Overview:

These Altronix DC CCTV Power Supplies provide 6-15VDC distributed via fuse or PTC protected outputs for powering
CCTV Cameras, heaters and other video accessories.

ALTV615DCUL Reference Chart:

ALTV615DC44ULM

4 amp  6-15VDC

4

-

x

x

3.5 amp

0.9 amp

ALTV615DC44ULCBM

4 amp  6-15VDC

4

x

x

-

2.5 amp

0.9 amp

ALTV615DC48ULM

4 amp  6-15VDC

8

-

x

x

3.5 amp

0.9 amp

ALTV615DC48ULCBM

4 amp  6-15VDC

8

x

x

-

2.5 amp

0.9 amp

ALTV615DC416UL 

4 amp  6-15VDC

16

-

x

x

3.5 amp

0.9 amp

ALTV615DC416ULCB

4 amp  6-15VDC

16

x

x

-

2.5 amp

0.9 amp

ALTV615DC616UL

6 amp  6-15VDC

16

-

-

x

3.5 amp

1.5 amp

ALTV615DC616ULCB

6 amp  6-15VDC

16

x

x

-

2.5 amp

1.5 amp

ALTV615DC416ULCBM*

4 amp  6-15VDC

16

x

x

-

2.5 amp

0.9 amp

* Same except for enclosure size.

Specifications:

Caution: This installation should be made by qualified service personnel and should conform to all local
codes and in accordance with the National Electrical Code.

Installation Instructions:

1. Mount unit in desired location.
2. Remove Power Distribution Module and isolation barrier (models with “M” suffix only).
3. Connect AC power to the two black and two white flying leads of the transformer 

(Figs. 1-4, pgs. 4-6).

Units with linecord installed skip Instruction #3.

Use 18 AWG or larger for all power connections. Connect green ground lead to earth ground

(Fig. 1-4, pgs. 4-6).

Keep power limited wiring separate from non-power limited wiring. Minimum .25” spacing must be provided.
Use separate knockouts.

4. Adjust output voltage (unit is factory set at 12VDC): use the trimpot on the power supply board 

prior to connecting CCTV devices.

5. Measure output voltage before connecting devices. This helps avoid potential damage.

CAUTION:

Determine the maximum operating voltage of the equipment being powered before adjusting the 

output voltage.

6. Reinstall isolation barrier and Power Distribution Module (models with “M” suffix only).

Altronix 
Model Number

Output

 Cur

rent

(max per output)

Total Output Cur

rent

(P

ow

er)

Output 

V

oltage

115V

A

C

50/60Hz Input

Cur

rent

PTC Protected

Outputs

Fuse Protected

Outputs

- 2 -

Number

 of 

Outputs

Class 2 Rated

Po

w

er Limited

• UL Listed for Commercial CCTV Equipment (UL 2044).

CUL Listed - CSA Standard C22.2 No.1-98, Audio, 
Video and Similar Equipment.

• Four (4), eight (8), or sixteen (16) individual outputs.
• Filtered and electronically regulated outputs.
• Short circuit and thermal overload protection.
• Unit maintains camera synchronization.

• Ease of installation saves time & eliminates costly labor.
• Spare fuses included (on fuse protected models).

Enclosure Dimensions:

ALTV615DC44ULM, ALTV615DC44ULCBM,
ALTV615DC48ULM, ALTV615DC48ULCBM, and
ALTV615DC416ULCBM: 8.5”H x 7.5”W x 3.75”D
All other models: 13”H x 13.5”W x 3.25”D

Содержание ALTV615DC44ULM

Страница 1: ...rotected Outputs Eight 8 PTC Protected Outputs ALTV615DC416UL ALTV615DC416ULCB 6 15VDC 4 amp 6 15VDC 4 amp Sixteen 16 Fuse Protected Outputs Sixteen 16 PTC Protected Outputs ALTV615DC616UL ALTV615DC61...

Страница 2: ...4 pgs 4 6 Keep power limited wiring separate from non power limited wiring Minimum 25 spacing must be provided Use separate knockouts 4 Adjust output voltage unit is factory set at 12VDC use the trimp...

Страница 3: ...ion Module 1P 4P Positive DC outputs 1N 4N Negative DC outputs PD8UL PD8ULCB Distribution Module 1P 8P Positive DC outputs 1N 8N Negative DC outputs PD16W PD16WCB PD16CB Distribution Module 1P 16P Pos...

Страница 4: ...Wiring Green Lead ground Barrier INPUT 1P 1N 2P 2N 3P 3N 4P 4N LED 1P 2P 3P 4P FUSED OUTPUTS 1N 2N 3N 4N COMMON OUTPUTS 3 5A 250V 3 5A 250V 3 5A 250V MAIN FUSE ON OFF ON OFF Fig 1 ALTV615DC44ULM ALTV6...

Страница 5: ...ted outputs P N N P S XFMR Input PD16W 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 N P Wire Strap from Enclosure to Door non power limited XFMR XFMR Black Lead White Lead 115VAC input 50 60 Hz Power Supply...

Страница 6: ...input 50 60 Hz XFMR Power Supply Board Trimpot DC Outputs Class 2 Power Limited Output Wiring CAUTION De energize unit prior to servicing Do not expose unit to rain or moisture Green Lead ground Barri...

Страница 7: ...25 0 9375 0 9375 1 40 4 85 4 85 1 40 1 20 Bottom Top Right Left 7 Enclosure Dimensions for ALTV615DC44ULM ALTV615DC44ULCBM ALTV615DC48ULM ALTV615DC48ULCBM ALTV615DC416ULCBM 8 5 H x 7 5 W x 3 5 D Enclo...

Страница 8: ...klyn New York 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A II1ALTV615DCULSeries I14F MEMBER Altronix is not responsible fo...

Отзывы: