background image

Match 

lite

Uninterruptible Power Supply
500 VA

Manufactured by:

GE Digital Energy

General Electric Company 

Tel41 (0)91 / 850 51 51

CH – 6595 Riazzino (Locarno)

Fax

+41 (0)91 / 850 51 44

Switzerland

Website

www.gedigitalenergy.com

GE Digital Energy

Technology for the Digital World.

ver 4.0 - GB

Match lite UPS

g

Содержание Match lite 500

Страница 1: ...factured by GE Digital Energy General Electric Company Telephone 41 0 91 850 51 51 CH 6595 Riazzino Locarno Fax 41 0 91 850 51 44 Switzerland Website www gedigitalenergy com GE Digital Energy Technology for the Digital World ver 4 0 GB Match lite UPS g ...

Страница 2: ...les 2 2 Installation Procedure 3 OPERATION 3 3 1 Start up 3 1 1 Start up mains available 3 1 2 Start up mains not available 3 2 Use Normal Operation 3 2 1 Normal operating conditions 3 2 2 Self test 3 2 3 Switching off 3 3 Use Status and Alarm Indications 3 3 1 Charger on 3 3 2 Normal operation 3 3 3 On battery 3 3 4 Battery low 3 3 5 Replace battery 3 3 6 Overload 3 3 7 Shutdown 4 COMMUNICATION 6...

Страница 3: ...nect the unit to a wall outlet for a period of approx 48 hours minimum every 3 months The shipping box contains a Match lite UPS a power cord a computer interface cable and this manual After unpacking inspect the UPS for damage If you find any damage please immediately notify the carrier and place of purchase IMPORTANT Before making any connection and switching on the Match lite UPS please check t...

Страница 4: ...2 seconds LED LINE already blinking will illuminate continuously now 2 The equipment connected to the UPS can now be switched on 3 1 2 Start up mains not available If the mains input is absent power cord not connected or mains failure 1 Press keypad ON TEST for 4 seconds until LED BAT illuminates The UPS operates on battery it discharges the batteries 3 2 Use Normal Operation 3 2 1 Normal operatio...

Страница 5: ...mmediate action should be taken Situation LINE BAT buzzer o Charger on 3 3 1 1x s o Normal operation 3 3 2 On battery 3 3 3 1x 4s Battery low 3 3 4 1x s 1x s Replace battery 3 3 5 1x 30s 1x 30s Overload 3 3 6 o Shutdown 3 3 7 1x s Operating modes and corresponding indications see 3 3 1 3 3 7 intermitting continuous resetable press button ON TEST briefly Only the current alarm is muted a next alarm...

Страница 6: ...hutdown of your computer equipment should be completed within 1 minute 3 3 5 Replace battery The battery is bad Perform the self test again to confirm the replace battery condition The alarm only goes out after the next self test if the battery has either been sufficiently charged discharged battery or replaced by a new one worn out battery See also 5 3 3 3 6 Overload The demanded power of the equ...

Страница 7: ...hen the condition of the battery is critical a replace battery alarm will be generated see 3 3 Charge the batteries for at least 10 hours switch the UPS off and back on and perform a self test If the alarm persists replace the batteries as soon as possible 5 3 2 Battery replacement Warning first read the safety rules in section 1 2 When replacing the batteries use the same number and voltage V cap...

Страница 8: ...blinks UPS is in programmed shutdown mode Normal situation UPS will not switch on nor off Computer interface problem Disconnect interface If this solves the problem check interface cable and attached computer UPS will not switch on LEDs LINE and BAT blink Software configuration error Disconnect mains press OFF during 2 seconds to reset the internal processor Blown input fuse See above UPS operates...

Страница 9: ...e of battery start last detected frequency off factory 50 Hz Output frequency stability 0 1Hz battery operation Output waveform step sine wave Power factor 0 6 0 7 at 90 load Transfer time typical 4 ms max 10 ms Buck Boost voltage regulation at 165 275 V input voltage output voltage 190 254V Batteries ratings given for 25 C Nominal voltage Vdc 12 Number x capacity Ah of batteries 1x7 Type 12V seal...

Отзывы: