Altronix HubWayLD8DS Скачать руководство пользователя страница 3

 

HubWayLD8DS 

- 3 -

   Installation  Instructions:

1.  Set the input voltage selector switch located on the left side of the HubWayLD8DS unit for 115VAC or 
 

230VAC operation (Fig. 1k, pg. 4).

2.  Attach mounting brackets to the HubWayLD unit for rack or wall mount installation (Figs. 6-7, pg. 8)
 

Affix rubber pads to the HubWayLD unit for shelf installation (Fig. 8, pg. 8).

3.  Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at 
 

least 3” from any video monitors).

4.  Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 5, pg. 7).
5.  Plug the grounded AC line cord (included) into the IEC 320 connector of the HubWayLD8DS unit 
 

(Fig. 1f, pg. 4). Insert the plug end of the line cord into a grounded AC receptacle.

6.  Set voltage output selector switch of each camera channel for 24VAC or 28VAC (Fig. 1a, pg. 4).
7.  Connect the BNC video outputs for HubWayLD8DS Channels 1-8 to the corresponding video inputs on 
 

the head end equipment (DVR) (Fig. 1d, pg. 4).

8.  Connect the RS422/RS485 output of the head end equipment (DVR) to the data input terminal block of
 

the HubWayLD8DS unit (polarity must be observed) (Fig. 1c, pg. 4)

9.  Connect Video Balun/Combiner at camera 1 to the HubWayLD8DS unit utilizing CAT-5 or higher 
 

structured cable. Plug the RJ45 connector at one end of the structured cable into the RJ45 jack marked 

 

[Channel 1] of the HubWayLD8DS (Fig. 1h, pg. 4). Plug the RJ45 connector at the opposite end of the 

 

structured cable into the RJ45 jack of the Video Balun/Combiner located at camera 1.

 

•  For 24VAC cameras use Altronix model HubWayAv/HubWayAv2 Video Balun/Combiner

  (Figs. 2a, 2b, 2e, pg. 5).
 

•  For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 2c, 2d, pg. 5).

 

•  For non-isolated 12VDC cameras use Altronix model HubWayDvi Video Balun/Combiner 

  (Figs. 2c, 2d, pg. 5). Repeat steps 6-9 for each additional camera (Channels 2-8).
 

Note: When a particular camera exceeds the maximum distance for power transmi  ssion, a local external 

 

power source is required. Optionally, an Altronix HubSat4D Passive UTP Transceiver Hub with Integral 

 

Camera Power unit may be utilized (Fig. 4a, pg. 6). The combined total cable distance must not exceed 

 

3000 ft. for video transmission between the HubWayLD8DS and each camera routed through the HubSat4D.

10.  Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5, pg. 7) and 
 

measure the output voltage at the power output of each Video Balun/Combiner (Figs. 2b, 2d, pg. 5) before 

 

powering each camera to ensure proper operation and avoid possible damage.

 

•  HubWayAv/HubWayAv2 - Terminals marked [AC POWER] (Figs. 2a, 2b, 2e, pg. 5).

 

•  HubWayDv/HubWayDvi - Terminals marked [– 12VDC +] (Figs. 2c, 2d, pg. 5).

11.  Set illuminated master power disconnect circuit breaker to the (OFF) position to make the final connections
 

(Fig. 5, pg. 7).

12.  Connect the power outputs of the HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/
 

Combiners to the power inputs of the cameras (Figs. 2a-2e, pg. 5). Polarity must be observed.

13.  Connect the terminals marked [+ DATA –] of the HubWayAv, HubWayAv2, HubWayDv or HubWayDvi 
 

Video Balun/Combiners to the data terminals of the cameras for PTZ control (Figs. 2a-2e, pg. 5). Polarity 

 

must be observedWhen using fixed cameras disregard this step.

14.  Connect the BNC connector of the HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/
 

Combiners to the BNC video outputs of the cameras (Figs. 2a-2e, pg. 5).

15.  Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) 
 position 

(Fig. 5, pg. 7). 

16.  The power LEDs (Red) located on the front of the HubWayLD8DS will illuminate when AC power 
 

is present (Fig. 1c, pg. 4).

17.  AC LEDs (Green) of the HubWayAv or DC LEDs (Red) of the HubWayDv/HubWayDvi Video Balun/
 

Combiners will illuminate indicating power is present at the cameras (Fig. 2b, 2d, pg. 5). 

18.  The video signal indicator LEDs (Red) located on the rear of the HubWayLD8DS will illuminate when 
 

video signal is present (Fig. 1i, pg. 4). If any of these LEDs are not illuminated, no video signal is present 

 

for that corresponding channel.

 

Note: If any of these LEDs are not illuminated either a voltage output selector switch is in the OFF 

 

position or the PTC is tripped for that channel.

 

To reset the PTC:

 

1.  Set the voltage output selector switch for that corresponding channel to the OFF position. 

 

 

Switch must remain in the OFF position for approximately 2 minutes in order for the PTC to reset.

 

2.  Eliminate the trouble condition (short circuit or overload).

 

3.  Set the voltage output selector switch for 24VAC or 28VAC (Fig. 1a, pg. 4).

19.  Optimize the picture quality for all camera channels by adjusting the corresponding potentiometers 
 

marked [Picture] (Fig. 1g, pg. 4).

20.  Set gain for all camera channels by adjusting the corresponding potentiometers marked [Gain] 
 

(Fig. 1h, pg. 4).

Содержание HubWayLD8DS

Страница 1: ...ctive UTP Transceiver Hub with Integral Camera Power HubWayLD82DS UL Listed eight 8 Channel Active UTP Transceiver Hub with Integral Camera Power Includes eight 8 UL Listed Accessory HubWayAv Video Balun Combiners HubWayLD83DS UL Listed eight 8 Channel Active UTP Transceiver Hub with Integral Camera Power Includes eight 8 UL Listed Accessory HubWayDv Video Balun Combiners Z1409 ...

Страница 2: ...HubWayLD8DS with eight 8 UL Listed Accessory HubWayDv Video Balun Combiners for 12VDC Cameras WARNING To reduce the risk of fire or electric shock do not expose the unit to rain or moisture This installation should be made by qualified service personnel and should conform to all local codes Agency Listings UL Listed for Commercial CCTV Equipment UL 2044 Input 115VAC 60Hz 1 5A or 230VAC 50 60Hz 1A ...

Страница 3: ...uminated master power disconnect circuit breaker to the RESET ON position Fig 5 pg 7 and measure the output voltage at the power output of each Video Balun Combiner Figs 2b 2d pg 5 before powering each camera to ensure proper operation and avoid possible damage HubWayAv HubWayAv2 Terminals marked AC POWER Figs 2a 2b 2e pg 5 HubWayDv HubWayDvi Terminals marked 12VDC Figs 2c 2d pg 5 11 Set illuminat...

Страница 4: ...put voltage switches Selects 24VAC 28VAC OFF for each output 1g Channels 1 4 Channels 5 8 Links HubSat units enabling video transmission of up to four 4 cameras over a single CAT 5 structured cable 1f IEC 320 Connector 115VAC 230VAC 50 60Hz grounded line cord included Fig 1 1c Data Removable terminal blocks for RS422 RS485 input from head end equipment DVR for PTZ control Data input from Head End ...

Страница 5: ...RJ45 Jack RJ45 Jack To BNC Connector of Camera To BNC Connector of Camera Structured Cable from HubWay8CD or HubWay16CD Structured Cable from HubWay8CD or HubWay16CD VIDEO BALUN COMBINER HubWayDv CAT5 DATA 12VDC Wire Connectors Also Available as HubWayDvi Video Balun Combiner for non isolated 12VDC cameras Fig 2 Fig 2a Fig 2c Fig 2b Fig 2d Fig 2e HubWayAV2 Video from Camera Data to Camera Power to...

Страница 6: ...o Balun Combiner Video Data PTZ Camera PTZ Camera PTZ Camera Power Video Data Power HubWayAv Video Balun Combiner CAT 5 HubWayAv Video Balun Combiner CAT 5 Max video 3000 ft Video Power HubWayDv Dvi Video Balun Combiner CAT 5 Video Data Outdoor PTZ Camera CAT 5 HubWayAv or HubWayDv Dvi Video Balun Combiner IEC 320 Connector 115VAC 60 Hz AC POWER 8 7 6 5 4 3 2 1 24VAC OFF 28VAC DATA 1 2 3 4 5 6 7 8...

Страница 7: ... To reduce the risk of electric shock do not open enclosure There are no user serviceable parts inside Refer servicing to qualified service personnel 1U EIA 19 Rack Mount Chassis Dimensions H x W x D approximate 1 625 x 19 125 x 8 5 41 3mm x 486mm x 216mm AC POWER PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN 8 7 6 5 4 3 2 1 24VAC OFF 28VAC...

Страница 8: ... 6c A B Fig 6b Fig 6a Fig 6 Fig 6c Top Top Top Front Left Front Left Front Left Remove Wall Mount Installation 1 Install mounting brackets A on the left and right side of rack chassis using four 4 flat head screws B included Fig 7a 2 Place unit at desired location and secure with 6 size screws or larger not included Fig 7b Caution It is necessary to make sure mounting screws are securely fastened ...

Отзывы: