7.  Set main switch to the OFF position (Fig. 1-4, pgs. 4-5).
8.

  Connect devices to terminals marked [1P - 1N through 4P - 4N] on PD4/PD4CB board, carefully observing 

 

correct polarity (Fig. 1-4, pgs. 4-5).

9.  Set main switch to the “RESET” (ON) position (Fig. 1-4, pgs. 4-5).
10.  Green LED will illuminate when unit is powered.
11.  Upon completion of the wiring, secure enclosure door with screws (supplied).
CAUTION: 

Equipment to be installed/serviced by authorized/trained personnel only. 

 

 

Shut branch circuit power before installing/servicing equipment.

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. 
This installation should be made by qualified service personnel and should conform to the National 
Electrical Code and all local codes.

Terminal Identification:

PD4/PD4CB - Distribution Module

Terminal Legend

Function/Description

1P - 4P

Positive AC output.

1N - 4N

Negative AC output.

The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient
magnitude to constitute an electric shock.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important 
operating and maintenance (servicing) instructions in the literature accompanying the appliance.

CAUTION: To reduce the risk of electric shock do not open enclosure. 
There are no user serviceable parts inside. Refer servicing to qualified 
service personnel.

Содержание ALTV244220

Страница 1: ...Fuse Protected Outputs Four 4 PTC Protected Outputs ALTV244175220 ALTV244175CB220 24VAC 7 25 amp 175VA 24VAC 7 25 amp 175VA or 28VAC 6 25 amp or 28VAC 6 25 amp Four 4 Fuse Protected Outputs Four 4 PT...

Страница 2: ...fasteners Place the enclosure s upper keyholes over the two upper screws Install the two lower screws and make sure to tighten all screws Enclosure Dimensions pg 6 7 Secure enclosure to earth ground...

Страница 3: ...by qualified service personnel and should conform to the National Electrical Code and all local codes Terminal Identification PD4 PD4CB Distribution Module Terminal Legend Function Description 1P 4P...

Страница 4: ...50 60 Hz 4 ALTV244220series ALTV244220 ALTV244175220 F1 F2 F3 F4 INPUT 1P 1N 2P 2N 3P 3N 4P 4N LED MAIN FUSE N P 1P 2P 3P 4P FUSED OUTPUTS 1N 2N 3N 4N COMMON OUTPUTS S N XFMR 24VAC or 28VAC fused outp...

Страница 5: ...th power supply board ALTV244220series 5 ALTV244300220 Transformer underneath power supply board Power Switch F1 F2 F3 F4 INPUT 1P 1N 2P 2N 3P 3N 4P 4N LED N P 1P 2P 3P 4P FUSED OUTPUTS 1N 2N 3N 4N CO...

Страница 6: ...mm x 88 9mm 1 25 31 75mm 1 25 31 75mm 1 25 31 75mm 1 125 28 575mm 1 25 4mm 1 25 4mm 1 25 4mm 5 25 133 35mm 6 05 153 67mm 6 05 153 67mm 3 5 88 9mm 3 5 88 9mm 7 25 184 15mm 2 50 8mm 2 50 8mm 8 125 206 3...

Страница 7: ...9mm x 191mm x 95mm 3 63 92 2mm 7 25 184 15mm 7 25 184 15mm 1 25 4mm 1 25 4mm 1 25 4mm 1 75 44 45mm 8 13 206 5mm 8 13 206 5mm 3 85 97 79mm 1 25 4mm 1 25 4mm 1 25 4mm 3 85 97 79mm 1 25 4mm 1 25 31 75mm...

Страница 8: ...responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A II...

Отзывы: