background image

ReServ1

- 1 -

Overview:

ReServ1 Video Surveillance UPS is designed to simultaneously provide power for 12VDC and 24VAC cameras during
normal or power outage conditions. True sine wave regulated AC output.

Specifications:

Input:

• 115VAC 60 Hz, 1.9 amps.

Output:

• 12 individually fuse protected outputs

configured as follows:
• Eight (8) outputs @ 24VAC.
• Four (4) outputs @ 12VDC

.

• Unit will provide:

• Blade type output fuses are rated at:

AC fuses rated @ 3 amp / 32V.
DC fuses rated @ 3 amp / 32V.

Battery Backup:

• Built-in charger for sealed lead acid or gel type batteries. 
• Automatic switchover to stand-by battery

when AC fails.

Visual Indicators:

• AC/DC power LED indicators.
• Individual power LED indicators.
• Low voltage input and

Shutdown LED indicators.

Supervision:

• AC fail supervision (form "C" contacts). 
• Low battery supervision (form "C" contacts). 

Special Features:

• True sine wave regulated AC output.
• Power ON/OFF switch.
• Spare fuses included.
• Unit maintains camera synchronization. 
• Ease of installation saves time and eliminates costly labor.

Enclosure:

• Enclosure accommodates up to two (2)

12VDC/7AH batteries.

• Enclosure dimensions:

13.5"H x 13"W x 3.25"D

Installation Instructions:

1. Mount unit in desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the

enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s
upper keyholes over the two upper screws, level and secure. 
Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. 
Place the enclosure’s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten 
all screws 

(Enclosure Dimensions, pg. 4)

. Secure enclosure to earth ground. 

2. Slide power switch to OFF position 

(Fig. 1a, pg. 2)

.

3. Connect AC power mains to terminals marked [L & N], connect ground to terminal marked [G] 

(Fig. 1, pg. 2)

.

Use 18 AWG or larger for all power connections (Battery, DC output)

(Fig. 1, pg. 2)

.

Use 18 AWG to 22 AWG for power limited circuits (AC Fail/Low Battery reporting)

(Fig. 1b, pg. 2)

.

4. Slide power switch to ON position 

(Fig. 1a, pg. 2)

.

5. Measure output voltage before connecting devices. This helps avoid potential damage.
6. Slide power switch to OFF position 

(Fig. 1a, pg. 2)

.

7. Connect devices to output terminals using the following procedure.

Connect 24VAC cameras to terminals marked [24VAC, N-P] 

(Fig. 1c, pg. 2)

.

Connect 12VDC cameras to terminals marked [12VDC, + 1 --   ] carefully observing the correct polarity

(Fig. 1d, pg. 2)

.

8. Slide power switch to ON position 

(Fig. 1a, pg. 2)

.

9. Green LED on the power supply board will illuminate when power is present.
10. Upon completion of wiring, secure enclosure door with screws (supplied).

WARNING:

To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This instal-

lation should be made by qualified service personnel and should conform to all local codes and in accordance
with the National Electrical Code.

ReServ1 - Video Surveillance UPS

24VAC Output

12VDC Output

4 amp (max.)

---

3.5 amp (max.)

1 amp (max.)

3 amp (max.)

2 amp (max.)

Содержание ReServ1

Страница 1: ...el and secure Mark the position of the lower two holes Remove the enclosure Drill the lower holes and install the two fasteners Place the enclosure s upper keyholes over the two upper screws Install the two lower screws and make sure to tighten all screws Enclosure Dimensions pg 4 Secure enclosure to earth ground 2 Slide power switch to OFF position Fig 1a pg 2 3 Connect AC power mains to terminal...

Страница 2: ...W BATTERY SHUTDOWN Protected outputs Common outputs OUT1 OUT2 OUT3 OUT4 24 VAC outputs 1 2 3 4 5 6 7 8 N P IC4 12VDC Aux Out Input 24VDC Fig 1a Fig 1b Fig 1c Fig 1d Fuse Replacement 1 Before replacing fuses slide switch to OFF position 2 Replace AC outputs fuses F1 or F4 with fuses rated 3 amp 32V Replace DC outputs fuses F1 or F4 with fuses rated 3 amp 32V Automotive Blade Fuse OUT1 OUT2 OUT3 OUT...

Страница 3: ...o alarm panel NO C NC Relay normally energized when DC power is present Contact rating 1 amp 28VDC Low battery threshold 24VDC output threshold set approximately 21VDC BAT Stand by battery connections Maximum charge rate 5 amp Terminal Legend Function Description Input 24VDC from OLS120 power supply charger 24VAC N P 1 8 24VAC outputs 12VDC 1 to 4 12VDC outputs Red DC Green AC Power Supply Status ...

Страница 4: ... York 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Made in U S A IIReServ1 Rev 120108 B26I MEMBER 5 10 6 5625 3 25 3 25 5 10 5 10 3 25 1 00 10 50 1 00 1 00 1 00 1 40 1 20 1 40 1 20 0 75 0 75 11 00 12 50 3 25 0 9375 0 9375 1 40 4 85 4 85 1 40 1 20 Bottom Top Right Left Enclosure Dimensions 13 5 H x 13 W x 3 25 D ...

Отзывы: