Enclosure Dimensions:

17.375” x 12” x 6.5” (441.3mm x 304.8mm x 165.1mm).

16’’

406mm

6.5’’

165.1mm

17.375’’

441.3mm

10’’

254mm

16.75’’

425.45mm

12’’

304.8mm

10.875’’

276.2mm

14.875’’

377.83mm

0.3125’’

7.9375mm

0.5’’

12.7mm

4.5’’

114.3mm

Fig. 4

Fig. 5

Fig. 6

5.  Mount enclosure onto the top bracket by inserting bolts through flange of the enclosure 
 

and into the bracket, tightening bolts with a 7/16” hex socket (Fig. 7, pg. 4).

6.  Tighten the straps of the bottom bracket down by sliding the open end of
 

the strap through the locking mechanism on the strap, then tighten screw

 

with flat head screwdriver or 5/16” hex socket driver (Fig. 8/8a, pg. 4).

7.  Clip excess straps.

Fig. 8 -   2” to 8”(50.8mm to 203.2mm) 

Fig. 8a - 5” (127mm)

 

 

diameter round pole 

square pole

Fig. 7

MEMBER

Содержание ReServ4WPV

Страница 1: ...to outputs This helps avoiding potential damage 8 Connecting Fluidmesh Wireless Radio Bosch Autodome Connect 12VDC Fluidmesh Wireless Radio to the terminals marked P 1 2 N 1 2 Fig 2 pg 3 Connect 24VAC Bosch Autodome to the terminals marked 15 16 Fig 2 pg 3 9 Connect batteries to the terminals marked BAT Fig 2 pg 3 Use two 2 12VDC batteries connected in series for 24VDC operation battery leads incl...

Страница 2: ...se terminals L to hot N to neutral DC 24VDC output AC FAIL NO C NC Form C dry contacts used to instantaneously signal the loss AC to local annunciation devices With AC present terminals marked NO and C are open NC and C are closed When loss of AC occurs terminals marked NO and C are closed NC and C are open BAT FAIL NO C NC Form C dry contacts used to signal low battery voltage or loss of battery ...

Страница 3: ...e personnel This product contains no serviceable parts PMK1 is intended for use with Altronix outdoor rated power supplies or accessories housed in WP1 WP2 WP3 and WP4 enclosures Brackets are designed for use with the Wormgear Quick Release Straps two included 1 Thread one 1 wormgear quick release strap through the slots on the back of a mounting bracket Fig 4 pg 4 2 Once the desired height of the...

Страница 4: ...441 3mm 10 254mm 16 75 425 45mm 12 304 8mm 10 875 276 2mm 14 875 377 83mm 0 3125 7 9375mm 0 5 12 7mm 4 5 114 3mm Fig 4 Fig 5 Fig 6 5 Mount enclosure onto the top bracket by inserting bolts through flange of the enclosure and into the bracket tightening bolts with a 7 16 hex socket Fig 7 pg 4 6 Tighten the straps of the bottom bracket down by sliding the open end of the strap through the locking me...