background image

HubWayLD Active Unit

- 3 -

3. Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least

3” from any video monitors).

4. Set illuminated master power disconnect circuit breaker to the (OFF) position 

(Fig. 5, pg. 7)

.

5. Plug the grounded AC line cord (included) into the IEC 320 connector of the HubWayLD8D/HubWayLD16D

unit 

(Fig. 1j, pg. 4)

. Insert the plug end of the line cord into a grounded AC receptacle.

6. Set voltage output selector switch of each camera channel for 24VAC or 28VAC 

(Fig. 1d, pg. 4)

.

7. Connect the BNC video outputs for HubWayLD8D/LD16D Channels 1 - 8 (Channels 1-16) to the

corresponding video inputs on the head end equipment (DVR) 

(Fig. 1f, pg. 4)

.

8. Connect the RS422/RS485 output of the head end equipment (DVR) to the one (1) or both data input terminal 

blocks of the HubWayLD8D or HubWayLD16D unit (polarity must be observed) 

(Fig. 1e, pg. 4)

Note:

The Data input terminals of the HubWayLD8D or HubWayLD16D must be wired in parallel for proper

operation. When using fixed cameras disregard this step.

9. Connect Video Balun/Combiner at camera 1 to the HubWayLD8D or HubWayLD16D unit utilizing CAT-5 or higher 

structured cable. Plug the RJ45 connector at one end of the structured cable into the RJ45 jack marked [Channel 1] 
of the HubWayLD8D/LD16D 

(Fig. 1a, pg. 4)

. Plug the RJ45 connector at the opposite end of the structured 

cable into the RJ45 jack of the Video Balun/Combiner located at camera 1.
• For 24VAC cameras use Altronix model HubWayAv Video Balun/Combiner 

(Figs. 2a, 2b, pg. 5)

.

• For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner 

(Figs. 2c, 2d, pg. 5)

.

• For non-isolated 12VDC cameras use Altronix model HubWayDvi Video Balun/Combiner 

(Figs. 2c, 2d, pg. 5)

.

Repeat steps 6-9 for each additional camera (Channels 2-8 or Channels 2-16).

Note:

When a particular camera exceeds the maximum distance for power transmission, a local 

external power source is required. Optionally, an Altronix HubSat4D Passive UTP Transceiver Hub with Integral 
Camera Power may be utilized 

(Fig. 4a, pg. 6)

. The combined total cable distance must not exceed 3000 ft. for 

video transmission between the HubWayLD8D/LD16D and each camera routed through the HubSat4D.

10. Set illuminated master power disconnect circuit breaker to the RESET (ON) position 

(Fig. 5, pg. 7) 

and measure the

output voltage at the power output of each Video Balun/Combiner 

(Figs. 2b, 2d, pg. 5)

before powering each camera 

to insure proper operation and avoid possible damage.
• HubWayAv - Terminals marked [AC POWER] 

(Figs. 2a, 2b, pg. 5)

.

• HubWayDv/HubWayDvi - Terminals marked [– 12VDC +] 

(Figs. 2c, 2d, pg. 5)

.

11. Set illuminated master power disconnect circuit breaker to the (OFF) position to make the final connections 

(Fig. 5, pg. 7)

.

12. Connect the power outputs of the HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners to the 

power inputs of the cameras 

(Figs. 2a-2d, pg. 5). 

Polarity must be observed.

13. Connect the terminals marked [+ DATA -- ] of the HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners 

to the data terminals of the cameras for PTZ control 

(Figs. 2a-2d, pg. 5)

. Polarity must be observed

.

When using fixed cameras disregard this step.

14. Connect the BNC connectors of the HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners to the 

BNC video outputs of the cameras 

(Figs. 2a-2d, pg. 5)

.

15. Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) position

(Fig. 5, pg. 7).

16. The power LEDs (Red) located on the front of the HubWayLD8CD/LD16CD will illuminate when AC power 

is present 

(Fig. 1c, pg. 4).

Note:

If any of these LEDs are not illuminated either a voltage output selector switch is in the OFF position or the 

PTC is tripped for that channel.
To reset the PTC:
1. Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must remain

in the OFF position for approximately 2 minutes in order for the PTC to reset.

2. Eliminate the trouble condition (short circuit or overload).
3. Set the voltage output selector switch for 24VAC or 28VAC 

(Fig. 1d, pg. 4)

.

17. AC LEDs (Green) of the HubWayAv or DC LEDs (Red) of the HubWayDv/HubWayDvi Video Balun/Combiners 

will illuminate indicating power is present at the cameras 

(Fig. 2b, 2d, pg. 5).

18. The video signal indicator LEDs (Red) located on the rear of the HubWayLD8CD/LD16CD will illuminate when 

video signal is present 

(Fig. 1i, pg. 4).

If any of these LEDs are not illuminated, no video signal is present for 

that corresponding channel.

19. Optimize the picture quality for all camera channels by adjusting the corresponding potentiometers 

marked [Picture] 

(Fig. 1g, pg. 4).

20. Set gain for all camera channels adjusting the corresponding potentiometers marked [Gain] 

(Fig. 1h, pg. 4).

Содержание HubWayLD8D

Страница 1: ...ansceiver Hub with Integral Camera Power Transceiver Hub with Integral Camera Power Includes eight 8 UL Listed Accessory Includes sixteen 16 UL Listed Accessory HubWayAv Video Balun Combiners HubWayAv Video Balun Combiners HubWayLD83D HubWayLD163D UL Listed eight 8 Channel Active UTP UL Listed sixteen 16 Channel Active UTP Transceiver Hub with Integral Camera Power Transceiver Hub with Integral Ca...

Страница 2: ...ssory HubWayAv Video Balun Combiners for 24VAC Cameras HubWayLD83D HubWayLD8D with eight 8 UL Listed Accessory HubWayDv Video Balun Combiners for 12VDC Cameras HubWayLD162D HubWayLD16D with sixteen 16 UL Listed Accessory HubWayAv Video Balun Combiners for 24VAC Cameras HubWayLD163D HubWayLD16D with sixteen 16 UL Listed Accessory HubWayDv Video Balun Combiners for 12VDC Cameras Agency Listings UL L...

Страница 3: ...nnect circuit breaker to the RESET ON position Fig 5 pg 7 and measure the output voltage at the power output of each Video Balun Combiner Figs 2b 2d pg 5 before powering each camera to insure proper operation and avoid possible damage HubWayAv Terminals marked AC POWER Figs 2a 2b pg 5 HubWayDv HubWayDvi Terminals marked 12VDC Figs 2c 2d pg 5 11 Set illuminated master power disconnect circuit break...

Страница 4: ... transmission to PTZ s 1f BNC Connector Video outputs to head end equipment DVR 1d Output voltage switches Selects 24VAC 28VAC OFF for each output 1b Channels 1 4 Channels 5 8 Channels 9 12 Channels 13 16 CAT 5 or higher structured cable from optional HubSat4D enables video transmission from up to four 4 cameras 1i LED s 1 16 Video signal indicators 1j IEC 320 Connector 115VAC 60Hz 230VAC 50 60Hz ...

Страница 5: ...ER HubWayDv CAT5 DATA 12VDC Wire Connectors Also Available as HubWayDvi Video Balun Combiner for non isolated 12VDC cameras Fig 2 Fig 2c Fig 2a Fig 2b Fig 2d HubWayAv passes AC voltage from pins 4 5 7 8 to terminals marked AC Power Fig 3 pg 5 HubWayDv HubWayDvi converts AC voltage to DC voltage from pins 4 5 7 8 to terminals marked 12VDC Fig 3 pg 5 HubWayAv HubWayDv and HubWayDvi Video Balun Combi...

Страница 6: ...o Balun Combiner HubWayAv Video Balun Combiner Fixed Camera Fixed Camera Max video 3000 ft PTZ Camera Video Power HubWayDv Dvi Video Balun Combiner CAT 5 24VAC 28VAC Camera Power Provided by HubSat4D Video Data Power Outdoor NEMA Rated Power Supply Outdoor PTZ Camera 115VAC Input 50 60Hz HubWayAv or HubWayDv Dvi Video Balun Combiner Monitor Rear Front 1 2 3 4 CH 1 4 CH 5 8 28VAC OFF 24VAC DATA 1 8...

Страница 7: ...ed master power disconnect circuit breaker OFF position Circuit breaker tripped Switch not illuminated RESET ON position Switch illuminated The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the products enclosure that may be of sufficient magnitude to constitute an electric shock The excl...

Страница 8: ...am when installing the unit vertically Rack Mount Installation 1 Remove and discard factory installed screws from both sides of rack chassis Fig 6a 2 Install mounting brackets A on the left and right side of rack chassis using the four 4 flat head screws B included Fig 6b 3 Place unit into desired EIA 19 rack position and secure with mounting screws not included Fig 6c Fig 8 Fig 7 Shelf Installati...

Отзывы: