eBridge100RM Installation Guide
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes
and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application.
eBridge100TM/eBridge100ST and eBridge100RM are not intended to be connected to outside plant leads and
should be installed indoors within the protected premises. eBridge100TM, eBridge100ST, and eBridge100RM are
intended for indoor use only.
Note:
The eBridge100RM can be paired with either eBridge100TM or eBridge100ST.
1.
eBridge100RM installation:
a. Secure unit to desired mounting surface with a proper fastening device utilizing the unit’s mounting hole
(Fig. 2a, pg. 3)
. Unit should be mounted in proximity to ethernet switch/network, NVR or video server.
Note:
When installing more than one (1) eBridge100RM, please allow at least 1” (25mm) distance
between the receivers.
b.
Connect structured cable from Ethernet midspan or endspan device to RJ45 jack marked [PoE Input]
(Fig. 2, pg. 3)
.
c.
When connecting to the eBridge100 transceiver:
Coax:
Connect Coax cable to BNC connector marked [Coax]
(Fig. 2, pg. 3)
.
CAT5 or higher:
Connect CAT5 or higher to connector marked [RJ45 OUT] (eBridge100TM only)
(Fig. 2, pg. 3)
.
2.
eBridge100TM installation:
a. Secure unit to desired mounting surface with a proper fastening device utilizing the case’s mounting hole
(Fig. 2a, pg. 3)
. Unit should be mounted in proximity of camera/device.
b. Connect structured cable from IP camera/device to RJ45 jack marked [PoE Out]
(Fig. 2, pg. 3)
.
c.
Coax:
Connect Coax cable to BNC connector marked [Coax]
(Fig. 2, pg. 3)
.
CAT5 or higher:
Connect CAT5 or higher to connector marked [RJ45 IN]
(Fig. 2, pg. 3)
.
3.
eBridge100ST installation:
a. Secure unit to desired mounting surface with a proper fastening device utilizing the case’s mounting hole
(Fig. 3, pg. 3)
. Unit should be mounted in proximity of camera/device.
b. Connect structured cable from IP camera/device to RJ45 jack marked [PoE Out]
(Fig. 3, pg. 3)
.
c.
Coax:
Connect Coax cable to BNC flying lead marked [Coax]
(Fig. 3, pg. 3)
.
Note:
The eBridge100RMT is designed to accommodate Megapixel, HD720, HD1080 and VGA (SD) cameras.
It is important to note that some high resolution and high frame rate cameras may demand faster headend
processing ability, such as a PC graphics card to present a quality image. If the headend processing equipment
is insufficient in speed, the image may show pixilation and latency. It is advisable to pretest system if unsure.
Alternatively, frame rate and resolution may be reduced to accommodate system equipment.
Technical Specifications:
Parameter
Description
Connections
BNC for Coax link. RJ45 for extended Ethernet link.
Input Power
Requirements
Midspan or endspan port connected. PoE compliant to IEEE 802.3af (15W) and
PoE+ compliant to IEEE 802.3at (30W).
Indicators
Yellow (RJ45 connector):
On - Link, Off - No Link, Blinking - Activity.
Green (RJ45 connector):
On - 100Base-TX, Off - 10Base-T.
Green:
PoE Active.
Environmental
Conditions
Operating Ambient Temperature (UL60950-1):
eBridge100RM:
– 20ºC to 49ºC (– 4ºF to 120.2ºF).
eBridge100TM:
– 20ºC to 49ºC (-4ºF to 120.2ºF).
eBridge100ST:
For 15W:
– 40ºC to 75ºC (– 40ºF to 167ºF).
For 30W:
– 40ºC to 60ºC (– 40ºF to 140ºF).
Relative humidity:
85% +/– 5%
Storage Temperature:
– 30ºC to 70ºC (– 22ºF to 158ºF).
Operating Altitude:
– 304.8 to 2,000m.
Regulatory
Compliance
UL/cUL Listed for Information Technology Equipment (UL 60950-1).
CE European Conformity. C-Tick compliant.
Weights (approx.)
Product: 0.25 lbs. (0.11 kg) | Shipping: 0.4 lbs. (0.18 kg).