background image

 

- 4 -  

Trove Keri Systems Kits

T2KSK7F12: Installation Instructions for Keri Systems Access Controllers

1.  Fasten standoffs (provided) into pem configuration (A) or (B) of backplane (Fig. 2, pg. 3).
2.  Mount boards to standoffs utilizing 5/16” pan head screws (provided) (Fig. 2a, pg. 3).

 Note: Keri Systems NXT-2D-MSCNE and NXT-4D-MSCNE boards have one (1) RJ45 jack each. 

 

Please make sure that they are mounted correctly, as shown in Fig. 2 below. 

3.  Mount backplane to enclosure with hardware.
 

If use of NXTWI or NXTRM3 expansion boards is desired, there is no need to remove NXT-2D-MSCNE, NXT-4D-MSCNE or 

 

NXT-4X4NE from the TKS2.

Keri Systems Access Controller Position Chart for the Following Models:

Keri Systems Board

Pem Mounting

NXT-2D-MSCNE, NXT-4D-MSCNE

A

NXT-4X4NE

B

Pem

Standoff

Keri Systems

Board

Backplane

Pan Head

Screw

Fig. 2a

Altronix ACMS8

PWR1 +

PWR2 +

COM 

-

COM 

-

PWR2 +

PWR1 +

+ PWR2

 -- 

+ PWR1

 -- 

+ INP1

 -- 

DM1 +

OFF
IN1
IN2

Out1

<

1 off 

2>

DM1 +

DM2 +

DM2 +

Common (--- )

Common (--- )

+ INP2

 -- 

IN2 Fuse

IN1 Fuse

Common   Power   Outputs (NEG)

N

P

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

OUT8

 

8

10

10

3

3

3

3

3

3

3

3

Out2

<

1 off 

2>

Out3

<

1 off 

2>

Out4

<

1 off 

2>

Out5

<

1 off 

2>

Out6

<

1 off 

2>

Out7

<

1 off 

2>

Out8

<

1 off 

2>

Altronix PDS8

Altronix VR6 mounted under PDS8

Altronix

eFlow104NB

–   DC   

+

–   BAT   

+

L         G          N

TRG

TRIGGER

INPUT

ACM4

ACCESS POWER

CONTROLLER

LED1 

LED2 

LED3 

LED4

MAIN

OUTPUT 1

NC   C   NO  COM NC   C   NO  COM

NC   C   NO  COM NC   C   NO  COM

OUTPUT 2

OUTPUT 3

IN  GND

1

IN  GND

2

IN  GND

3

IN  GND

4

OUTPUT 4

-- 

       

+

CONTROL

-- 

       

+

POWER

+INP-      

T      +RET

-

INTERF

ACE

NO     C      NC

FACP

Altronix

ACM4

RJ45 Jack

RJ45 Jack

RJ45 Jack

A

A

A

B

B

B

Fig. 2

Содержание Trove T2KSK3F8

Страница 1: ...Altronix Keri Systems backplane One 1 eFlow104NB Power Supply Charger One 1 ACMS8 Dual Output Fused Access Power Controller One 1 VR6 Voltage Regulator One 1 PDS8 Dual Input Fused Power Distribution M...

Страница 2: ...rities having jurisdiction Product is intended for indoor use only 1 Remove backplane from enclosure Do not discard hardware 2 Mark and predrill holes in the wall to line up with the top two three key...

Страница 3: ...e TKS2 Keri Systems Access Controller Position Chart for the Following Models Keri Systems Board Pem Mounting NXT 2D MSCNE NXT 4D MSCNE A NXT 4X4NE B Pem Standoff Keri Systems Board Backplane Pan Head...

Страница 4: ...Models Keri Systems Board Pem Mounting NXT 2D MSCNE NXT 4D MSCNE A NXT 4X4NE B Pem Standoff Keri Systems Board Backplane Pan Head Screw Fig 2a Altronix ACMS8 PWR1 PWR2 COM COM PWR2 PWR1 PWR2 PWR1 INP...

Страница 5: ...Trove Keri Systems Kits 5 Notes...

Страница 6: ...6 Trove Keri Systems Kits Notes...

Страница 7: ...2 Features UL Listed in the U S and Canada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC bat...

Страница 8: ...oximate 27 25 x 21 75 x 6 5 692 2mm x 552 5mm x 165 1mm G 1 25 31 75mm 1 25 31 75mm 6 25 158 75mm 6 25 158 75mm 6 75 171 45mm 8 25 209 54mm 8 00 203 2mm 1 5 38 1mm 1 25 31 75mm 0 85 21 59mm 0 85 21 59...

Отзывы: