background image

 

WayPoint307A 

- 3 -

Overview:

Altronix WayPoint307A Outdoor Power Supply provides 24VAC or 28VAC distributed via two outputs for 
powering CCTV cameras, heaters, and other video accessories .

Specifications:

Installation Instructions:

Unit should be installed in accordance with The National Electrical Code and all applicable Local Regulations .
1 .  Remove back plane from enclosure prior to mounting (do not discard hardware) .
2 .  Mark and drill desired inlets on the enclosure to facilitate wiring (Fig. 2, pg. 5).
3 .  Mount unit in desired location . Mount unit in the desired location . For wall mounting refer to Fig. 3, pg. 7 .
 

For pole mounting installation refer to pg. 7 - Pole Mounting Using Optional Pole Mount Kit PMK1 .

4 .  Mount back plane to enclosure with hardware .
5 .  To facilitate wire entry, utilize weather-tight NEMA 4 rated connectors, bushings and cable .
6 .  Connect unswitched AC power (277VAC/60 Hz) to terminals marked [L, G, N] (Fig. 1, pg. 4) . 
 

Wire gauge range of connectors is 14 AWG to 11 AWG (1 .6 mm to 2 .5 mm diameter) .

7 .  LEDs will illuminate indicating each output is powered (Fig. 1, pg. 4) .
8 .  Measure output voltage on terminals marked [COM, 24V, 28V] before connecting devices (Fig. 1, pg. 4) .
 

This helps avoiding potential damage .

9 .  For 24VAC output connect devices to terminals marked [COM, 24V] (Fig. 1, pg. 4) .
 

For 28VAC output connect devices to terminals marked [COM, 28V] (Fig. 1, pg. 4) .

10 .  Upon completion of wiring, secure enclosure door with latches and optional lock .
 

Caution: Equipment to be installed / serviced by authorized / trained personnel only . 

 

Shut branch circuit power before installing / servicing equipment .

WARNING: When installing in a non-restricted service area use lock or other fastened means on door 
latches. This installation should be made by qualified service personnel and should conform to the 
National Electrical Code and all local codes.

Terminal and LED Identification Chart:

Output
Terminals

LED

LED Status

ON

OFF

COM and 24V

24VAC

Normal operating condition .

No AC output . 
Blown fuse, AC failure .

COM and 28V

28VAC

Agency Listing:

•  CE European Conformity .

Input:

•  Input: 277VAC, 60Hz, 1 .75A .

Output:

•  Output options:
  a .  24VAC @ 12 .5A max .
  b .  28VAC @ 10A max .
  c .  Both 24VAC and 28VAC not to exceed 10A max .
•  Output fuses rated @ 15A/32V .

Features:

•  Individual power output LED indicators .
•  Spare fuses included .

Enclosure:

•  NEMA 4/4X, IP66-11 Rated enclosure for
  outdoor use .
•  Integral flanges simplify wall or pole mounting .
•  Enclosure Dimensions (H x W x D approx .):
  13 .31” x 11 .31” x 5 .59”
  (338 .1 mm x 287 .3 mm x 142 mm) .

Содержание WayPoint307A

Страница 1: ...Rev 080911 More than just power TM WayPoint307A AC Outdoor Power Supply Installation Guide ...

Страница 2: ...3 Specifications pg 3 Installation Instructions pg 3 Terminal and LED Identification Chart pg 3 Suggested Locations for Wiring Inlets pg 5 Wall Mount Installation pg 7 Pole Mounting Using Optional Pole Mount Kit PMK1 pg 7 Enclosure Dimensions pg 8 ...

Страница 3: ...e connecting devices Fig 1 pg 4 This helps avoiding potential damage 9 For 24VAC output connect devices to terminals marked COM 24V Fig 1 pg 4 For 28VAC output connect devices to terminals marked COM 28V Fig 1 pg 4 10 Upon completion of wiring secure enclosure door with latches and optional lock Caution Equipment to be installed serviced by authorized trained personnel only Shut branch circuit pow...

Страница 4: ...d DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance CAUTION To reduce the risk of electric shock do not open enclosure There ar...

Страница 5: ...WayPoint307A 5 Bottom of Enclosure Suggested Locations for Wiring Inlets Fig 2 ...

Страница 6: ... 6 WayPoint307A Notes ...

Страница 7: ...trap through the locking mechanism on the strap then tighten the screw with flat head screwdriver or 5 16 hex socket driver Fig 5 pg 7 and Fig 7 pg 7 3 Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket tightening bolts with a 7 16 hex socket Fig 6 pg 7 4 Thread the second wormgear quick release strap through the slots on the back...

Страница 8: ...ER Enclosure Dimensions H x W x D approx 13 31 x 11 31 x 5 59 338 1mm x 287 3mm x 142mm 1 61 40 9mm 3 96 100 6mm 5 59 142mm 10 32 X 0 375 9 6mm BRASS INSERT X4 STAINLESS STEEL PIANO HINGE 11 31 287 3mm 13 31 338 1mm PADLOCK LATCH ATTACHED WITH RIVETS Ø 0 375 9 5mm PADLOCK EYE 10 75 273 1mm 10 00 254mm 8 25 209 6mm 10 25 260 4mm 12 00 304 8mm 13 50 342 9mm 10 32 X 0 25 6 4mm BRASS INSERT X2 Ø 0 32 ...

Отзывы: