- 8 - 

AL602ADA220 Installation Guide

  

SW1

-- 

 DC  

+

 

SW2

+ OUT1 

--

OUT1 

 OUT2 

 OUT3 

 OUT4

INP1 

INP2 

FAULT

         

         

         

         

NC

C

NO

C  "FAULT"  NC

OUT1

OUT3

OUT2

OUT4

INPUT SELECT

TEMPORAL

STROBE SYNC IN > OUT SYNC 

IN1+

IN1

--

IN2

--

IN2+

C "DR

Y1" NC

RET1+

RET1

--

RET2

--

RET2+

C "DR

Y2" NC

+ OUT2 

--

+ OUT3 

--

+ OUT4 

--

INPUT SELECT

TEMPORAL

STROBE SYNC IN > OUT SYNC 

-- 

 AUX  

+

UPPER TERMINALS

LOWER TERMINALS

line

neutral

RESET

Unswitched 220VAC

power mains 

(non-power limited)

5A

250V

ON

1

ON

1

Ground

Ground

Lug

Supervised

Non-power limited

Supervised

Non-power limited

Use separate knockout. Keep 0.25" spacing from  non power-limited wiring 

Compatible Special  Application Devices. See Compatibility List

Non-Supervised Class 

E

Addressable Control Module Trigger Output

Non-Supervised Class E Power-Limited

Regulated Power-Limited

Supervised Outputs 

2.5A max. per output in alarm 

(total= 6.5A)

Supervised

Power-Limited

Digital Communicator or Local Annunciator Dry output Contact (Form "C" contacts). Connection to triggering devices must be  made within 20 ft. of distance and using  conduit for wiring.

This connection is used to monitor AC and Bat Fail and will cause a simultaneous trouble  condition to the FACP's IN1 and IN2

Non-Supervised Class 

E

AC Local

Power-limited

Fig. 2a

  

SW1

-- 

 DC  

+

 

SW2

+ OUT1 

--

OUT1 

 

OUT2 

 

OUT3 

 

OUT4

INP1 

INP2 

FAULT

         

         

         

         

NC

C

NO

C  "FAULT"  NC

OUT1

OUT3

OUT2

OUT4

INPUT SELECT

TEMPORAL

STROBE SYNC IN > OUT SYNC 

IN1+

IN1

--

IN2

--

IN2+

C "DR

Y1" NC

RET1+

RET1

--

RET2

--

RET2+

C "DR

Y2" NC

+ OUT2 

--

+ OUT3 

--

+ OUT4 

--

INPUT SELECT

TEMPORAL

STROBE SYNC IN > OUT SYNC 

-- 

 AUX  

+

UPPER TERMINALS

LOWER TERMINALS

line

neutral

RESET

Unswitched 220VAC

power mains 

(non-power limited)

5A

250V

ON

1

ON

1

Ground

Ground

Lug

Supervised

Non-power limited

Supervised

Non-power limited

Use separate knockout. Keep 0.25" spacing from  non power-limited wiring 

Compatible Special  Application Devices. See Compatibility List

Non-Supervised Class 

E

Addressable Control Module Trigger Output

Non-Supervised Class E Power-Limited

Regulated Power-Limited

Supervised Outputs 

2.5A max. per output in alarm 

(total= 6.5A)

Supervised

Power-Limited

Digital Communicator or Local Annunciator Dry output Contact (Form "C" contacts). Connection to triggering devices must be  made within 20 ft. of distance and using  conduit for wiring.

This connection is used to monitor AC and Bat Fail and will cause a simultaneous trouble  condition to the FACP's IN1 and IN2

Non-Supervised Class 

E

AC Local

Power-limited

Fig. 2b

Common trouble Input/Output

Fig. 2c

Trouble Memory Reset Button

  

SW1

-- 

 DC  

+

 

SW2

+ OUT1 

--

OUT1 

 OUT2 

 OUT3 

 OUT4

INP1 

INP2 

FAULT

         

         

         

         

NC

C

NO

C  "FAULT"  NC

OUT1

OUT3

OUT2

OUT4

INPUT SELECT

TEMPORAL

STROBE SYNC IN > OUT SYNC 

IN1+

IN1

--

IN2

--

IN2+

C "DR

Y1" NC

RET1+

RET1

--

RET2

--

RET2+

C "DR

Y2" NC

+ OUT2 

--

+ OUT3 

--

+ OUT4 

--

INPUT SELECT

TEMPORAL

STROBE SYNC IN > OUT SYNC 

-- 

 AUX  

+

UPPER TERMINALS

LOWER TERMINALS

line

neutral

RESET

Unswitched 220VAC

power mains 

(non-power limited)

5A

250V

ON

1

ON

1

Ground

Ground

Lug

Supervised

Non-power limited

Supervised

Non-power limited

Use separate knockout. Keep 0.25" spacing from  non power-limited wiring 

Compatible Special  Application Devices. See Compatibility List

Non-Supervised Class 

E

Addressable Control Module Trigger Output

Non-Supervised Class E Power-Limited

Regulated Power-Limited

Supervised Outputs 

2.5A max. per output in alarm 

(total= 6.5A)

Supervised

Power-Limited

Digital Communicator or Local Annunciator Dry output Contact (Form "C" contacts). Connection to triggering devices must be  made within 20 ft. of distance and using  conduit for wiring.

This connection is used to monitor AC and Bat Fail and will cause a simultaneous trouble  condition to the FACP's IN1 and IN2

Non-Supervised Class 

E

AC Local

Power-limited

Hookup 

Diagram:

Fig. 2

NC

C

NO

C "FAULT" NC

Содержание AL602ADA220

Страница 1: ...ee Application Guide for additional information Rev 030320 More than just power TM Installing Company ________________ Service Rep Name ___________________________________ Address ______________________________________________ Phone ___________________ ...

Страница 2: ...ersonnel and should conform to all local codes Input Nominal 220VAC working range 198 256VAC 60Hz 1 2A Two 2 Class A or two 2 Class B FACP inputs Two 2 NC dry contact trigger inputs Output 24VDC 6 5A max total alarm current 2 5A max current per output Separate 1 0A auxiliary output Programmable supervised indicating circuit outputs Four 4 Class B or two 2 Class A or One 1 Class A and Two 2 Class B...

Страница 3: ...02ADA220 AL1002ADA220 Power Supply Specifications pg 3 Stand by Specifications pg 3 Output Programming Selection Table pg 4 Sync Mode Selection Table pg 4 Terminal Identification Table pgs 5 6 LED Status Indication Table pg 6 1 Mount the unit in the desired location Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure Install two upper fasteners and screws in t...

Страница 4: ...connected Sync Mode Selection Table Function Switch Positions Descriptions ON OFF Amseco Sync Mode 1 3 4 2 This mode is designed to work with the Amseco series of horns strobes and horn strobes to provide a means of synchronizing the Temporal coded horns synchronizing the flash timing of the strobe and silencing the horns of the horn strobe combination over a two wire circuit while leaving strobes...

Страница 5: ...puts are set by output switches OUT1 through OUT4 Output Programming Selection Table pg 4 Note these inputs are unidirectional and will not report a trouble condition to the FACP OUT1 OUT2 OUT3 OUT4 Supervised Notification appliances are connected to these regulated outputs see 02 Application Guide pg 2 4 Each power limited output will supply 2 5A Total supply current is 6 5A see note below Output...

Страница 6: ...s Low battery condition will report at approximately 21VDC Battery presence detection will report with in 180 seconds after battery remains undetected missing or removed A restored battery will report within 30 seconds LED Diagnostics AL600ADA Power Supply Board Red DC Green AC Power Supply Status ON ON Normal operating condition ON OFF Loss of AC Stand by battery is supplying power OFF ON No DC o...

Страница 7: ...larm mA 0mA mA Alarm mA 0mA mA Alarm mA 0mA mA Alarm mA 0mA mA C Notification Appliances Current must not exceed 6 5A 6500mA 0mA mA D Total alarm current mA mA E Total current ratings converted to amperes line D x 0 001 A A F Number of standby hours 24 for NFPA 72 Chapter 1 1 5 2 5 H G Multiply lines E and F Total stand by AH AH H Alarm sounding period in hours For example 5 minutes 0 0833 hours H...

Страница 8: ... a simultaneous trouble condition to the FACP s IN1 and IN2 Non Supervised Class E AC Local Power limited Fig 2a DC OUT1 OUT2 OUT3 OUT INP1 INP2 F OUT1 OUT3 OUT2 OUT4 INPUT SELECT TEMPORAL STROBE SYNC IN OUT SYNC INPUT SELECT TEMPORAL STROBE SYNC IN OUT SYNC AUX line neutral RESET Unswitched 220VAC power mains non power limited 5A 250V Use separate knockout Keep 0 25 spacin non power limited wirin...

Страница 9: ... C should connect to the host control panel for local annunciation of the trouble condition Note If common trouble input terminals marked C FAULT NC are not used these terminals must be shorted connect jumper to remain inactive For optional hookups see Fig 2b Maintenance Unit should be tested at least once a year for the proper operation as follows Output Voltage Test Under normal load conditions ...

Страница 10: ...ystem Sensor 2112 24AITR Photoelectric 0 50 60 70 System Sensor 2112 24 D Photoelectric 0 05 50 System Sensor 2112 24R Photoelectric 0 50 60 70 System Sensor 2112 24TR Photoelectric 0 50 60 70 System Sensor 2112 24T D Photoelectric w 135 o Thermal 0 05 50 System Sensor 2112 24TSRB Photoelectric w 135 o Thermal Supervisory Relay 15 45 System Sensor 2312 24TB Photoelectric 0 12 50 System Sensor 2412...

Страница 11: ...ount 96 Rixon Firemark FM 980 Floor Mount single 68 Rixon Firemark FM 996 Surface Wiring 68 Rixon Firemark FM 998 Concealed Wiring 68 A 3 Relays Table A 3 below lists relays compatible with AL602ADA220 AUX output and Outputs 1 8 when programmed as AUX Manufacturer Model Current mA Manufacturer Model Current mA System Sensor PR 1 15 System Sensor R 20T 40 PR 2 30 R 24T 40 PR 3 30 R 10E 23 EOLR 1 30...

Страница 12: ...25 31 8mm 1 25 31 8mm 0 79 20 1mm 0 91 23 1mm 0 91 23 1mm 15 5 393 7mm 1 1 27 9mm 1 1 27 9mm 1 1 27 9mm 12 23 310 6mm 2 0 50 8mm 2 0 50 8mm 1 25 31 8mm 1 25 31 8mm Enclosure Dimensions 15 5 x 12 x 4 5 393 7mm x 304 8mm x 114 3mm Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 website www altronix com e mail in...

Отзывы: