R615DCUL Series

Overview:

Altronix R615DCUL Series Rack Mount CCTV Power Supplies provide 6-15VDC distributed via eight (8) or 
sixteen (16) fuse or PTC protected outputs for powering CCTV cameras, heaters, and other video accessories.

R615DCUL Rack Mount Configuration Reference Chart:

Altronix
Model Number

Total 

Output 

Current 

(Power)

Output 

Voltage

Number of 

Outputs

Class 2 

Rated 

Power- 

Limited

Outputs

PTC 

Protected

Outputs

(auto-

resettable)

Fuse 

Protected

Outputs

Output 

Current

(max per 

output)

115VAC 

50/60Hz 

Input 

Current

R615DC8UL

4A

6-15VDC

8

P

P

3.5A

0.9A

R615DC8ULCB

4A

6-15VDC

8

P

P

2.5A

0.9A

R615DC416UL

4A

6-15VDC

16

P

P

3.5A

0.9A

R615DC416ULCB

4A

6-15VDC

16

P

P

-

2.5A

0.9A

R615DC616UL

6A

6-15VDC

16

P

3.5A

1.5A

R615DC616ULCB

6A

6-15VDC

16

P

P

2.5A

1.5A

Specifications:

Installation Instructions:

1.  Unit is factory set at 12VDC. To adjust the output voltage remove the top cover to access trimpot on the 
 

power supply board (Fig. 1b, pg. 3).

2.  Mount unit in the desired rack location (Space unit at least 3” from any video monitors).
3.  Set power switch on the back of the unit to the OFF position (Fig. 1e, pg. 3).
4.  Plug the power cord into a grounded 115VAC 50/60 Hz receptacle (Fig. 1d, pg. 3).
5.  Set power switch to the ON (RESET) position and measure output voltage before connecting devices 
 (Fig. 1e, pg. 3). This helps avoiding potential damage.
 

CAUTION: Determine the maximum operating voltage of the equipment being powered before 

 

adjusting the output voltage.

6.  Set power switch on the back of the unit to the OFF position (Fig. 1e, pg. 3).
7.  Connect devices to the removable terminal blocks marked [1P & 1N] through [8P & 8N] or 
 

[1P & 1N] through [16P & 16N], where applicable (Fig. 1c, pg. 3).

 

When wiring is completed on the terminal blocks, they can be locked down by tightening screw flanges.

 

All terminals with common suffix (P) “1P, 2P...” are the same polarity (positive).

 

All terminals with common suffix (N) “1N, 2N...” are the same polarity (negative).

8.  Upon completion of the wiring, set power switch on the back of the unit to the ON (RESET) position 
 

(Fig. 1e, pg. 3).

9.  Green power LEDs on faceplate will illuminate when DC output power is present. When an output is in a 
 

trouble condition (blown fuse or tripped PTC), the corresponding LED will not be illuminated (Fig. 1, pg. 3).

 

a.  Blown fuse (R615DC416UL, R615DC616UL, and R615DC8UL) - Set power switch on the back of 

 

  unit to the OFF position (Fig. 1e, pg. 3). Remove front faceplate to access fuses. 

 

  Replace with fuses rated @ 3.5A/250VA (Altronix model # Fuse1).

 

b.  Tripped PTC (R615DC416ULCB, R615DC616ULCB, and R615DC8ULCB) - To reset PTC, set power 

 

  switch on the back of the unit to the OFF position (remove overloaded circuit condition prior to reset).

 

  After approximately 30 secs. set power switch to the ON (RESET) position (Fig. 1e, pg. 3).

Agency Listings:

• 

UL 2044 

Commercial CCTV Equipment.

• 

CSA Standard C22.2 No.1-98

   

Audio, Video and Similar Equipment.

• 

CE 

European Conformity.

Input:

•  115VAC, 50/60Hz.

Output:

•  Eight (8) or sixteen (16) fuse or 
  PTC protected outputs 
•  6-15VDC output.
•  Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
•  Filtered and electronically regulated outputs.
•  Short circuit and thermal overload protection.

Features:

•  Individual power LED indicators.
•  Illuminated master power disconnect circuit breaker
  with manual reset.
•  Removable terminal blocks with locking 
  screw flange.
•  Removable faceplate and sliding rear section for
  easy access.

Rack Dimensions:

•  2U rack mount chassis for use in standard 
  EIA 19” rack.
•  Rack dimensions (H x W x D approx.):
  3.26” x 19.125” x 8.5” (83mm x 486mm x 216mm).