CCTV Rack Mount Power Supplies

Installation Guide

Models Include:

Vertiline16 Vertiline16D

  - 24VAC or 28VAC @ 10A 

  - 24VAC or 28VAC @ 10A

  - Sixteen (16) fuse protected outputs 

  - Sixteen (16) PTC protected outputs

Vertiline166 Vertiline166D

  - 24VAC or 28VAC @ 14A 

  - 24VAC or 28VAC @ 14A

  - Sixteen (16) fuse protected outputs 

  - Sixteen (16) PTC protected outputs

More than just power.

TM

Rev. 031808

Содержание Vertiline16

Страница 1: ...tiline16D 24VAC or 28VAC 10A 24VAC or 28VAC 10A Sixteen 16 fuse protected outputs Sixteen 16 PTC protected outputs Vertiline166 Vertiline166D 24VAC or 28VAC 14A 24VAC or 28VAC 14A Sixteen 16 fuse protected outputs Sixteen 16 PTC protected outputs More than just power TM Rev 031808 ...

Страница 2: ...ode and all local codes Installation Instructions 1 Set the input voltage selector switch located on the left side of the Vertiline unit facing front panel for 115VAC or 230VAC operation Fig 1c pg 4 2 Attach mounting brackets to Vertiline unit for rack or wall mount installation Figs 4 5 pg 7 Affix rubber pads to Vertiline for shelf installation Fig 6 pg 7 3 Secure the unit in a rack mount unit to...

Страница 3: ...tput may be due to a blown fuse or a tripped PTC caused by a short circuit or overload condition If all of the LEDs are OFF there may be a complete loss of supply power to the Vertiline unit or the illuminated master power disconnect circuit breaker is in the OFF position or the main fuse 1 8 or 9 16 is blown Fig 1d pg 4 To restore the power output for Vertiline16 or Vertiline166 1 Switch correspo...

Страница 4: ...t 1d Main Fuse Protects the transformer against overload 1a LED s 1 16 Power LED indicators Fig 1 1c Input Voltage Switch Selects 115VAC 230VAC 50 60Hz switch is located on the left side of the unit 115VAC 220VAC 1e Power Outputs 24VAC or 28VAC 1f Output Fuses Automotive blade fuses Vertiline16 Vertiline16D Vertiline166 or Vertiline166D front Vertiline16 or Vertiline166 rear Vertiline16D or Vertil...

Страница 5: ...FF 24VAC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 28VAC OFF 24VAC OFF RESET AC POWER 13 14 15 16 N P N P N P N P 9 10 11 12 N P N P N P N P Main Fuse 9 16 5 6 7 8 N P N P N P N P 1 2 3 4 N P N P N P N P Main Fuse 1 8 Typical Hookup ...

Страница 6: ...wered Circuit breaker tripped Switch not illuminated Power LEDs on faceplate are not illuminated Outputs not powered To reset circuit breaker set power switch to the ON RESET position Fig 3 pg 6 The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of suffi...

Страница 7: ...s of rack chassis Fig 4a 2 Install mounting brackets A on the left and right side of rack chassis using the two 2 flat head screws B included Fig 4b 3 Place unit into desired EIA 19 rack position and secure with mounting screws not included Fig 4c Fig 6 Fig 5 Shelf Installation 1 Position and affix rubber pads C included at each corner on the bottom of the unit Fig 6 2 Place unit in desired locati...

Страница 8: ...esponsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIVertiline16Series F10P Notes MEMBER ...

Отзывы: