Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local
codes and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the
application.
eBridge1PCTX, eBridge1ST, and eBridge4PCRM are not intended to be connected to outside plant leads and
should be installed indoors within the protected premises. eBridge1PCTX, eBridge1ST, and eBridge4PCRM are
intended for indoor use only.
1.
eBridge4PCRM installation:
a. Affix rubber pads to eBridge4PCRM for shelf installation (Fig. 5, pg. 8).
Unit should be mounted in proximity to ethernet switch/network, NVR or video server.
b.
Connect structured cable from ethernet midspan or endspan device to RJ45 jack marked [10/100BaseT]
(Fig. 2, pg. 4).
c. Connect Coax cable to BNC connector marked [Coax] (Fig. 1, pg. 3).
2.
eBridge1PCTX installation:
a. Secure unit to desired mounting surface with a proper fastening device utilizing the case’s mounting hole.
Unit should be mounted in proximity of camera/device.
b. Connect structured cable from IP camera/device to RJ45 jack marked [10/100BaseT] (Fig. 2, pg. 4).
c. Connect Coax cable to BNC connector marked [Coax] (Fig. 2, pg. 4).
3.
eBridge1ST installation:
a. Secure unit to the desired mounting surface with a proper fastening device utilizing the case’s mounting
hole
(Fig. 3, pg. 4). Unit should be mounted in proximity of camera/device.
b. Connect structured cable from IP camera/device to RJ45 jack marked [PoE Out] (Fig. 3, pg. 4).
c. Connect Coax cable from eBridge4PCRM to BNC tether cable marked [Coax] (Fig. 3, pg. 4).
Note: eBridge4PCRM is designed to accommodate Megapixel, HD720, HD1080 and VGA (SD) cameras. It is
important to note that some high resolution and high frame rate cameras may demand faster headend processing
ability, such as a PC graphics card to present a quality image. If the headend processing equipment is insufficient
in speed, the image may show pixelation and latency. It is advisable to pre-test system if unsure. Alternatively,
frame rate and resolution may be reduced to accommodate system equipment.
Fig. 1
eBridge4PCRM
10/100
Base-T
Structured
Cable from
midspan/endspan
Data In
Coax
Cable from
eBridge1PCT or
eBridge1PCTX
Front Panel
Back Panel
Содержание eBridge4PCRM
Страница 7: ...eBridge4PCRM 7 Notes ...