background image

- 4 -  

T1MK Kits

Altronix

eFlow4NB

–   DC   +

–   BAT   +

TRG

TRIGGER

INPUT

ACM4

ACCESS POWER

CONTROLLER

LED1 

LED2 

LED3 

LED4

MAIN

OUTPUT 1

NC   C   NO  COM NC   C   NO  COM

NC   C   NO  COM NC   C   NO  COM

OUTPUT 2

OUTPUT 3

IN  GND

1

IN  GND

2

IN  GND

3

IN  GND

4

OUTPUT 4

-- 

       

+

CONTROL

-- 

       

+

POWER

+INP-      

T      +RET

-

INTERF

ACE

NO     C      NC

FACP

Altronix ACM4(CB)

Altronix PDS8(CB)

+ INP1

 -- 

DM1 +

OFF
IN1
IN2

Out1

<

1 off 

2>

DM1 +

DM2 +

DM2 +

Common (--- )

Common (--- )

+ INP2 

-- 

IN2 Fuse

IN1 Fuse

Common   Power   Outputs (NEG)

N

P

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

OUT8

 

8

Out2

<

1 off 

2>

Out3

<

1 off 

2>

Out4

<

1 off 

2>

Out5

<

1 off 

2>

Out6

<

1 off 

2>

Out7

<

1 off 

2>

Out8

<

1 off 

2>

A

B

C

D

D

C

B

A

T1MK1F4S and T1MK1F4SD: Configuration of Mercury Boards:

1.  Fasten snap on standoffs onto metal pems configuration (A), (B), (C) or (D) of backplane depending on the access controller (Fig. 3, pg. 4).
2.  Position access controller module over corresponding standoffs and depress onto snap on standoffs (Fig. 3a, pg. 4).
3.  Mount backplane to enclosure with hardware.

Access Controller Position Chart for the Following Models:

Mercury Access Controller

Pem Mounting

EP1502, LP1502, MR52, MR16IN, MR16OUT

A

EP1501, LP1501, MR51e, MR62e

B

MR50

C

EP2500, LP2500, MUX8

D

Fig. 3

Snap On

Standoff

Mercury Board

Backplane

Pem

Fig. 3a

Отзывы: