background image

Pro Tip

Pressing the test button

 on the smoke alarm will beep both the panel 

and smoke alarm.

Specifications

Physical 

Housing Dimensions
Weight with Batteries
Mounting Fastener

4.7 x 1.8 inches (12.0 x 4.6 centimeters)
7.36 ounces (210 grams)
#6 screws and anchors (provided)

Environmental

Operating Temperature
Maximum Humidity

40°F to 100°F  (4.4°C to 37.8°C), Long Term
15% to 95% non-condensing relative humidity

Sensor Specifications

Frequency
Replacement Batteries
Transmitted Indications
Loudness
Smoke Sensitivity
Heat Sensor

433.92 MHz
Two Panasonic CR123A   
Low Battery, Supervision
85 dBA at 10 feet (3m) minimum
1.95% to 4% OBS/Foot
135 ± 5°F (57 ± 2°C)

Certification

RE314

FCC, IC, UL217, ULC531

Specifications subject to change without notice.

47-0023-03 • RevB • 2018-03-19

 Tech Support Line • (888) 88-ALULA • (888) 882-5852

alula.net

WARRANTY

Alula will replace non-portable products that are 

defective in their first five (5) years and all defective 

portable products in their first two (2) years.

IC NOTICE

This device complies with Industry Canada license-

exempt RSS standard(s). Operation is subject to the 

following two conditions:
(1) This device may not cause interference, and

(2) This device must accept any interference, including 

interference that may cause undesired operation of 

the device.

Le présent appareil est conforme aux cnr d’Industrie 

Canada applicables aux appareils radio exempts de 

licence. L’exploitation est autorisée aux deux conditions 

suivantes:
(1) L’appareil ne doit pas produire de brouillage, et

(2) L’utilisateur de l’appareil doit accepter tout 

brouillage radioélectrique subi, même si le 

brouillage est susceptible d’en compromettre le 

fonctionnement.

IC: 8310A-RE314

FCC NOTICE

This device complies with Part 15 of the FCC rules. 

Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.

(2) This device must accept any interference that may 

be received, including interference that may cause 

undesired operation.

Changes or modifications not expressly approved by 

Alula could void the user’s authority to operate this 

equipment.
FCC ID: U5X-RE314

TRADEMARKS

Alula is a trademark owned by Alula Holdings, LLC.
DSC is a trademark owned by TYCO Safety Products 

Canada LTD. 
Alula products will function with DSC systems. However, 

no Alula product is produced by, endorsed by, nor 

is officially associated with DSC. Alula recommends 

verifying proper enrollment and operation, per control 

panel installation instructions, at installation.

Содержание RE314

Страница 1: ...nd then holding down the smoke s test button until the smoke alarm beeps 5 Remove the mounting plate and refer to Sections 2 and 6 for positioning and installation 6 After mounting plate is installed restore the smoke alarm onto the mounting plate and fully test the smoke alarm per Section 7 To replace the battery detach the smoke alarm from its mounting plate and replace the batteries Attention T...

Страница 2: ...under Low Battery Off 1 Flash every 48 sec 1Beep Faulty Smoke Sensor Off 2Flashesevery48sec 2 Beeps Faulty Heat Sensor Off 2Flashesevery48sec 2 Beeps End of Life Off 3Flashesevery48sec 3 Beeps Silence Sounding Alarm Press ReleaseButton 1 Flash every 8 sec Off Off for 10 mins Silence End of Life indication up to 30 days Press ReleaseButton Off Off for 72 hours Off for 72 hours Test Mode Action Red ...

Страница 3: ...ed smoke detectors Theinstallationofsmokedetectorsinkitchens attics finished or unfinished or garages is notnormallyrecommended astheselocations occasionally experience conditions that can result in improper operation The equipment should be wired and installed in accordance with National Fire Protection Association s Standard 72 Chapter 11 and National Electric Code NFPA 70 Chapter 3 National Fir...

Страница 4: ...CORNER SMOKE ALARMS 610mm 24 FROM APEX DEAD AIR SPACE Wall Mounting Ifceilingmountingisimpractical SmokeAlarms may be mounted on a wall provided that a the top of the detection element is between 150mm 6 and305mm 12 belowtheceiling see Figure 3a b the bottom of the detection element is above the level of any door openings Wallmountingshouldonlybeconsideredwhere closespacedbeamsorsimilarobstruction...

Страница 5: ...kly silenced by fanningvigorouslywithanewspaperorsimilar to remove the smoke or press the test hush button Do not attempt to recharge or burn the battery as it may explode If it is necessary to remove the battery for separate disposal handle carefully to avoid possible eye damage or skin irritation if battery has leaked or corroded To maintain sensitivity to smoke do not paint or cover the Alarm i...

Страница 6: ...bstituteforinsurance The supplier or manufacturer is not your insurer Fire Safety Hints Store petrol and other flammable materials in proper containers Discard oily or flammable rags Always use a metal fireplace screen and have chimneys cleaned regularly Replace worn or damaged sockets switches home wiring and cracked or frayed electrical cords and plugs Do not overload electrical circuits Keep ma...

Страница 7: ...stallation Testing Maintenance and Power Supply Monitoring thencontactCustomerAssistanceatthenearest addressgivenattheendofthisleaflet Ifitneeds to be returned for repair or replacement put it in a padded box with the battery disconnected Send it to Customer Assistance at the nearest addressgivenontheAlarmorinthisleaflet State the nature of the fault where the Alarm was purchased and the date of p...

Страница 8: ... Alarms in the system WARNING Do not test with flame This can set fire to the Alarm and damage the house We do not recommend testing with smoke as the results can be misleading unless special apparatus is used When you press the Test button it simulates the effect of smoke in a Smoke Alarm which it could experience in a real fire 7 2 Test Silence Button to Control Nuisance Alarms The Smoke Alarms ...

Страница 9: ...8 seconds to indicate that the unit has been silenced 2 The Smoke Alarm will reset to normal sensitivity at the end of the silenced period 10 minutes If additional silenced time is required simply push the Test Silence button again 3 If kitchen usage layout is such that there are an unacceptable level of nuisance alarms re locatetheSmokeAlarmfurtherawaywhere it will be less affected by cooking fum...

Страница 10: ...ld up Any insects or cobwebs in the vicinity of the Smoke Alarm should be promptly removed In certain circumstances even with regular cleaning contamination can build up in the smoke sensing chamber causing the Alarm to sound If this happens the Smoke Alarm mustbereturnedforservicingorreplacement Contamination is beyond our control it is totallyunpredictableandisconsiderednormal wear and tear For ...

Страница 11: ... the Test button is pressed Check the age of the unit see the replace by label on side of unit If necessary replace the battery or batteries with Panasonic CR123A 9 System Compatibility and Wireless Verification Smoke alarm model RE314 has only been evaluated at ETL with DSC Impassa Model SCW9057 and Power Series Control Panel Model PC1832 Test the system after finishing installation enrollment an...

Страница 12: ...ot cause interference and 2 This device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux cnr d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 L appareil ne doit pas produire de brouillage et 2 L utilisateur de l appareil doit acc...

Отзывы: