Sav4/9/18/182/36D 

 - 3 -

  turn trimpot clockwise to increase voltage or counter clockwise to decrease voltage.

 

Note: Voltage will be the same for all outputs.

4.  Connect cameras to be powered to the terminals marked [OUT1 through OUT4 (Sav4D)] (Fig. 2, pg. 4), [OUT1  

 

  through OUT9 (Sav9D)] (Fig. 3, pg. 5), [OUT1 through OUT18 (Sav18D)] (Fig. 4, pg. 6), [OUT1 through OUT9 on

  each power supply board (Sav182D)] (Fig. 5, pg. 7), [OUT1 through OUT18 on each power supply board (Sav36D)]

  (Fig. 6, pg. 8), carefully observing correct polarity.

5.  Upon completion of wiring, secure enclosure door with screws (supplied).

 

Caution: Equipment to be installed/serviced by authorized/trained personnel only and should conform to all 

  local codes and in accordance with the National Electrical Code. Shut branch circuit power before

  installing/servicing equipment.

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.

Use 75˚C or higher rated UL insulated wiring for connecting the unit to the mains.

Maintenance:

Unit should be tested at least once a year for the proper operation as follows:
Output Voltage Test: Under normal load conditions, the DC output voltage should be checked for proper voltage level.

Terminal Identification:

Model

Terminal Legend

Description

All

L, G, N

115VAC, 60 Hz / 230VAC, 50 Hz Input

Sav4D

OUT1 (-- , +) through OUT4 (-- , +)

12VDC power output.

Sav9D

OUT1 (-- , +) through OUT9 (-- , +)

Sav18D

OUT1 (--  , +) through OUT18 (--  , +)

Sav182D

OUT1 (--  , +) through OUT9 (--  , +)
(on both power supply boards)

Sav36D

OUT1 (--  , +) through OUT18 (--  , +)
(on both power supply boards)

LED Identification:

Model

LED

ON

OFF

All

AC

Normal operating condition.

Loss of AC, No DC output

Sav4D

OUT1 through OUT4

Normal operating condition.

No Power Output.

Sav9D

OUT1 through OUT9

Sav18D

OUT1 through OUT18

Sav182D

OUT1 through OUT9
(on both power supply boards)

Sav36D

OUT1 through OUT18
(on both power supply boards)

    

Содержание Sav182D

Страница 1: ...5 amp Nine 9 Class 2 Rated PTC Protected Power Limited Outputs Sav18D 12VDC 5 amp Eighteen 18 Class 2 Rated PTC Protected Power Limited Outputs Sav182D 12VDC 11 amp Eighteen 18 Class 2 Rated PTC Prot...

Страница 2: ...s upper keyholes over the two upper screws level and secure Mark the position of the lower two holes Remove the enclosure Drill the lower holes and install two fasteners Place the enclosure s upper k...

Страница 3: ...reduce the risk of fire or electric shock do not expose the unit to rain or moisture Use 75 C or higher rated UL insulated wiring for connecting the unit to the mains Maintenance Unit should be teste...

Страница 4: ...maintenance servicing instructions in the literature accompanying the appliance CAUTION To reduce the risk of electric shock do not open enclosure There are no user serviceable parts inside Refer serv...

Страница 5: ...Keep power limited wiring separate from non power limited Use minimum 0 25 spacing Door Wire Strap from Enclosure to Door 12VDC power outputs For wiring utilize knockouts on the right hand side of en...

Страница 6: ...Keep power limited wiring separate from non power limited Use minimum 0 25 spacing Door Wire Strap from Enclosure to Door 12VDC power outputs For wiring utilize knockouts on the right hand side of en...

Страница 7: ...12VDC power outputs For wiring utilize knockouts on the right hand side of enclosure Class 2 not wet Class 3 wet wiring to be used 115VAC 60Hz 230VAC 50Hz power mains non power limited Class 1 Keep p...

Страница 8: ...d 12VDC power outputs For wiring utilize knockouts on the right hand side of enclosure Class 2 not wet Class 3 wet wiring to be used Keep power limited wiring separate from non power limited Use minim...

Страница 9: ...servicing Do not attach the 3 wire line cord to the building surface 1 Remove 7 8 knockout by applying pressure from the inside of enclosure Fig 7 Note Keep power limited wiring separate from non powe...

Страница 10: ...ice black lead from line cord to black leads from each power supply board utilizing wire nut Fig 12 Splice green lead from line cord to green flying lead in the enclosure utilizing wire nut Fig 12 Spl...

Страница 11: ...mm x 88 9mm 1 25 31 75mm 1 25 31 75mm 1 25 31 75mm 1 125 28 575mm 1 25 4mm 1 25 4mm 1 25 4mm 5 25 133 35mm 6 05 153 67mm 6 05 153 67mm 3 5 88 9mm 3 5 88 9mm 7 25 184 15mm 2 50 8mm 2 50 8mm 8 125 206 3...

Страница 12: ...com Made in U S A IISAV4D SAV9D SAV18D SAV182D SAV36D H14N Enclosure Dimensions for Sav182D and Sav36D 13 5 x 13 x 3 25 342 9mm x 330 2mm x 82 55mm 1 40 36mm 1 40 36mm 4 85 123mm 4 85 123mm 1 40 36mm...

Отзывы: