Sav4/9/18/182/36D
- 3 -
turn trimpot clockwise to increase voltage or counter clockwise to decrease voltage.
Note: Voltage will be the same for all outputs.
4. Connect cameras to be powered to the terminals marked [OUT1 through OUT4 (Sav4D)] (Fig. 2, pg. 4), [OUT1
through OUT9 (Sav9D)] (Fig. 3, pg. 5), [OUT1 through OUT18 (Sav18D)] (Fig. 4, pg. 6), [OUT1 through OUT9 on
each power supply board (Sav182D)] (Fig. 5, pg. 7), [OUT1 through OUT18 on each power supply board (Sav36D)]
(Fig. 6, pg. 8), carefully observing correct polarity.
5. Upon completion of wiring, secure enclosure door with screws (supplied).
Caution: Equipment to be installed/serviced by authorized/trained personnel only and should conform to all
local codes and in accordance with the National Electrical Code. Shut branch circuit power before
installing/servicing equipment.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
Use 75˚C or higher rated UL insulated wiring for connecting the unit to the mains.
Maintenance:
Unit should be tested at least once a year for the proper operation as follows:
Output Voltage Test: Under normal load conditions, the DC output voltage should be checked for proper voltage level.
Terminal Identification:
Model
Terminal Legend
Description
All
L, G, N
115VAC, 60 Hz / 230VAC, 50 Hz Input
Sav4D
OUT1 (-- , +) through OUT4 (-- , +)
12VDC power output.
Sav9D
OUT1 (-- , +) through OUT9 (-- , +)
Sav18D
OUT1 (-- , +) through OUT18 (-- , +)
Sav182D
OUT1 (-- , +) through OUT9 (-- , +)
(on both power supply boards)
Sav36D
OUT1 (-- , +) through OUT18 (-- , +)
(on both power supply boards)
LED Identification:
Model
LED
ON
OFF
All
AC
Normal operating condition.
Loss of AC, No DC output
Sav4D
OUT1 through OUT4
Normal operating condition.
No Power Output.
Sav9D
OUT1 through OUT9
Sav18D
OUT1 through OUT18
Sav182D
OUT1 through OUT9
(on both power supply boards)
Sav36D
OUT1 through OUT18
(on both power supply boards)