7.  Plug the RJ45 connector at one end of the CAT-5 or higher structured cable into the RJ45 jack marked 

 

[PVD1] on HubSat4Di 

(Fig. 1i, pg. 6)

. Plug the RJ45 connector at the opposite end of the CAT-5 or 

 

higher structured cable into the RJ45 jack of the Video Balun/Combiner to be installed at camera 1.

 

•  For 24VAC cameras use Altronix model HubWayAv/HubWayAv2 Video Balun/Combiner 

  

(Figs. 2a, 2b, 2e. pg. 7)

.

 

•  For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner 

(Figs. 2c, 2d, pg. 7)

.

 

The total cable distance must not exceed 750 ft. for video transmission between the HubSat4Di and each 

 

camera. Repeat this step for all other camera channels [PVD2-4].

8.  Set illuminated master power disconnect circuit breaker to the RESET (ON) position 

(Fig. 4a, pg. 8). 

 

Power LEDs (Green) of the HubSat will illuminate when AC power is present 

(Fig. 1e, pg. 6) 

and 

 

HubWayAv and HubWayDv Video Balun/Combiner LEDs will illuminate indicating power is present 

 

(Fig. 2b, 2d, pg. 7).

9.  Measure the output voltage at each Video Balun/Combiner 

(Figs. 2b, 2d, pg. 7)

 before making connections 

 

to each camera to ensure proper operation and avoid possible damage.

10.  Set illuminated master power disconnect circuit breaker to the (OFF) position 

(Fig. 4a, pg. 8)

.

11.  Connect power outputs of HubWayAv, HubWayAv2 or HubWayDv Video Balun/Combiners to power 

 

inputs of cameras 

(Figs. 2a-2e, pg. 7). 

Polarity must be observed.

 

•  HubWayAv/HubWayAv2 - Terminals marked [AC POWER] 

(Figs. 2a, 2b, 2e, pg. 7)

.

 

•  HubWayDv - Terminals marked [– 12VDC +] 

(Figs. 2c, 2d, pg. 7)

.

12.  Connect the terminals marked [+ DATA –] of HubWayAv, HubWayAv2v or HubWayDv Video Balun/

 

Combiners to the data input terminals of cameras for PTZ control 

(Figs. 2b-2d, pg. 7)

. Polarity must be 

 observed

When using fixed cameras disregard this step.

13.  Connect the BNC connector of HubWayAv, HubWayAv2 or HubWayDv Video Balun/Combiners to the 

 

BNC video outputs of cameras 

(Figs. 2b-2d, pg. 7)

.

14.  Set illuminated master power disconnect circuit breaker to the RESET (ON) position 

(Fig. 4a, pg. 8).

15.  The power LEDs (Green) of the HubSat4Di will illuminate when AC power is present 

(Fig. 1e, pg. 6).

  

 

Note:

 If any of the power LEDs are not illuminated the cause may be due to the following:

 

a.  AC mains fail.

 

b.  Illuminated master power disconnect circuit breaker is tripped.

 

c.  An individual power output voltage switch is set to the OFF position 

(Fig. 1d, pg. 6)

.

 

d.  A PTC is tripped due to a short circuit or overload condition for one or more channels/power outputs.

 

 

To reset the PTC:

 

 

1. Set the voltage output selector switch for that corresponding channel to the OFF position. 

 

 

  Switch must remain in the OFF position for approximately 2 minutes in order for the PTC to reset 

    

(Fig. 1d, pg. 6)

.

 

 

2. Eliminate the trouble condition (short circuit or overload).

 

 

3. Set the voltage output selector switch for either 24VAC or 28VAC 

(Fig. 1d, pg. 6)

.

HubSat4Di for use as a Remote Accessory Module with HubWay/HubWayLD/HubWayLDH UTP 

Transceiver Hubs.

After completing steps 1-4 of Installation Instructions for HubSat4Di Passive UTP Transceiver Hub with Integral 

Isolated Camera Power proceed with the following.

1.  For fixed cameras, run a single CAT-5 cable between HubSat4Di and HubWay, HubWayLD or 

 

HubWayLDH to allow video transmission of up to four (4) cameras. For PTZs, run two (2) CAT-5 cables 

 

between HubSat4Di and HubWay, HubWayLD or HubWayLDH 

(Fig. 6, pg. 9)

.

 

a.  Connect one (1) of the CAT-5 cables to the RJ45 jack marked [Video 1-4] on HubSat4Di. Connect the

 

 

opposite end of this CAT-5 cable into the RJ45 jack marked [CH 1-4] of HubWay, HubWayLD or

 

 

HubWayLDH unit 

(Fig. 6, pg. 9)

.

 

b.  For data (PTZ), connect the second CAT-5 cable to the RJ45 jack marked [Data 1-4] on HubSat4Di. 

 

 

Connect the opposite end of this CAT-5 cable into any unused RJ45 jack marked [1-16] of HubWay, 

 

 

HubWayLD or HubWayLDH unit 

(Fig. 6, pg. 9)

.

 

Note:

 Data inputs of HubWay, HubWayLD or HubWayLDH units must be wired in parallel for proper 

 

operation. When using fixed cameras disregard this step.

Содержание HubSat42Di

Страница 1: ..._ Phone ___________________ Installation Guide Video Data Power HubSat4Di Series Passive UTP Transceiver Hub with Integral Isolated Camera Power Models Include HubSat4Di Four 4 Camera Channels HubSat42Di HubSat4Di with four 4 HubWayAv Video Balun Combiners for 24VAC Cameras HubSat43Di HubSat4Di with four 4 HubWayDv Video Balun Combiners for 12VDC Cameras Rev 090209 ...

Страница 2: ... with HubWay HubWayLD HubWayLDH UTP Transceiver Hubs pg 4 Alternate 24VAC Fixed Camera Hookup pg 5 HubSat4Di Circuit Board pg 6 HubWayAv HubWayAv2 HubWayDv Video Balun Combiners pg 7 CAT 5 Structured Cable Wiring Color Codes and PIN Configurations pg 7 Typical Application Drawings HubSat4Di as a Passive UTP Transceiver Hub with Integral Camera Power pg 9 HubSat4Di as a Remote Accessory Module with...

Страница 3: ...ut of the head end equipment DVR Fig 1f pg 6 When using fixed cameras disregard this step HubSat42Di HubSat4Di w four 4 HubWayAv Video Balun Combiners for 24VAC Cameras HubSat43Di HubSat4Di w four 4 HubWayDv Video Balun Combiners for 12VDC Cameras Input 115VAC 50 60Hz 1 25A Video Four 4 channels of quality video over twisted pair up to a distance of 750 ft per channel Four 4 75 Ohm video outputs D...

Страница 4: ...outputs of cameras Figs 2b 2d pg 7 14 Set illuminated master power disconnect circuit breaker to the RESET ON position Fig 4a pg 8 15 The power LEDs Green of the HubSat4Di will illuminate when AC power is present Fig 1e pg 6 Note If any of the power LEDs are not illuminated the cause may be due to the following a AC mains fail b Illuminated master power disconnect circuit breaker is tripped c An i...

Страница 5: ...ct the BNC connector of HubWayAv HubWayAv2 or HubWayDv Video Balun Combiners to the BNC video outputs of cameras Figs 2b 2e pg 7 9 Set illuminated master power disconnect circuit breaker to the RESET ON position Fig 4a pg 8 10 The power LEDs Green of the HubSat4Di will illuminate when AC power is present Fig 1e pg 6 Note If any of the power LEDs are not illuminated the cause may be due to the foll...

Страница 6: ...CAT 5 or higher structured cable out to HubWay HubWayLD or HubWayLDH enables transmission of up to four 4 video signals Pin out configuration Fig 3 pg 7 1h Data CAT 5 or higher structured cable to data port on HubWay HubWayLD or HubWayLDH or head end equipment DVR 1i Channels 1 4 CAT 5 or higher structured cable to cameras Pin out configuration Fig 3 pg 7 Fig 1 HubSat4Di Circuit Board PVD1 VIDEO1 ...

Страница 7: ...f Camera To BNC Connector of Camera Structured Cable from HubWay8CD or HubWay16CD Structured Cable from HubWay8CD or HubWay16CD VIDEO BALUN COMBINER HubWayDv CAT5 DATA 12VDC Wire Connectors Also Available as HubWayDvi Video Balun Combiner for non isolated 12VDC cameras Fig 2 Fig 2a Fig 2c Fig 2b Fig 2d Fig 2e HubWayAV2 Video from Camera Data to Camera Power to Camera Cat5 back to HubWay or HubSat ...

Страница 8: ...VAC 28VAC 24VAC 28VAC 24VAC OFF OFF OFF OFF AUX1 AUX2 AUX3 AUX4 non power limited non power limited non power limited Green Lead ground Input 115VAC 60Hz ON Fig 4a Illuminated master power disconnect circuit breaker OFF position circuit breaker tripped Switch not illuminated RESET ON position Switch illuminated Fig 4 ...

Страница 9: ...Camera Data Video Head End Equipment DVR RS485 Monitor Rear Front 1 2 3 4 CH 1 4 CH 5 8 28VAC OFF 24VAC DATA 1 8 5 6 7 8 PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE AC POWER GAIN 8 7 6 5 4 3 2 1 Video Coax Power Video Coax Power 24VAC Fixed Camera Video Coax Power 24VAC 28VAC Camera Power Provided by HubSat4i 115VAC Input 50 60Hz 24VAC Fixed C...

Страница 10: ... 10 HubSat4Di Installation Guide Notes ...

Страница 11: ...HubSat4Di Installation Guide 11 Notes ...

Страница 12: ...mm 1 25 4mm 1 25 4mm 1 25 31 75mm 1 25 31 75mm 1 25 4mm 1 25 4mm 5 25 133 35mm 6 05 153 7mm 3 5 88 9mm The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral t...