedbeamsorsimilarobstruction...

Страница 5: ...kly silenced by fanningvigorouslywithanewspaperorsimilar to remove the smoke or press the test hush button Do not attempt to recharge or burn the battery as it may explode If it is necessary to remove the battery for separate disposal handle carefully to avoid possible eye damage or skin irritation if battery has leaked or corroded To maintain sensitivity to smoke do not paint or cover the Alarm i...

Страница 6: ...bstituteforinsurance The supplier or manufacturer is not your insurer Fire Safety Hints Store petrol and other flammable materials in proper containers Discard oily or flammable rags Always use a metal fireplace screen and have chimneys cleaned regularly Replace worn or damaged sockets switches home wiring and cracked or frayed electrical cords and plugs Do not overload electrical circuits Keep ma...

Страница 7: ...stallation Testing Maintenance and Power Supply Monitoring thencontactCustomerAssistanceatthenearest addressgivenattheendofthisleaflet Ifitneeds to be returned for repair or replacement put it in a padded box with the battery disconnected Send it to Customer Assistance at the nearest addressgivenontheAlarmorinthisleaflet State the nature of the fault where the Alarm was purchased and the date of p...

Страница 8: ... Alarms in the system WARNING Do not test with flame This can set fire to the Alarm and damage the house We do not recommend testing with smoke as the results can be misleading unless special apparatus is used When you press the Test button it simulates the effect of smoke in a Smoke Alarm which it could experience in a real fire 7 2 Test Silence Button to Control Nuisance Alarms The Smoke Alarms ...

Страница 9: ...8 seconds to indicate that the unit has been silenced 2 The Smoke Alarm will reset to normal sensitivity at the end of the silenced period 10 minutes If additional silenced time is required simply push the Test Silence button again 3 If kitchen usage layout is such that there are an unacceptable level of nuisance alarms re locatetheSmokeAlarmfurtherawaywhere it will be less affected by cooking fum...

Страница 10: ...ld up Any insects or cobwebs in the vicinity of the Smoke Alarm should be promptly removed In certain circumstances even with regular cleaning contamination can build up in the smoke sensing chamber causing the Alarm to sound If this happens the Smoke Alarm mustbereturnedforservicingorreplacement Contamination is beyond our control it is totallyunpredictableandisconsiderednormal wear and tear For ...

Страница 11: ... the Test button is pressed Check the age of the unit see the replace by label on side of unit If necessary replace the battery or batteries with Panasonic CR123A 9 System Compatibility and Wireless Verification Smoke alarm model RE314 has only been evaluated at ETL with DSC Impassa Model SCW9057 and Power Series Control Panel Model PC1832 Test the system after finishing installation enrollment an...

Страница 12: ...ot cause interference and 2 This device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux cnr d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 L appareil ne doit pas produire de brouillage et 2 L utilisateur de l appareil doit acc...

Отзывы: