LINQ8ACM(CB) 

- 3 -

•  Eight (8) programmable trigger inputs:
  -  Normally open (NO).
  -  Normally colsed (NC).
  -  Open collector sink inputs.
  -  Wet Input (5VDC - 24VDC) with 10k resistor.
  -  Any combination of the above.
•  Programmable port IDs.
•  Monitor power supply(ies) input for voltage and currect limits (high/low).
•  Input and output current calibration.
•  Programmable timer events.
•  Programmable user levels.
•  Enable or disable alerts by type.
•  Programmable alert reporting delay/

Fire Alarm Disconnect:

•  Fire Alarm disconnect (Inactive, latching or non-latching) is individually selectable for any or all of 
  the eight (8) outputs.
  Fire Alarm disconnect input options: 
    a) Supervised Normally Open [NO] or Normally Closed [NC] dry contact input.
    b) Polarity reversal input from FACP signaling circuit.
•  FACP input WET is rated 5-30VDC 7mA.
•  FACP dry input EOL requires 10K end of line resistor.
•  FACP output relay [NC]: Either Dry 1A/28VDC, 0.6 Power Factor or 10K resistance with [EOL JMP] intact.

Fuse Ratings:

•  Main input fuses rated 15A/32V each.
• 

LINQ8ACM: Output fuses are rated 3A/32V.

• 

LINQ8ACMCB: Output PTCs are rated 2A.

LED Indicators:

• 

Green AC LED: indicates AC trouble condition.

• 

Green BAT LED: indicates battery trouble condition.

• 

Green FACP LED: indicates FACP disconnect is triggered.

• 

Flashing Blue Heartbeat LED: indicates network connection.

• 

Individual OUT1 - OUT8 Red LEDs: indicate outputs are triggered.

• 

Individual Voltage LEDs: indicate 12VDC (Green) or 24VDC (Red).

Environmental:

•  Operating temperature: 0ºC to 49ºC ambient.
•  Humidity: 20 to 93%, non-condensing.

Mechanical:

•  Board Dimensions (W x L x H approximate): 8” x 4.5” x 1.25” (203.2mm x 114.3mm x 31.8mm).
•  Product weight (approx.): 0.7 lb. (0.32 kg).
•  Shipping weight (approx.): 0.95 lb. (0.43 kg).

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code NFPA 70/NFPA 72/ ANSI / Canadian 
Electrical Code / CAN/ULC-S524/ULC-S527/ULC-S537, and with all local codes and authorities having 
jurisdiction. Product is intended for indoor dry use only.
1.  Refer to Sub-Assembly Installation Instruction for mounting Rev. MS020119.
  Carefully review: 
  Terminal/Connector Identification 

(pg. 5) 

Typical Application Diagram 

(pg. 9)

  LED Diagnostics 

(pg. 6) 

Hook-up Diagrams 

(pg. 15-16)

2.  Ensure all output jumpers [OUT1] - [OUT8] are placed in the OFF (center) position.
3.  Connect low voltage DC power supplies to terminals marked [+ PWR1 –], [+ PWR2 –].
 

Note: For VR6 and Tango1B installation please refer to pg. 7, 8.

4.  Set each output [OUT1] - [OUT8] to route power from Power Supply 1 or 2 (Fig. 1)
 

Note:  Measure output voltage before connecting devices. 

        This helps avoiding potential damage.
5.  Turn main power off before connecting devices.

OFF

PWR2

PWR1

Fig. 1

Содержание LINQ8ACM

Страница 1: ...r Controllers Installation and Programming Manual Models include LINQ8ACM Network Access Power Controller Eight 8 Fused Outputs LINQ8ACMCB Network Access Power Controller Eight 8 PTC Outputs Please be...

Страница 2: ...1 12 or 24 VDC from eFlow series power supply Input 2 a 12 or 24 VDC from eFlow series power supply b 5 or 12 VDC from VR6 voltage regulator Dual Input Option 2 24 and 12 VDC from Tango1B PoE Driven P...

Страница 3: ...connect is triggered Flashing Blue Heartbeat LED indicates network connection Individual OUT1 OUT8 Red LEDs indicate outputs are triggered Individual Voltage LEDs indicate 12VDC Green or 24VDC Red Env...

Страница 4: ...arity connect the voltage input trigger wires and the supplied 10K resistor to terminals marked INP1 to INP8 9 Fire Alarm Interface Options program fire alarm interface options via LINQ software A nor...

Страница 5: ...lly Closed NC Open Collector Sink or Wet Input Triggers Tamper Tamper Switch Input AC NC C Connect appropriate signaling notification devices to the terminals to report AC fail BAT NC C Connect approp...

Страница 6: ...Ratings Input Voltage and Source Output Voltage Rating 5VDC from VR6 regulator 5VDC 12V from VR6 regulator 12VDC 12VDC from external power supply 11 7 12VDC 24VDC from external power supply 23 7 24VD...

Страница 7: ...over mounting hole with star pattern 4 Align 8 pin male connector with female receptacle of LINQ8ACM CB then mount 5 Connect 24VDC power supply to terminal marked PWR1 of LINQ8ACM CB Thus Input 1 of L...

Страница 8: ...ACM CB is 24VDC from power supply and Input 2 is determined by Tango1B s settings 12VDC or 12VDC 6 Complete steps 4 10 pgs 3 4 LINQ8ACM LINQ8ACMCB Tango1B Tango1B Fig 4 Ethernet Input 802 3bt PoE up t...

Страница 9: ...PWR1 PWR2 PWR1 PWR2 PWR1 PWR2 PWR1 OUT1 OUT7 OUT2 OUT3 OUT4 OUT5 OUT6 OUT8 NC C NO BAT AC Tamper NC C NO INP1 INP2 INP3 INP4 INP5 INP6 INP7 INP8 A C B A T F A C P B e a t O u t1 O u t2 O u t3 O u t4...

Страница 10: ...e effect after the server is rebooted Click OK DHCP a After selecting DHCP in the IP Address Method field click the button labeled Submit Network Settings A dialog box will display New network setting...

Страница 11: ...stamp the system log and email alerts 1 Click on the Status tab to access the status page 2 Click the time and date in the upper left a dialog box will open 3 Click on SYNC DATE AND TIME A Hardware Se...

Страница 12: ...either of these limits are exceeded an alert message and or email notification will be generated 4 Click on the button labeled Submit to save the settings Output Current Calibration During the initial...

Страница 13: ...remote access and monitoring The default inbound port setting is 80 HTTP is not encrypted and unsecure Even though HTTP can be used for remote access it is recommended primarily for use with LAN conne...

Страница 14: ...2 Locate the new certificate file 3 Upload the certificate file 4 Under Key upload click on Select Key File 5 Locate the new certificate file 6 Upload the Key file 7 Click on the button labeled Submit...

Страница 15: ...he EOL position Latching Single Reset COM F R GND GND C F R EOL RST NC FACP COM F R GND GND C F R EOL RST NC FACP Jumper Jumper COM F R GND GND C F R EOL RST NC FACP COM F R GND GND C F R EOL RST NC F...

Страница 16: ...Jumper EOL Fig 10 Polarity reversal input from FACP signaling circuit output polarity is referenced in alarm condition Latching COM F R GND GND C F R EOL RST NC FACP EOL N O Switch Hook Up Diagrams CO...

Отзывы: