Altronix HubSat42WPiV Скачать руководство пользователя страница 8

 

- 8 -  

HubSat4WPiV

The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient
magnitude to constitute an electric shock.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important 
operating and maintenance (servicing) instructions in the literature accompanying the appliance.

CAUTION: To reduce the risk of electric shock do not open enclosure. There
are no user serviceable parts inside. Refer servicing to qualified service personnel.

Wall Mount Installation

1.  Place unit at the desired location and secure with mounting screws (not included) (Fig. 8 and Fig. 8a, pg. 8).

Fig. 8

Fig. 8a

Содержание HubSat42WPiV

Страница 1: ...ssive UTP Transceiver Hub with Integral Isolated Camera Power HubSat42WPiV Four 4 Channel Outdoor Passive UTP Transceiver includes four 4 HubWayAv Video Balun Combiners HubSat43WPiV Four 4 Channel Outdoor Passive UTP Transceiver includes four 4 HubWayDv Video Balun Combiners Rev 060210 More than just power TM Video Data Power ...

Страница 2: ...Cameras WARNING This installation should be made by qualified service personnel Unit should be installed in accordance with the National Electrical Codes and all local codes For continued protection against risk of fire replace all fuses only with the same type and rating Installation Instructions HubSat4WPiV Outdoor Passive UTP Transceiver Hub with Integral Isolated Camera Power 1 Remove back pla...

Страница 3: ...put selector switch for either 24VAC or 28VAC Fig 2d pg 4 HubSat4WPiV for use as a Remote Accessory Module with HubWay HubWayLD HubWayLDH UTP Transceiver Hubs After completing steps 1 4 of Installation Instructions HubSat4WPiV Outdoor Passive UTP Transceiver Hub with Integral Camera Power proceed with the following 1 For fixed cameras run a single CAT 5 cable between HubSat4WPiV and HubWay HubWayL...

Страница 4: ... output selector switch for either 24VAC or 28VAC Fig 2d pg 4 Alternate 24VAC fixed camera hookup Fig 7a pg 7 After completing steps 1 5 of Installation Instructions Remote Accessory Module for use with HubWay HubWayLD or HubWayLDH UTP Transceiver Hubs proceed with the following 1 Set illuminated master power disconnect circuit breaker to the OFF position Fig 5a pg 6 2 Connect one end of the coaxi...

Страница 5: ...or head end equipment DVR 2i Channels 1 4 CAT 5 or higher structured cable to cameras 2a 2i 2b 2c 2d 2e 2f 2g 2h 2c Fig 3e HubWayAv2 Video from Camera Data to Camera Power to Camera Cat5 back to HubWay or HubSat VIDEO BALUN COMBINER CAT5 DATA POWER AC VIDEO HubWayAv VIDEO AC Power to Camera Data to Camera Data to Camera Green Power LED 12VDC Power to Camera Red Power LED Wire Connectors RJ45 Jack ...

Страница 6: ...20VAC Input 50 60 Hz Red Lead Black Lead 6 HubSat4WPiV Fig 5a Illuminated master power disconnect circuit breaker OFF position or Circuit breaker tripped Switch not illuminated RESET ON position Switch illuminated Fig 5 Fig 5b 1 White Orange VIDEO 2 Orange VIDEO 3 White Green DATA 4 Blue AC 1 5 White Blue AC 2 6 Green DATA 7 White Brown AC 2 8 Brown AC 1 CAT 5 Structured Cable Wiring Color Codes a...

Страница 7: ...2 3 4 CH 1 4 CH 5 8 28VAC OFF 24VAC DATA 1 8 5 6 7 8 PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE AC POWER GAIN 8 7 6 5 4 3 2 1 Video Coax Power Video Coax Power 24VAC Fixed Camera Video Coax Power 24VAC 28VAC Camera Power Provided by HubSat4WPiV 220VAC Input 60Hz 24VAC Fixed Camera Video Power HubWayDv Dvi Video Balun Combiner CAT 5 CAT 5 CAT ...

Страница 8: ...oint within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance CAUTION To reduce the risk of electric shock do not open enclosure There are no user serviceable parts inside Refer servicing to qualified service personnel Wall Mount Installation 1 Place unit at the desired lo...

Страница 9: ...crew with flat head screwdriver or 5 16 hex socket driver Fig 9a pg 9 and Fig 9b pg 9 3 Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket tightening bolts with a 7 16 hex socket Fig 9c pg 9 4 Thread the second wormgear quick release strap through the slots on the back of the bottom mounting bracket Fig 9 pg 9 5 Mount enclosure on...

Страница 10: ... 10 HubSat4WPiV Notes ...

Страница 11: ...HubSat4WPiV 11 Notes ...

Страница 12: ...7 9056 website www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIHubSat4WPiV D01P MOUNTING PANEL GALVANIZED CARBON STEEL SHEET 13 330mm 4 05 103mm 6 152 4mm 8 203 2mm 4 21 107mm 12 305mm 6 7 170mm 9 84 250mm 0 08 2mm 14 355 6mm Enclosure Dimensions H x W x D approximate 12 x 8 x 6 304 8mm x 203 2mm x 152 4mm MEMBER ...

Отзывы: