Overview:

Altronix Trove1SP1 accommodates one (1) Suprema CoreStation module with or without Altronix power supply and sub-assemblies.

Specifications:

• 16 Gauge backplane and enclosure with ample knockouts for convenient access.

Trove1SP1

Trove1 enclosure with TSP1 Altronix/Suprema backplane

• Includes: tamper switch, cam lock, lock nuts, and mounting hardware.

  Enclosure Dimensions (H x W x D): 18” x 14.5” x 4.625” (457mm x 368mm x 118mm).

TSP1

Altronix/Suprema backplane only 

• Includes mounting hardware.

  Dimensions (H x W x D): 16.625” x 12.5” x 0.3125” (422.3mm x 317.5mm x 7.9mm).

TSP1 accommodates a combination of the following:

 Altronix Modules:

    One (1) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2, eFlow4NB, eFlow6NB, eFlow102NB or eFlow104NB.

    Two (2) ACM4, ACM4CB, AL175ULB, LINQ8PD, LINQ8PDCB, MOM5, PD4UL, PD4ULCB, PD8UL, PD8ULCB, PDS8, PDS8CB 

 Suprema:

  One (1) Suprema CoreStation module.

Agency Listings:

• UL 294 - 6th edition: Line Security I, Destructive Attack I, Endurance IV, Stand-by Power II*.

  *Stand-by Power Level I if no battery is supplied.

• This Class B digital apparatus complies with Canadian ICES-003. 

  Cet appareil numérique de la classe B est conforme á la norme NMB-003 du Canada.

• CE European Conformity. 

Installation Instructions for Trove1:

1.  Remove backplane from enclosure prior to mounting (do not discard hardware).

2.  Mark and predrill holes on the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in 

 

the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws; level and secure. 

 

Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the enclosure’s 

 

upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws.

3.  Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. 

 

Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side 

(Fig. 1, pg. 1)

 

Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. 

 

To activate alarm signal open the door of the enclosure.

4.  Mount Altronix/Suprema modules to TSP1 backplane, refer to

 page 3.

Hardware:

Fig. 1

Tamper Switch

(included)

To Access Control Panel or

UL Listed Reporting Device

Edge of

Enclosure

Enclosure

Nylon Spacer |            5/16” Pan Head Screw |         Lock Nut

Содержание TROVE Trove1SP1

Страница 1: ...lling Company __________________________ Service Rep Name ___________________________________________ Address __________________________________________________________ Phone __________________________ All registered trademarks are property of their respective owners More than just power Installation Guide Access Power Integration ...

Страница 2: ...umérique de la classe B est conforme á la norme NMB 003 du Canada CE European Conformity Installation Instructions for Trove1 1 Remove backplane from enclosure prior to mounting do not discard hardware 2 Mark and predrill holes on the wall to line up with the top two keyholes in the enclosure Install two upper fasteners and screws in the wall with the screw heads protruding Place the enclosure s u...

Страница 3: ...ig 2 pg 3 2 Mount boards to spacers utilizing 5 16 pan head screws provided Fig 2 pg 3 3 Mount module to spacers utilizing 5 16 pan head screws provided Fig 2 2a pg 3 Note Suprema CoreStation modules have one 1 RJ45 jack each Please make sure that it is mounted correctly as shown in Fig 2 below 4 Fasten backplane to Trove1 enclosure utilizing pan head screws provided Fig 2 Altronix Power Supply Me...

Страница 4: ...0 6 15 2mm 14 5 321 3mm 1 45 36 8mm 7 25 184 2mm 1 95 49 5mm 1 1 27 9mm 0 6 15 2mm 0 57 14 5mm 18 0 457 2mm 1 25 31 8mm Trove1SP1 Enclosure Dimensions H x W x D 18 x 14 5 x 4 625 457mm x 368mm x 118mm Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com IITrove1SP1...

Отзывы: