Overview:

Altronix ALTV244220 Series CCTV Power Supplies provide 24VAC or 28VAC distributed via four (4) fuse or 
PTC protected outputs for powering CCTV cameras, heaters and other video accessories.

Four (4) Output ALTV244 Reference Chart:

Altronix 
Model Number

Total

 Output

Current

Output

Voltage

Number of

Outputs

PTC Protected

Outputs

(auto-resettable)

Fuse Protected

Outputs

Output Current

(max per output)

Main

Fuse Ratings

220VAC

50/60Hz

Input Current

ALTV244220

4A

24VAC

4

P

3.5A

5A/

250V

0.5A

3.5A

28VAC

ALTV244CB220

4A

24VAC

P

2.5A

3.5A

28VAC

ALTV244175220

7.25A

24VAC

P

3.5A

10A/

250V

0.8A

6.25A

28VAC

ALTV244175CB220

7.25A

24VAC

P

2.5A

6.25A

28VAC

ALTV244300220

12.5A

24VAC

P

3.5A

15A/

32V

1.8A

10A

28VAC

ALTV244300CB220

10A

24VAC

P

2.5A

10A

28VAC

Specifications:

Installation Instructions:

1.  Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes 
 

in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place 

 

the enclosure’s upper keyholes over the two upper screws; level and secure. Mark the position of the lower 

 

two holes. Remove the enclosure. Drill the lower holes and install the fasteners. Place the enclosure’s upper 

 

keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws 

 

(Enclosure Dimensions, pg. 7, 8). Secure enclosure to earth ground. 

2.  Slide switch SW1 to the OFF position on models ALTV244220 and ALTV244CB220 (Fig. 1, pg. 4)
 

Turn main switch on all other models to the OFF position (Figs. 2, 3, pgs. 5, 6).

3.  All units are factory set for 24VAC operation.
 

For 28VAC operation adjust unit prior to mounting and applying power as follows: Change the wire position 

 

so that the black wire [28V] is connected to the terminal marked [P] and the yellow wire [24V] is connected 

 

to the terminal marked [S].

4.  Connect unswitched AC circuit (220VAC, 50/60Hz) as follows: Green branch wire (ground) connects to the 
 

terminal marked     , Line connects to the terminal marked [L], and Neutral connects to the terminal marked 

 

[N] of the Inlet Appliance Connector. (Figs. 1-3, pgs. 4-6).

  

Use 18 AWG or larger for all power connections (Battery, AC output).

Agency Listing:

•  CE European Conformity.

Input:

•  220VAC (working range 198VAC - 256VAC), 
 50/60Hz.

Output:

•  Four (4) fuse or PTC protected outputs. 
•  24VAC or 28VAC supply current.
•  Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
•  Surge suppression.

Features:

•  Slow blow main fuse on power distribution board.
•  AC power LED.
•  Power ON/OFF switch.
•  Spare fuses provided.
  (all models w/primary and/or secondary fuses).

Enclosure Dimensions:

•  ALTV244220 and ALTV244CB220:
 8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm).
•  ALTV244175220, ALTV244175CB220, 
  ALTV244300220, and ALTV244300CB220:
  8.5” x 7.5” x 3.875” (215.9mm x 191mm x 98.4mm).

Input

220VAC
50/60Hz,

0.5A

1A

250V

PTC 

used on

ALTV244CB220

1P 1N  2P  2N     3P 3N  4P  4N

POWER DISTRIBUTING UNIT

PD4A

MAIN FUSE

INPUT

ON    OFF

Содержание ALTV244220 Series

Страница 1: ...100VA Four 4 Fuse Protected Outputs Four 4 PTC Protected Outputs ALTV244175220 ALTV244175CB220 24VAC 7 25A 175VA or 24VAC 7 25A 175VA or or 28VAC 6 25A 175VA 28VAC 6 25A 175VA Four 4 Fuse Protected Outputs Four 4 PTC Protected Outputs ALTV244300220 ALTV244300CB220 24VAC 12 5A 300VA or 24VAC 12 5A 300VA or 28VAC 10A 300VA 28VAC 10A 300VA Four 4 Fuse Protected Outputs Four 4 PTC Protected Outputs ...

Страница 2: ...rews Enclosure Dimensions pg 7 8 Secure enclosure to earth ground 2 Slide switch SW1 to the OFF position on models ALTV244220 and ALTV244CB220 Fig 1 pg 4 Turn main switch on all other models to the OFF position Figs 2 3 pgs 5 6 3 All units are factory set for 24VAC operation For 28VAC operation adjust unit prior to mounting and applying power as follows Change the wire position so that the black w...

Страница 3: ...ng equipment Troubleshooting 1 Blown fuse ALTV244220 ALTV244175220 ALTV244300220 Set ON OFF switch to the OFF position Replace the blown fuse s with fuse s rated 3 5A 250VA Altronix model Fuse1 2 Tripped PTC ALTV244CB220 ALTV244175CB220 ALTV244300CB220 To reset PTC set ON OFF switch to the OFF position After approximately 30 secs set ON OFF switch to the ON position WARNING To reduce the risk of f...

Страница 4: ...0 5A 1A 250V PTC used on ALTV244CB220 1P 1N 2P 2N 3P 3N 4P 4N POWER DISTRIBUTING UNIT PD4A MAIN FUSE INPUT ON OFF Fig 1 ALTV244220 and ALTV244CB220 N P S N P S 24VAC Output Yellow Black Black Yellow 28VAC Output Voltage Selection Configuration ...

Страница 5: ...V Illuminated Power Switch 1P 1N 2P 2N 3P 3N 4P 4N POWER DISTRIBUTING UNIT PD4A MAIN FUSE PTC used on ALTV244175CB220 Fig 2 ALTV244175220 and ALTV244175CB220 N P S N P S 24VAC Output Yellow Black Black Yellow 28VAC Output Voltage Selection Configuration ...

Страница 6: ...300CB220 Input 220VAC 50 60Hz 1 8A 4A 250V 1P 1N 2P 2N 3P 3N 4P 4N POWER DISTRIBUTING UNIT PD4A MAIN FUSE Illuminated Power Switch PTC used on ALTV244300CB220 N P S N P S 24VAC Output Yellow Black Black Yellow 28VAC Output Voltage Selection Configuration ...

Страница 7: ... 190 5mm x 88 9mm 1 25 31 75mm 1 25 31 75mm 1 25 31 75mm 1 125 28 575mm 1 25 4mm 1 25 4mm 1 25 4mm 5 25 133 35mm 6 05 153 67mm 6 05 153 67mm 3 5 88 9mm 3 5 88 9mm 7 25 184 15mm 2 50 8mm 2 50 8mm 8 125 206 375mm 0 6 15 24mm 1 25 4mm 1 25 4mm 0 6 15 24mm 0 6 15 24mm 1 125 28 575mm 0 6 15 24mm 3 625 184 15mm ...

Страница 8: ...ies E08R MEMBER Enclosure Dimensions H x W x D for ALTV244175220 ALTV244175CB220 ALTV244300220 ALTV244300CB220 8 5 x 7 5 x 3 875 215 9mm x 191mm x 98 4mm 3 63 92 2mm 7 25 184 15mm 7 25 184 15mm 1 25 4mm 1 25 4mm 1 25 4mm 1 75 44 45mm 8 13 206 5mm 8 13 206 5mm 3 85 97 79mm 1 25 4mm 1 25 4mm 1 25 4mm 3 85 97 79mm 1 25 4mm 1 25 31 75mm 1 25 31 75mm 1 25 31 75mm 1 25 31 75mm 3 85 97 79mm 0 6 15 24mm 0...

Отзывы: