Configuration of Altronix Power Supply and/or Sub-Assemblies and 

Suprema CoreStation module:

1.  Fasten metal and snap on spacers (provided) to pems which match the hole pattern for Altronix Power Supply/Chargers or Altronix 

 

Sub-Assembly boards 

(Fig. 2, 2a, pg. 3)

. Note: Please fasten metal and snap on spacers in the proper locations 

(Fig. 2, pg. 3)

.

2.  Mount boards to spacers utilizing 5/16” pan head screws (provided) 

(Fig. 2, pg. 3

).

3.  Mount module to spacers utilizing 5/16” pan head screws (provided) 

(Fig. 2, 2a, pg. 3)

.

 

Note:  Suprema CoreStation modules have one (1) RJ45 jack each. Please make sure that it is mounted correctly, as shown in 

Fig. 2

 below. 

4.  Fasten backplane to Trove1 enclosure utilizing pan head screws (provided).

Fig. 2

Altronix

Power Supply

Metal Spacer Placement

Altronix

Sub-Assembly

Altronix

Sub-Assembly

5

Suprema

CoreStation

RJ45

Pem

Spacer

Suprema CoreStation

module

Backplane

Pan Head

Screw

Fig. 2a

Содержание TROVE Trove1SP1

Страница 1: ...lling Company __________________________ Service Rep Name ___________________________________________ Address __________________________________________________________ Phone __________________________ All registered trademarks are property of their respective owners More than just power Installation Guide Access Power Integration ...

Страница 2: ...umérique de la classe B est conforme á la norme NMB 003 du Canada CE European Conformity Installation Instructions for Trove1 1 Remove backplane from enclosure prior to mounting do not discard hardware 2 Mark and predrill holes on the wall to line up with the top two keyholes in the enclosure Install two upper fasteners and screws in the wall with the screw heads protruding Place the enclosure s u...

Страница 3: ...ig 2 pg 3 2 Mount boards to spacers utilizing 5 16 pan head screws provided Fig 2 pg 3 3 Mount module to spacers utilizing 5 16 pan head screws provided Fig 2 2a pg 3 Note Suprema CoreStation modules have one 1 RJ45 jack each Please make sure that it is mounted correctly as shown in Fig 2 below 4 Fasten backplane to Trove1 enclosure utilizing pan head screws provided Fig 2 Altronix Power Supply Me...

Страница 4: ...0 6 15 2mm 14 5 321 3mm 1 45 36 8mm 7 25 184 2mm 1 95 49 5mm 1 1 27 9mm 0 6 15 2mm 0 57 14 5mm 18 0 457 2mm 1 25 31 8mm Trove1SP1 Enclosure Dimensions H x W x D 18 x 14 5 x 4 625 457mm x 368mm x 118mm Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com IITrove1SP1...

Отзывы: