Mounting Options:

Rack Mount Installation

1-  Remove and discard factory installed screws from both sides of rack chassis (Fig. 3a).
2-   Install mounting brackets (A) on the left and right side of rack chassis using the four (4) flat head screws (B) (included) (Fig. 3b).
3-  Place unit into desired EIA 19” rack position and secure with mounting screws (not included) (Fig. 3c).

Fig. 5

Left Side

Rubber Pad

B

A

C

Mounting Hardware 

(Included)

:

Two (2) mounting brackets

Six (6) flat head screws
for mounting brackets.

Four (4) rubber pads.

Fig. 3b

Fig. 3a

Fig. 3c

Top

Top

Top

Front
Left

Front
Left

Front Left

Remove

B

A

Fig. 4

Fig. 4b

Fig. 4a

Dotted lines indicate studs 
behind sheetrock.

Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice.

140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: [email protected] | Lifetime Warranty | Made in U.S.A.
IINetWaySP2/4/8 K29Q

MEMBER

The lightning flash with arrowhead symbol within an equilateral triangle

is intended to alert the user to the presence of an insulated DANGEROUS 

VOLTAGE within the product’s enclosure that may be of sufficient magnitude 

to constitute an electric shock.

The exclamation point within an equilateral triangle is intended to alert the user 

to the presence of important operating and maintenance 

(servicing) instructions in the literature accompanying the appliance.

CAUTION: To reduce the risk of electric 

shock do not open enclosure. There are no 

user serviceable parts inside. Refer servicing 

to qualified service personnel.

Wall Mount Installation

1-   Install mounting brackets (A) on the left and right side of rack chassis using
 

four (4) flat head screws (B) (included) (Fig. 4a).

2-  Place unit at desired location and secure with #6 size screws or larger (not included) (Fig. 4b).
 

Caution: It is necessary to make sure mounting screws are securely fastened 

 

to a beam when installing the unit vertically.

Shelf Installation

1-  Position and affix rubber pads (C) (included) at each
 

corner on the bottom of the unit (Fig. 5).

2-  Place unit in desired location.

Содержание NetWaySP2

Страница 1: ...port Fiber Optic Transceiver for Composite Fiber Powered Cable NetWaySP4 4 port Fiber Optic Transceiver for Composite Fiber Powered Cable NetWaySP8 8 port Fiber Optic Transceiver for Composite Fiber Powered Cable DOC NETWAYSP Rev 020217 More than just power ...

Страница 2: ...mperature of 50ºC or the installation of the device must conform to the rated ambient temperature of the power supply to terminals marked In 56VDC Fig 2 pg 3 4 Daisy chaining inputs Connect terminals marked Pass 56VDC to the next input terminals marked In 56VDC Fig 2 pg 3 5 Connect Composite Powered Fiber cable Fiber portion connects to port marked SFP 1 4 copper portion connects to output marked ...

Страница 3: ...vironmental Conditions Operating Ambient Temperature 120W 40ºC to 50ºC 40ºF to 122ºF Relative Humidity 85 5 Storage Temperature 40ºC to 85ºC 40ºF to 185ºF Operating Altitude 304 8 to 2 000m 1 000 to 6 561 679 ft Weights approx NetWaySP4 Product 2 55 lb 1 16kg Shipping 4 7 lb 2 13kg NetWaySP4 Typical Application Fig 1 NetWaySP4 Rear Panel NetWaySP4 Front Panel PoE Camera PoE Camera PoE Camera PoE C...

Страница 4: ...P2 4 8 K29Q MEMBER The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and mai...

Отзывы: