background image

 

- 2 -  

T3MKV Kits

Overview:

Altronix Trove Mercury kits are pre-assembled and consist of Trove3M3 enclosure/backplane with factory installed Altronix power 
supply/charger(s) and sub-assemblies. These kits also accommodate various combinations of Mercury boards for up to sixteen (16) doors 
in a single enclosure.

Configuration Chart:

Altronix

Model Number

220VAC 50/60Hz Input Current (A)

Power Supply Board Input Fuse Rating

Power Supply Board Battery Fuse Rating

Nominal DC Output Voltage

Maximum 

Supply

Current for 

Main and Aux. 

Outputs on Power 

Supply board 

and ACM8(CB) 

Access Power 

Controller’s 

outputs

Fail-Safe/Fail-Secure or  Dry Form “C” Outputs

Current Per  ACM8(CB) Output 

(A)

ACM8(CB) Board  Input Fuse Rating

ACM8 Board Output Fuse Rating

ACM8CB Board Output PTC Rating

PD8UL Board Output Fuse Rating

PD8ULCB Board Output Fuse Rating

Power Supply 1 Power Supply 2

[DC]

[Aux]

[DC]

[Aux]

Output Range  (VDC)

Output Range  (VDC)

Output Range  (VDC)

Output Range  (VDC)

T3MK75F16V

4.8

6.3A/250V

5A/250V

15A/

32V

20.17-

26.4

20.28-

26.4

9.7-

13.2

10.03-

13.2

12VDC @ 9.3A
24VDC @ 9.2A

16

2.5

10A/

250V

2.5A/
250V

3.5A/
250V

T3MK75F16DV

4.8

6.3A/250V

5A/250V

15A/

32V

20.17-

26.4

20.28-

26.4

9.7-

13.2

10.03-

13.2

12VDC @ 9.3A
24VDC @ 9.2A

16

2.5

10A/

250V

2A

2.5A

T3MK77F16V

5.4

6.3A/
250V

15A/

32V

20.17-

26.4

20.28-

26.4

20.17-

26.4

20.28-

26.4

24VDC @ 9.2A

16

2.5

10A/

250V

2.5A/
250V

3.5A/
250V

T3MK77F16DV

5.4

6.3A/
250V

15A/

32V

20.17-

26.4

20.28-

26.4

20.17-

26.4

20.28-

26.4

24VDC @ 9.2A

16

2.5

10A/

250V

2A

2.5A

Hardware and Accessories:

•  Two (2) tamper switches (Altronix Model TS112 or equivalent).
•  Cam lock.
•  Battery leads.

Mechanical:

•  16 Gauge enclosure with ample knockouts for convenient access.
•   Enclosure Dimensions (H x W x D): 36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm).

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having 
jurisdiction. Product is intended for indoor use only. 
1.  Remove backplane from enclosure. Do not discard hardware.
2.  Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws 
 

in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws, level and secure.

 

Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install 

 

the three fasteners. Place the enclosure’s upper keyholes over the three upper screws. 

 

Install the three lower screws and make sure to tighten all screws.

3.  Mount included UL Listed tamper switches (Altronix Model TS112 or equivalent) in desired location, 
 

opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2” 

 

from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input 

 

or the appropriate UL Listed reporting device. 

 

To activate alarm signal open the door of the enclosure.

4.  Mount Mercury boards to backplane, refer to pg. 3, 4.
5.  Refer to the eFlow Power Supply/Charger Installation Guide for eFlow104NBV, eFlow102NBV 
 

and corresponding Sub-Assembly Installation Guides for PD8UL(CB) and ACM8(CB) for 

 

further installation instructions.

6.  Position Mercury access controller module over corresponding spacers and depress onto 
 

snap on spacers (Fig. 2-3, pg. 3-4).

7.  Mount backplane to enclosure with hardware.

Fig. 1

Tamper Switch

(provided)

To Access Control Panel or

UL Listed Reporting Device

Edge of

Enclosure

Enclosure

Содержание TROVE T3MK75F16V

Страница 1: ...ne 1 eFlow104NBV Power Supply Charger One 1 eFlow102NBV Power Supply Charger Two 2 ACM8CB PTC Protected Access Power Controllers One 1 PD8ULCB PTC Protected Power Distribution Module One 1 Rocker Switch Bracket with Two 2 Rocker Switches T3MK77F16DV 16 Door Kit with PTC Outputs Fully assembled kit includes Trove3 enclosure with TM3 Altronix Mercury backplane Two 2 eFlow104NBV Power Supply Chargers...

Страница 2: ...for convenient access Enclosure Dimensions H x W x D 36 12 x 30 125 x 7 06 917 5mm x 768 1mm x 179 3mm Installation Instructions Wiring methods shall be in accordance with the National Electrical Code NFPA 70 ANSI and with all local codes and authorities having jurisdiction Product is intended for indoor use only 1 Remove backplane from enclosure Do not discard hardware 2 Mark and predrill holes i...

Страница 3: ... and depress onto snap on spacers Fig 2a pg 3 3 Mount backplane to enclosure with hardware Access Controller Position Chart for the Following Models Mercury Access Controller Pem Mounting EP1502 MR52 MR16IN MR16OUT A EP2500 MUX8 B EP1501 MR51e C MR52 D Altronix eFlow104NBV Altronix eFlow102NBV Altronix ACM8 CB Altronix ACM8 CB Altronix PD8UL CB D B B A A A A A A A A C RSB2 Bracket Rocker Switch Fi...

Страница 4: ...depress onto snap on spacers Fig 3a pg 4 3 Mount backplane to enclosure with hardware Access Controller Position Chart for the Following Models Mercury Access Controller Pem Mounting EP1502 MR52 MR16IN MR16OUT A EP2500 MUX8 B EP1501 MR51e C MR52 D Altronix eFlow104NBV Altronix eFlow104NBV Altronix ACM8 CB Altronix ACM8 CB Altronix PD8UL CB Altronix PD8UL CB D B B A A A A A A A A C RSB2 Bracket Roc...

Страница 5: ...T3MKV Kits 5 Notes ...

Страница 6: ...tures UL Listed in the U S and Canada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC battery status service input trigger state change output state change and unit temperature Access control and user managment Restrict read write Restrict users to specific resources Two 2 integral network con...

Страница 7: ...KV Kits 7 TM3 Dimensions 34 x 28 x 0 3125 863 6mm x 711 2mm x 7 9mm 0 45 11 4mm 2 5 63 5mm 2 50 8mm 13 5 342 9mm 13 5 342 9mm 13 5 342 9mm 25 635mm 0 156 3 96mm 1 0 25 4mm 1 0 25 4mm 34 863 6mm 28 711 2mm ...

Страница 8: ...mm 14 01 355 9mm 1 25 31 8mm 1 55 39 4mm 1 78 45 2mm 1 25 31 8mm 1 07 27 2mm 1 10 27 9mm 2 50 8mm 10 75 273 1mm 10 75 273 1mm 10 62 269 8mm 2 00 50 8mm 10 75 273 1mm 10 75 273 1mm 10 62 269 8mm 36 12 917 5mm 33 63 854 2mm Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 web site www altronix com e mail info alt...

Отзывы: