WayPoint307A
- 3 -
Overview:
Altronix WayPoint307A Outdoor Power Supply provides 24VAC or 28VAC distributed via two outputs for
powering CCTV cameras, heaters, and other video accessories .
Specifications:
Installation Instructions:
Unit should be installed in accordance with The National Electrical Code and all applicable Local Regulations .
1 . Remove back plane from enclosure prior to mounting (do not discard hardware) .
2 . Mark and drill desired inlets on the enclosure to facilitate wiring (Fig. 2, pg. 5).
3 . Mount unit in desired location . Mount unit in the desired location . For wall mounting refer to Fig. 3, pg. 7 .
For pole mounting installation refer to pg. 7 - Pole Mounting Using Optional Pole Mount Kit PMK1 .
4 . Mount back plane to enclosure with hardware .
5 . To facilitate wire entry, utilize weather-tight NEMA 4 rated connectors, bushings and cable .
6 . Connect unswitched AC power (277VAC/60 Hz) to terminals marked [L, G, N] (Fig. 1, pg. 4) .
Wire gauge range of connectors is 14 AWG to 11 AWG (1 .6 mm to 2 .5 mm diameter) .
7 . LEDs will illuminate indicating each output is powered (Fig. 1, pg. 4) .
8 . Measure output voltage on terminals marked [COM, 24V, 28V] before connecting devices (Fig. 1, pg. 4) .
This helps avoiding potential damage .
9 . For 24VAC output connect devices to terminals marked [COM, 24V] (Fig. 1, pg. 4) .
For 28VAC output connect devices to terminals marked [COM, 28V] (Fig. 1, pg. 4) .
10 . Upon completion of wiring, secure enclosure door with latches and optional lock .
Caution: Equipment to be installed / serviced by authorized / trained personnel only .
Shut branch circuit power before installing / servicing equipment .
WARNING: When installing in a non-restricted service area use lock or other fastened means on door
latches. This installation should be made by qualified service personnel and should conform to the
National Electrical Code and all local codes.
Terminal and LED Identification Chart:
Output
Terminals
LED
LED Status
ON
OFF
COM and 24V
24VAC
Normal operating condition .
No AC output .
Blown fuse, AC failure .
COM and 28V
28VAC
Agency Listing:
• CE European Conformity .
Input:
• Input: 277VAC, 60Hz, 1 .75A .
Output:
• Output options:
a . 24VAC @ 12 .5A max .
b . 28VAC @ 10A max .
c . Both 24VAC and 28VAC not to exceed 10A max .
• Output fuses rated @ 15A/32V .
Features:
• Individual power output LED indicators .
• Spare fuses included .
Enclosure:
• NEMA 4/4X, IP66-11 Rated enclosure for
outdoor use .
• Integral flanges simplify wall or pole mounting .
• Enclosure Dimensions (H x W x D approx .):
13 .31” x 11 .31” x 5 .59”
(338 .1 mm x 287 .3 mm x 142 mm) .