NetWaySP4P / NetWaySP4P2

Overview:

Altronix NetWaySP4P/NetWaySP4P2 Fiber Optic Transceivers provide four (4) 1Gb SFP ports and four (4) ports for up to 120W per port to be transmitted over composite fiber (powered) 
cable (fiber + copper combined) to NetWay Spectrum PoE Hardened Switches. NetWaySP4P/NetWaySP4P2 can be used for standard fiber cable applications as well.

Specifications:

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction. NetWaySP4P/NetWaySP4P2 is not 
intended to be connected to outside plant leads. These products are for indoor use only and must be installed within the
protected premises. NetWaySP4P must be installed in a restricted access area. NetWaySP4P2 if battery bracket is removed,
then the unit must be installed in a restricted access area (Fig. 1b, pg. 2). The outputs are of a non-limited power source.
For non-limited power sources, additional protective circuitry and/or an appropriate fire
enclosure for the products supplied by this device are required.
1.  Attach mounting brackets to the unit for rack or wall mount installation (Fig. 4 or 5, pg. 4). Affix rubber pads to the unit
 

for shelf installation (Fig. 6, pg. 4).

2.  Secure the unit in a rack or on a wall, or place unit on a shelf as desired.
 

Note: The following factors should be taken into consideration when installing these rack mount units:

 

  a. The unit is to be installed in a space where the maximum ambient temperature does not exceed 104ºF (40ºC).

 

  b. Take care to ensure that there is sufficient air flow around the unit and that obstructions do not impede it.

 

  c. When mounting units in a rack, take care to avoid uneven loading which can cause a hazardous condition.

3.  Plug the grounded AC line cord (included) into the IEC 320 connector of the unit (Fig. 2f, pg. 3). Plug unit into a reliable earth grounded socket. 
 

When using multiple units, the sum of the individual name plate ratings should not exceed the supply circuit rating. 

 

Do not connect to a receptacle controlled by a switch.

4.  Connect structured cable from ethernet switch/NVR (network video server) to RJ45 jack marked [Ethernet 1-4] (Fig. 2e, pg. 3).
 

Note: All cabling and wire must be UL Listed and/or Recognized wire suitable for their application.

5.  Connect Composite (Powered) Fiber cable, fiber portion to port marked [SFP 1-4], copper portion connects to output marked [OUT 56VDC, 1-4] (Fig. 2b & 2d, pg. 3)
6.  Connect opposite end of Composite (Powered) Fiber cable, fiber portion to SFP port on NetWay Spectrum Hardened Switch, copper portion connects to power input of
 

NetWay Spectrum Hardened Switch, 

carefully observing correct polarity (Refer to NetWaySP3WPN/4WPN/8WPN / NetWay4EWPN Installation Instructions).

Agency Listings:

•  UL/cUL Listed for Information Technology Equipment (UL 60950-1).
•  CE approved.

Input:

•  115VAC, 60Hz, 3.25A or 230VAC, 50/60Hz, 2A.

Power:
NetWaySP4P:

•  Four (4) 56VDC non power-limited outputs up to 120W max. full power per port.
  Total power: 240W.
•  IEEE 802.3af and IEEE 802.3at compliant (PoE/PoE+).
•  Short circuit protection.

NetWaySP4P2:

•  Four (4) 56VDC power-limited outputs up to 60W max. full power per port.
  Total power: 240W.
•  Short circuit protection.

Fiber Port:

•  Four (4) Gigabit SFP ports.
•  Use with SFP module 1000Base-X (1Gb), compliant to
  Class 1 laser product (not included).

Ethernet:

•  Four (4) ports to swtich.
•  Wire type: 4-pair CAT5e and higher.
•  Connectivity: RJ45, auto-crossover.
• Speed: 10/100/1000Mbps.
•  Distance: up to 100m.

Environmental:

•  Refer to Environmental Conditions on page 3.

Battery Backup:

•  Built-in battery charger (optional rack mount battery enclosure - RE2).
•  Automatic switchover to stand-by battery when AC fails. 

Compatible PoE Hardened Switches and Accessories:

NetWaySP3WPN:   

3-port PoE Hardened Switch with (1) SFP port.

NetWay4EWPN: 

  4-port PoE Hardened Switch with (1) SFP port.

NetWaySP4WPN:   

4-port PoE Hardened Switch with (2) SFP ports.

NetWaySP8WPN:   

8-port PoE Hardened Switch with (2) SFP ports.

RE2:  

Rack Mount Battery Enclosure accommodates up to four (4) 12VDC/7AH batteries

Fig. 1a 

Fig. 1b

Содержание NetWaySP4P

Страница 1: ...tWaySP4P 4 port Fiber Optic Transceiver with Built in Power Supply for Composite Fiber Powered Cable NetWaySP4P2 4 port Fiber Optic Transceiver with Power Limited Outputs for Composite Fiber Powered Cable DOC NETSP Rev 020217 More than just power ...

Страница 2: ...hen using multiple units the sum of the individual name plate ratings should not exceed the supply circuit rating Do not connect to a receptacle controlled by a switch 4 Connect structured cable from ethernet switch NVR network video server to RJ45 jack marked Ethernet 1 4 Fig 2e pg 3 Note All cabling and wire must be UL Listed and or Recognized wire suitable for their application 5 Connect Compos...

Страница 3: ...hnical Specifications Parameter Description Number of Ports Four 4 Gigabit SFP Ports Four 4 ports 10 100 1000Mbps Power Outputs NetWaySP4P Four 4 56VDC non power limited outputs 120W max NetWaySP4P2 Four 4 56VDC power limited outputs 60W each Input power requirements 115VAC 60Hz 3 25A or 230VAC 50 60Hz 2 0A Environmental Conditions Operating Ambient Temperature 120W 40ºC to 50ºC 40ºF to 122ºF Rela...

Страница 4: ...NetWaySP4P2 C31Q MEMBER The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating an...

Отзывы: