background image

- 2 -

Vertiline8

Overview:

Altronix Vertiline CCTV Rack Mount Power Supplies provide 8 power outputs in a space saving 1U EIA 19” rack mount
chassis which may be rack, wall or shelf mounted. The units feature individually selectable 24VAC and/or 28VAC power
outputs with surge suppression. Vertiline CCTV Rack Mount Power Supplies are also available in sixteen (16) and twenty-
four (24) output models with various power ratings. 

Specifications:

Eight (8) Output Rack Mount Configuration Reference Chart:

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or 
moisture. This installation should be made by qualified service personnel and should conform to
all local codes and in accordance with the National Electrical Code.

Installation Instructions:

1. Set the input voltage selector switch located on the left side of the Vertiline unit (facing front panel) for

115VAC or 230VAC operation 

(Fig. 1c, pg. 4)

.

2. Attach mounting brackets to Vertiline unit for rack or wall mount installation 

(Figs. 4-5, pg. 7)

. Affix rubber pads to 

Vertiline for shelf installation 

(Fig. 6, pg. 7)

.

3. Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least

3” from any video monitors). When installing the unit in a rack allow for one half of a U spacing above the unit
for ventilation.

4. Plug the grounded AC line cord (included) into the IEC 320 connector of the Vertiline unit 

(Fig. 1f, pg. 4)

Insert the plug end of the line cord into a grounded AC receptacle.

5. Set illuminated master power disconnect circuit breaker to the (ON) position 

(Fig. 3, pg. 6)

.

6. Select 24VAC or 28VAC power output for cameras 1-8 with the corresponding voltage adjustment switches

(Fig. 1b, pg. 4)

.

7. Measure output voltage before connecting cameras. This helps avoid potential damage.

All terminals with common suffix (P) “1P, 2P ...” are the same polarity.

8. Set illuminated master power disconnect circuit breaker to the (OFF) position 

(Fig. 3, pg. 6)

• Selectable 115VAC 60 Hz/230VAC 50/60 Hz input.
• Eight (8) individually selectable 24VAC or 28VAC

power outputs with OFF position.

• Eight (8) power LED indicators.
• External blade fuses or PTC protected outputs.
• Surge suppression.
• Illuminated power disconnect circuit breaker with

manual reset.

• IEC 320 - 3-wire grounded line cord (detachable).
• Removable terminal blocks with locking screw flange.
• Ease of installation saves time and eliminates costly labor.
• Compact 1U rack mount chassis.
• Fits standard EIA 19” rack.
• Units can be rack, wall or shelf mounted.

Altronix 
Model
Number

Vertiline8

24VAC or

28VAC

5 amp

8 Fused

--

3 amp 3 amp

10 amp 1.5 amp .8 amp

UL Listed for

Commercial 

CCTV Equipment

(UL 2044). 

Vertiline8D

24VAC or 

28VAC

5 amp

8

--

PTC 2.5 amp

--

Vertiline83

24VAC or 

28VAC

10 amp 8 Fused

--

3 amp 3 amp

15 amp 3 amp 1.5 amp

Vertiline83D

24VAC or 

28VAC

10 amp 8

--

PTC 2.5 amp

--

Total

 Output Cur

rent (P

ow

er)

OutputV

oltage (V

A

C)

Number of Outputs

Output Protection

Class 2 Rated P

ow

er Limited 

Output Protection

Cur

rent 

(max. per output)

115V

A

C 60Hz

Input Cur

rent

230V

A

C 50/60Hz

Input Cur

rent

Agenc

y Listings

Fuse RatingMain Fuse Rating

Содержание Vertiline8

Страница 1: ...ertiline8D 24VAC or 28VAC 5 amp 24VAC or 28VAC 5 amp Eight 8 fuse protected outputs Eight 8 PTC protected outputs Vertiline83 Vertiline83D 24VAC or 28VAC 10 amp 24VAC or 28VAC 10 amp Eight 8 fuse protected outputs Eight 8 PTC protected outputs Rev 031808 More than just power TM ...

Страница 2: ...ated master power disconnect circuit breaker to the ON position Fig 3 pg 6 6 Select 24VAC or 28VAC power output for cameras 1 8 with the corresponding voltage adjustment switches Fig 1b pg 4 7 Measure output voltage before connecting cameras This helps avoid potential damage All terminals with common suffix P 1P 2P are the same polarity 8 Set illuminated master power disconnect circuit breaker to ...

Страница 3: ...Vertiline unit or the illuminated master power disconnect circuit breaker is in the OFF position or the main fuse 1 8 is blown Fig 1d pg 4 To restore the power output for Vertiline8 or Vertiline83 1 Switch corresponding output voltage switch to the OFF position Fig 1b pg 4 2 Eliminate the trouble condition 3 Replace the corresponding automotive blade fuse 4 Switch output voltage switch to the 24VA...

Страница 4: ...cators 1g IEC 320 Connector 115VAC 60Hz 230VAC 50 60Hz grounded line cord included Fig 1 1c Input Voltage Switch Selects 115VAC 230VAC 50 60Hz switch is located on the left side of the unit 115VAC 220VAC 1e Power Outputs 24VAC or 28VAC 1f Output Fuses Automotive blade fuses Vertiline8 Vertiline8D Vertiline83 or Vertiline83D front Vertiline8 or Vertiline83 rear Vertiline8D or Vertiline83D rear Vert...

Страница 5: ...Vertiline8 5 Fig 2 AC POWER Main Fuse 1 8 1 2 3 4 5 6 7 8 N P N P N P N P N P N P N P N P 1 2 3 4 5 6 7 8 28VAC OFF 24VAC OFF RESET Typical Hookup ...

Страница 6: ...d Outputs not powered To reset circuit breaker set power switch to the ON RESET position Fig 3 pg 6 The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the products enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral tria...

Страница 7: ... of rack chassis Fig 4a 2 Install mounting brackets A on the left and right side of rack chassis using the two 2 flat head screws B included Fig 4b 3 Place unit into desired EIA 19 rack position and secure with mounting screws not included Fig 4c Fig 6 Fig 5 Shelf Installation 1 Position and affix rubber pads C included at each corner on the bottom of the unit Fig 6 2 Place unit in desired locatio...

Страница 8: ...esponsible for any typographical errors Altronix Corp 140 58th Street Brooklyn New York 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIVertiline8Series J10H Notes ...