background image

 

- 4 - 

T1RAL13F8P8 Installation Guide

Assembling and Attaching 

Z Bracket Wire Management Accessory 

(included)

:

Altronix Trove Rack enclosures include Z Bracket, a convenient and reliable wire management accessory.

 

Hardware 

(included)

:

 

 

Ten (10) bolts and 

eight (8) lock nuts.

1.  Carefully unpack Z Bracket. Do not discard hardware 

 (included) 

(Fig. 3, pg. 4)

.

2.  Attach arms to each other using bolts and 

  lock nuts 

(Fig. 3a, pg. 4)

.

3.  Attach the hinge brackets to the ends of 

 arms using bolts and nuts positioning 

  them as shown on 

(Fig. 3b, pg. 4)

.

4.  Make sure that all nuts are tightened.

5.  Attach the hinge bracket on the longer side of Z Bracket to the adjustable slide using bolts and lock nuts 

 (included) 

(Fig. 4, 4a, pg. 4)

.

6.  Attach the hinge bracket on the shorter side of Z Bracket to the rear of the rack enclosure using bolts 

 (included).

Fig. 4

Fig. 4a

Fig. 3b

Two (2)

Fig. 3

Fig. 3a

Содержание TROVE T1RAL13F8P8

Страница 1: ...f their respective owners T1RAL13F8P8 8 Door Kit with Fused Outputs Fully assembled kit includes Trove1R rack enclosure with Altronix backplane TAL1R 1 eFlow4NB Power Supply Charger 1 eFlow6NB Power Supply Charger 1 ACM8 Fused Access Power Controller 1 PD8UL Fused Power Distribution Module All components of this Trove kit are UL Listed sub assemblies Please refer to the included corresponding Sub ...

Страница 2: ...Fuse Rating PD8UL Board Input Fuse Rating PD8UL Board Output Fuse Rating DC Aux Output Range VDC Output Range VDC T1RAL13F8P8 7 5A 250V 10A 32V Power Supply 1 24VDC 8 8 2 5A 15A 32V 3 5A 250V 3 5A 250V 20 19 26 4 20 19 26 4 24VDC 5 7A Power Supply 2 12VDC 10 0 13 2 10 1 13 2 12VDC 4A Specifications Agency Listings CE European Conformity Mechanical Black enclosure with ample knockouts for convenien...

Страница 3: ...er with the button facing outwards and spaded connectors inside the drawer Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device To activate alarm signal open the rack drawer 3 Slide the rack enclosure into an open 2U location in the four post rack cabinet 4 Utilizing proper fasteners attach front ears to the rack rails 5 Attach the rear of th...

Страница 4: ...uded Fig 3 pg 4 2 Attach arms to each other using bolts and lock nuts Fig 3a pg 4 3 Attach the hinge brackets to the ends of arms using bolts and nuts positioning them as shown on Fig 3b pg 4 4 Make sure that all nuts are tightened 5 Attach the hinge bracket on the longer side of Z Bracket to the adjustable slide using bolts and lock nuts included Fig 4 4a pg 4 6 Attach the hinge bracket on the sh...

Страница 5: ... 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 INPUT TRIGGER 10A 250V INP T RET NO C NC FACP INTERFACE Power Control F1 F2 F3 F4 F5 F6 F7 F8 MAIN TRG FACP 1 2 3 4 1 2 3 4 O N O N 1 2 3 4 1 2 3 4 O N O N Altronix ACM8 N C O M M O N P O W E R...

Страница 6: ... 6 T1RAL13F8P8 Installation Guide Notes ...

Страница 7: ...T1RAL13F8P8 Installation Guide 7 Notes ...

Страница 8: ... 38 1mm 11 175 283 8mm 2 4 61mm 4 57 116 1mm 3 375 85 8mm 26 5 673 1mm 19 482 6mm R 1 27 32 3mm 1 25 4mm 0 55 14mm 3 62 92mm Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 website www altronix com e mail info altronix com Lifetime Warranty IIT1RAL13F8P8 I01U MEMBER ...