- 2 -
T1RAL13F8P8 Installation Guide
Overview:
Altronix T1RAL13F8P8 Trove Rack kit is pre-assembled and consist of Trove1AL1R enclosure/backplane with
factory installed Altronix power supply/chargers and sub-assemblies.
Configuration Chart:
Altronix
Model
Number
120VAC 60Hz Input Current (A)
Power Supply Boards’ Input Fuse Rating
Power Supply Boards’ Battery Fuse Rating
Nominal DC
Output Voltage Maximum Supply
Current for Main
and Aux. Outputs
on Power Supply
board and ACM8
Access Power
Controller’s
outputs
Fail-Safe/Fail-Secure or Dry Form “C” Outputs Additional Fuse Protected Outputs Current Per ACM8 Output ACM8 Board Input Fuse Rating ACM8 Board Output Fuse Rating PD8UL Board Input Fuse Rating PD8UL Board Output Fuse Rating
[DC]
[Aux]
Output
Range
(VDC)
Output
Range
(VDC)
T1RAL13F8P8
7
5A/
250V
10A/
32V
Power Supply 1 (24VDC)
8
8
2.5A 15A/
32V
3.5A/
250V –
3.5A/
250V
20.19-
26.4
20.19-
26.4
24VDC @ 5.7A
Power Supply 2 (12VDC)
10.0-
13.2
10.1-
13.2
12VDC @ 4A
Specifications:
Agency Listings:
• CE European Conformity.
Mechanical:
• Black enclosure with ample knockouts for
convenient access.
• Includes: tamper switch, cam lock and
mounting hardware.
• Modular 2U standard EIA 19” drawer with
extendable slides up to 48”.
• Dimensions (H x W x D): 3.375” x 19.0” x 26.5”
(85.8mm x 482.6mm x 673.1mm)
Included Accessories:
• One (1) tamper switch
(Altronix Model TS112 or equivalent).
• Cam lock.
Available Accessories
(not included)
:
•
RE2:
Rack Mount Battery Enclosure accommodates
up to four (4) 12VDC/7AH batteries.
•
WM5, WM25, WM100:
Magnetic Cable Tie Mounts
(5, 25, 100 counts).