background image

 

- 6 -  

TroveHW

Installation Instructions for Honeywell PRO32E1PS or PW6K2E2PS to THW3:

1.  Install four (4) mounting screws approximately halfway into mounting holes in the power supply’s frame.
2.  Position the power supply over four (4) keyholes (B) on THW3 so the AC Input terminal marked [CN1] (smaller opening in the frame) 
 

is positioned to the bottom.

3.  Slide the power supply to the left until secure. Tighten the mounting screws.

Installation Instructions for Honeywell Access Controllers to THW3:

1.  Fasten standoffs (provided) into pem configuration (A) or (C) of backplane (Fig. 5, pg. 6).
2.  Mount boards to standoffs utilizing 5/16” pan head screws (provided) (Fig. 5a, pg. 6).
3.  Mount backplane to enclosure with hardware.

Honeywell ProWatch/WinPak Power Supply or Access Controller 

Position Chart for the Following Models:

Honeywell Board

Pem Mounting

3200 Series or WIN-PAK Series

A

PRO32E1PS or PW6K2E2PS

B

PRO22MX8

C

Pem

Standoff

Honeywell

Access Controller

Backplane

Pan Head

Screw

Fig. 5a

A

A

A

A

A

A

A

A

A

B

B

C

C

Fig. 5

Содержание TROVE THW2

Страница 1: ...WinPak backplane THW3 THW3 Altronix Honeywell ProWatch WinPak backplane only Installation Guide All registered trademarks are property of their respective owners More than just power Installing Compa...

Страница 2: ...knockouts for convenient access Enclosure Dimensions H x W x D 27 25 x 21 75 x 6 5 692 2mm x 552 5mm x 165 1mm Accommodates up to four 4 12VDC 7AH batteries THW2 THW2 Altronix Honeywell backplane 16...

Страница 3: ...ws provided Fig 2a pg 2 3 Mount backplane to enclosure with hardware Access Controller Position Chart for the Following Models Altronix Board Pem Mounting Altronix Power Supply Charger or Sub Assembly...

Страница 4: ...mounting screws Installation Instructions for Honeywell Access Controllers to THW2 1 Fasten standoffs provided into pem configuration A or C of backplane Fig 3 pg 4 2 Mount boards to standoffs utiliz...

Страница 5: ...provided Fig 4a pg 5 3 Mount backplane to enclosure with hardware Access Controller Position Chart for the Following Models Altronix Board Pem Mounting Altronix Power Supply Charger or Sub Assembly A...

Страница 6: ...the mounting screws Installation Instructions for Honeywell Access Controllers to THW3 1 Fasten standoffs provided into pem configuration A or C of backplane Fig 5 pg 6 2 Mount boards to standoffs uti...

Страница 7: ...es UL Listed in the U S and Canada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC battery sta...

Страница 8: ...8 TroveHW Notes...

Страница 9: ...25 375 644 6mm 19 375 492 1mm 12 625 320 7mm 0 45 11 4mm 1 0 25 4mm 1 0 25 4mm 9 2 233 7mm 8 5 215 9mm 16 25 412 8mm 0 156 3 96mm 9 2 233 7mm 7 5 190 5mm 0 45 11 4mm THW2 Dimensions H x W x D 25 375...

Страница 10: ...9 54mm 8 00 203 2mm 1 5 38 1mm 1 25 31 75mm 0 85 21 59mm 0 85 21 59mm 1 00 25 4mm 2 00 50 8mm 1 25 31 75mm 2 00 50 8mm 2 00 50 8mm 5 25 133 35mm 5 25 133 35mm 7 00 177 79mm 2 00 50 8mm 2 00 50 8mm 27...

Страница 11: ...11 0 45 11 4mm 2 5 63 5mm 2 50 8mm 13 5 342 9mm 13 5 342 9mm 13 5 342 9mm 25 635mm 0 156 3 96mm 1 0 25 4mm 1 0 25 4mm 34 863 6mm 28 711 2mm THW3 Dimensions H x W x D 34 x 28 x 0 3125 863 6mm x 711 2mm...

Страница 12: ...x W x D approximate 36 12 x 30 125 x 7 06 917 5mm x 768 1mm x 179 3mm G G 2 00 50 8mm 8 75 222 3mm 8 75 222 3mm 8 62 219mm 7 06 179 3mm 1 25 31 8mm 1 25 31 8mm 2 00 50 8mm 7 12 222 25mm 9 5 241 3mm 3...

Отзывы: