ALTV244220 Series 

- 3 -

5.  Slide switch SW1 to the ON position on models ALTV244220 and ALTV244CB220 (Fig. 1, pg. 4)
 

Turn main switch on all other models to the “RESET” (ON) position (Figs. 2, 3, pgs. 5, 6).

6.  Measure output voltage before connecting devices. This helps avoiding potential damage.
 

CAUTION: Determine the maximum operating voltage of the equipment being powered before 

 

adjusting the output voltage.

7.  Slide switch SW1 to the OFF position on models ALTV244220 and ALTV244CB220 (Fig. 1, pg. 4)
 

Turn main switch on all other models to the OFF position (Figs. 2, 3, pgs. 5, 6).

8.  Connect devices to the terminals marked [1P - 1N] through [4P - 4N] on PD4/PD4CB board, carefully 
 

observing correct polarity (Figs. 1 - 3, pgs. 4 - 6).

9.  Slide switch SW1 to ON position on models ALTV244 and ALTV244CB (Fig. 1, pg. 4)
 

Turn main switch on all other models to the “RESET” (ON) position (Figs. 2, 3, pgs. 5, 6).

10.  Green LED will illuminate when unit is powered.
11.  Upon completion of the wiring, secure enclosure door with screws (supplied).

CAUTION: Equipment to be installed / serviced by authorized / trained personnel only. 
Shut branch circuit power before installing / servicing equipment.

Troubleshooting:

1.  Blown fuse (ALTV244220, ALTV244175220, ALTV244300220) - Set ON/OFF switch to the OFF position. 
 

Replace the blown fuse(s) with fuse(s) rated @ 3.5A/250VA (Altronix model # Fuse1).

2.  Tripped PTC (ALTV244CB220, ALTV244175CB220, ALTV244300CB220) - To reset PTC set ON/OFF 
 

switch to the OFF position. After approximately 30 secs. set ON/OFF switch to the ON position.

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. 
This installation should be made by qualified service personnel and should conform to the National 
Electrical Code and all local codes.

Terminal Identification:

PD4/PD4CB - Distribution Module

1P - 4P

AC output.

1N - 4N

AC output.

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user 
to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may 
be of sufficient magnitude to constitute an electric shock.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of 
important operating and maintenance (servicing) instructions in the literature accompanying 
the appliance.

CAUTION: To reduce the risk of electric shock do not open 
enclosure. There are no user serviceable parts inside. Refer servicing 
to qualified service personnel.

Содержание ALTV244220 Series

Страница 1: ...100VA Four 4 Fuse Protected Outputs Four 4 PTC Protected Outputs ALTV244175220 ALTV244175CB220 24VAC 7 25A 175VA or 24VAC 7 25A 175VA or or 28VAC 6 25A 175VA 28VAC 6 25A 175VA Four 4 Fuse Protected Outputs Four 4 PTC Protected Outputs ALTV244300220 ALTV244300CB220 24VAC 12 5A 300VA or 24VAC 12 5A 300VA or 28VAC 10A 300VA 28VAC 10A 300VA Four 4 Fuse Protected Outputs Four 4 PTC Protected Outputs ...

Страница 2: ...rews Enclosure Dimensions pg 7 8 Secure enclosure to earth ground 2 Slide switch SW1 to the OFF position on models ALTV244220 and ALTV244CB220 Fig 1 pg 4 Turn main switch on all other models to the OFF position Figs 2 3 pgs 5 6 3 All units are factory set for 24VAC operation For 28VAC operation adjust unit prior to mounting and applying power as follows Change the wire position so that the black w...

Страница 3: ...ng equipment Troubleshooting 1 Blown fuse ALTV244220 ALTV244175220 ALTV244300220 Set ON OFF switch to the OFF position Replace the blown fuse s with fuse s rated 3 5A 250VA Altronix model Fuse1 2 Tripped PTC ALTV244CB220 ALTV244175CB220 ALTV244300CB220 To reset PTC set ON OFF switch to the OFF position After approximately 30 secs set ON OFF switch to the ON position WARNING To reduce the risk of f...

Страница 4: ...0 5A 1A 250V PTC used on ALTV244CB220 1P 1N 2P 2N 3P 3N 4P 4N POWER DISTRIBUTING UNIT PD4A MAIN FUSE INPUT ON OFF Fig 1 ALTV244220 and ALTV244CB220 N P S N P S 24VAC Output Yellow Black Black Yellow 28VAC Output Voltage Selection Configuration ...

Страница 5: ...V Illuminated Power Switch 1P 1N 2P 2N 3P 3N 4P 4N POWER DISTRIBUTING UNIT PD4A MAIN FUSE PTC used on ALTV244175CB220 Fig 2 ALTV244175220 and ALTV244175CB220 N P S N P S 24VAC Output Yellow Black Black Yellow 28VAC Output Voltage Selection Configuration ...

Страница 6: ...300CB220 Input 220VAC 50 60Hz 1 8A 4A 250V 1P 1N 2P 2N 3P 3N 4P 4N POWER DISTRIBUTING UNIT PD4A MAIN FUSE Illuminated Power Switch PTC used on ALTV244300CB220 N P S N P S 24VAC Output Yellow Black Black Yellow 28VAC Output Voltage Selection Configuration ...

Страница 7: ... 190 5mm x 88 9mm 1 25 31 75mm 1 25 31 75mm 1 25 31 75mm 1 125 28 575mm 1 25 4mm 1 25 4mm 1 25 4mm 5 25 133 35mm 6 05 153 67mm 6 05 153 67mm 3 5 88 9mm 3 5 88 9mm 7 25 184 15mm 2 50 8mm 2 50 8mm 8 125 206 375mm 0 6 15 24mm 1 25 4mm 1 25 4mm 0 6 15 24mm 0 6 15 24mm 1 125 28 575mm 0 6 15 24mm 3 625 184 15mm ...

Страница 8: ...ies E08R MEMBER Enclosure Dimensions H x W x D for ALTV244175220 ALTV244175CB220 ALTV244300220 ALTV244300CB220 8 5 x 7 5 x 3 875 215 9mm x 191mm x 98 4mm 3 63 92 2mm 7 25 184 15mm 7 25 184 15mm 1 25 4mm 1 25 4mm 1 25 4mm 1 75 44 45mm 8 13 206 5mm 8 13 206 5mm 3 85 97 79mm 1 25 4mm 1 25 4mm 1 25 4mm 3 85 97 79mm 1 25 4mm 1 25 31 75mm 1 25 31 75mm 1 25 31 75mm 1 25 31 75mm 3 85 97 79mm 0 6 15 24mm 0...

Отзывы: